| All call and group call | 20/40/60/80 call capacity |
|---|
| Call log | Large variety of sub stations |
|---|
| Powerful sound | Durability and reliability NURSE CALL SYSTEM NURSE CALL SYSTEM Provides reliable communication and enhances the quality of care. |
|---|
| Individual communication | Call history can be |
|---|
| with patients is possible by | traced and analysed |
|---|
| using the bedside handheld | by PC. sub station. COMMUNICATION SYSTEM Used in a wide range of environments such as highway toll gates and schools. COMMUNICATION SYSTEM |
|---|
| Outdoor sub station | Broadcast option is |
|---|
| and newly designed | available. indoor sub station. Necessary communication for healthcare facilities. < Examples of System Configuration > NIM can be used as a nurse call system for providing calls from patient rooms and bathrooms to nurse Various system configurations offer application flexibility and sophistication. PC connection makes it possible to check call history. Single bed communication (bedside handheld su |
|---|
| Bedside handheld | Wall jack with call button Corridor light with Bedside Wall jack with |
|---|
| sub station | hanger for NI-RC with pull cord nameplates, 4 names call switch microphone for NIR-8 |
|---|
| NI-RC | NIR-HPF NIR-7HW NIR-34 NIR-8 NIR-MB |
|---|
| Bedside | Bathroom |
|---|
| handheld | call button |
|---|
| Wall jack with | surface |
|---|
| hanger for NI-RC | mount |
|---|
| NIR-HPF | NI-BA |
|---|
| Corridor light, | Call reset |
|---|
| multiple beds | button |
|---|
| NIR-4S | NIR-2 Private room Page 5. Sub station, |
|---|
| surface | Corridor light Call reset |
|---|
| mount | with buzzer button |
|---|
| NI-BA | NIR-4BZ NIR-2 Outpatient Floor Examination room Page 10. Sub station, surface mount NI-BA Corridor Ceiling NI-LB NURSE CALL SYSTEM |
|---|
| Ceiling | Corridor light, Call reset Bedside Wall jack for Ceiling Ceiling Corridor light, Call reset |
|---|
| speaker | single bed button call switch NIR-8 microphone speaker single bed button |
|---|
| NI-LB | NIR-4 NIR-2 NIR-8 NIR-1 NI-SB NI-LB NIR-4 NIR-2 |
|---|
| Bathroom Page 9. | Nurse station Page 11. Master station, 40-call NIM-40B Corridor light, single bed NIR-4 Call reset |
|---|
| 按鈕 | Power supply |
|---|
| NIR-2 | IS-PU Bathroom call button |
|---|
| with pull cord | Call log software PC |
|---|
| NIR-7HW | NI-SOFT (Third party product) Employee service entrance Page 10. Sub station, flush mount |
|---|
| Outpatient admissions | NI-JA Master station, 20-call NIM-20B General service entrance Page 10. |
|---|
| 供電 | Sub station, flush mount IS-PU NI-JA |
|---|
| NURSE CALL SYSTEM | Single bed communication Personal communication ensures the priv Single bed communication : Communication system using a speaker and a microphone. 3-bed room with bathroom Nurse station Examples of Equipment Application 3-bed room < Installation using bedside handheld sub station > with bathroom |
|---|
| Private room | < Installation using desk mount sub station > Corridor light with buzzer can be used for notification of |
|---|
| calls from patients | Corridor light Call reset |
|---|
| requiring special | with buzzer button |
|---|
| NIR-4BZ | NIR-2 attention. Sub station, surface mount NI-BA Features |
|---|
| Push the call | When a call is received, the indicator blinks to |
|---|
| button. | notify where the call is made from. NURSE CALL SYSTEM |
|---|
| Bedside handheld sub station is used to | calls easily and respond to the patient quickly. communicate with the nurse station. The desk mount sub station can be used for calls and communication also. |
|---|
| Sub station, | Corridor light with |
|---|
| surface mount | nameplates, 4 names |
|---|
| Answering with handset | in green. When receiving two or more calls* |
|---|
| Lift the handset | Push the station selector button |
|---|
| and talk with | to select the desired call.** |
|---|
| the caller. | Then, talk with the caller by using the handset or pressing the TALK button. * Maximum of 10 calls can be received simultaneously. |
|---|
| Lights up in red | POWER ** If this step is skipped, the first-arrived call is POWER Blinks |
|---|
| only when speaking. | automatically selected. in red. Answering in open voice mode RECEIVE VOL. Calling a single sub station |
|---|
| Push and hold TALK to | Push a call selector button to Lights up |
|---|
| begin talking with the | in green. call the desired sub station. |
|---|
| caller. | Then, talk with the caller by |
|---|
| Release TALK to listen. | using the handset or pressing |
|---|
| Lights up in red while | the TALK button. |
|---|
| holding the TALK | Lights up in green. button pressed. |
|---|
| Ceiling microphone | Ceiling speaker |
|---|
| NI-SB | NI-LB |
|---|
| call switch | NIR-8 |
|---|
| NIR-8 | NIR-1 |
|---|
| single bed | button |
|---|
| NIR-4 | NIR-2 4-bed room < Installation using wall jack with microphone and ceiling speaker > Ceiling NI-LB Wall jack with |
|---|
| Push the call button. | When a call is received, the indicator blinks to notify where the call is made from. NURSE CALL SYSTEM CALL Bedside |
|---|
| ceiling microphone. | NIR-4 Ceiling speaker NI-LB The user speaks toward the wall jack and hears the reply from the ceiling speaker. Wall jack with microphone for NIR-8 NIR-MB |
|---|
| Bathroom | Bathroom call button |
|---|
| Nurse | with pull cord |
|---|
| station | Bathroom NIR-7HW Corridor light, single bed NIR-4 Corridor light with buzzer NIR-4BZ Call reset button NIR-2 Features The user pushes the call button or pulls the When a call is received, the indicator blinks to |
|---|
| cord to call for assistance. | notify where the call is made from. The call indicator lights up while calling. Bathroom call button CALL with pull cord NIR-7HW Master station Lighted lamps in corridor enable nurses to notice calls easily and respond to the patient quickly. Buzzer-equipped stations notify Corridor light, |
|---|
| Examination | Outpatient |
|---|
| room | admissions Sub station, surface mount NI-BA General service entrance service entrance Sub station, |
|---|
| Flush mount outdoor station allows | flush mount NI-JA Features |
|---|
| Sub station, surface mount (NI-BA) | Usage examples |
|---|
| Staff rooms and | Bedside |
|---|
| New slim and smart design | common-use areas |
|---|
| Sub station, flush mount (NI-JA) | Usage examples |
|---|
| Courtyards | Communication for visitors Vandalism- and weather-resistant – ideal for outdoor installations |
|---|
| Master station | IS-PU RS-232C cable (Included with NI-SOFT) *To connect the master station with the computer, use the special RS-232C cable that is included with NI-SOFT. Call log software |
|---|
| PC (Third party product) | NI-SOFT * NIM software (NI-SOFT) is needed to manage call histories. Install NI-SOFT on your PC. For more information on PC compatibility see Page 22. Features List and search from call history NURSE CALL SYSTEM Call history can be searched by date, call time, sub station number, etc. Seiji Yokoi, diabetes, check hourly Taylor Wyatt, pneumonia, check daily Isolation room, NO ENTRY Additional infor |
|---|
| COMMUNICATION SYSTEM | Public facilities A communication system specialized for sim < Examples of System Configuration > NIM system can be used for reliable communication. It can also be used in challenging conditions and noisy environments. This opens the door for various business and administrative applications. Example of Installation at a Toll Gate |
|---|
| Office | Staffed toll booth Automated toll gate |
|---|
| Ticket vending machines | Help points Examples of Equipment Application |
|---|
| Large button allows easy operation. | When a call is received, the call indicator blinks |
|---|
| Communication is enabled by a single | to signify which booth is sending the call. push of the button. |
|---|
| CALL | COMMUNICATION SYSTEM TALK |
|---|
| Flush mount sub station is weather- and | Master station vandalism-resistant. For more information on master station use see Page 6. The call indicator on the sub stations provides visual indication of call status. Lit while being called, off during communication. |
|---|
| Hallway | Classroom |
|---|
| Lobby | School gate Staff room |
|---|
| Group broadcasts to selected stations | NIM SYSTEM Broadcasts limited to selected classrooms are possible. Push the station selector button(s) for the target sub station(s). RECEIVE VOL. Entran |
|---|
| ce | Entran The call-in indicator(s) 1-A ce CALL TONE VOL. 3-A for the selected 1-B station(s) blink(s) in 3-B 1-C green. 3-C 1-D 3-D 2-A Hallwa |
|---|
| OFF | ALL CALL TRANSIT 2-B y-A |
|---|
| Hallwa | Group broadcasts can be made to up to 5 sub stations. 2-C y-B Hallwa 2-D y-C Hallwa |
|---|
| GATE | y-D Wareh ouse Upgrade from an existing NEM system. Handheld sub station |
|---|
| Original system (NEM system) | NIM system |
|---|
| Privacy is difficult to | • The handheld sub stations |
|---|
| maintain using ceiling sub | are equipped with a |
|---|
| station. | microphone and speaker, enabling communication with individual patients. • Private communication helps to provide more detailed care of patients. Desk mount sub station |
|---|
| The previous sub station had | • The new sub station is vandalism- and weather- resistant. |
|---|
| limited application scope. | This allows installation in a wider range of areas. IP54 (dust- and moisture-resistant) IK07 (ruggedized against vandalism) |
|---|
| Simple communication | • Connectable to PC for call history, patient information, |
|---|
| without call log. | and call-response data. No need for an Internet connection. Using a RS-232C cable is enough for PC connection. System conf iguration example. Wiring method is subject to system conf iguration. Master station, 40-call NIM-40B Master station, 20-call NIM-20B Ceiling speaker |
|---|
| / 3 NI-LB | /3 NI-LB Ceiling Corridor / 2 /2 Wall jack with |
|---|
| Speaker etc. | NI-SB microphone for (3W/20Ω third party product) light, / 2 / 4 NIR-8 |
|---|
| single | Wall jack for 2 NIR-8 NIR-MB 2 bed |
|---|
| / | NIR-4 / NIR-1 4 |
|---|
| /2 | /2 |
|---|
| Call extension speaker | call switch |
|---|
| Call | /2 NIR-8 IER-2 |
|---|
| 重設 | /4 NIR-8 |
|---|
| Call log software | NIR-1 |
|---|
| NI-SOFT | RS-232C (Included with NI-SOFT) |
|---|
| /4 | NIR-8 NIR-8 |
|---|
| or | NIR-MB |
|---|
| IS-PU | / NIR-6 NIR-8 4 4 3 |
|---|
| Corridor light with | Wall jack |
|---|
| nameplates, 4 names | for NI-RC |
|---|
| NIR-34 | NIR-HP |
|---|
| /3 | /3 /3 Sub station, |
|---|
| NIR-42 | or |
|---|
| NIR-1 | NIR-7HW NIR-42 |
|---|
| NI-JA | (Qty) (Qty) (Qty) |
|---|
| NIM-20B | 1 20 1 1 |
|---|
| Corridor light | /2 NIM-40B 1 40 1 1 |
|---|
| with reset | Wire diameter Maximum distance |
|---|
| button NIR-42 | Ø0.65 mm (22 AWG) 130 m (490’) |
|---|
| Master station - sub station | Ø0.9 mm (19 AWG) 200 m (650’) |
|---|
| Master station - power supply | Ø0.9 mm (19 AWG) 10 m (33’) |
|---|
| Master station - call extension | Ø0.9 mm (19 AWG) 50 m (165’) speaker (IER-2) |
|---|
| Master station, 20-call | Master station, 40-call * NIM-80B Master station, 80-call (special order product) Call button, wall jack |
|---|
| Bedside call switch | Wall jack for NIR-8 Wall jack with Call latching Call button |
|---|
| microphone for NIR-8 | wall jack for NIR-8 |
|---|
| Material: Flame resisting | Power source: Supplied from the Power source: Supplied from the Power source: Supplied from the Power source: Supplied from the |
|---|
| plastic | master station master station master station master station |
|---|
| Mounting: Wall (flush)-mount | Mounting: Wall (flush)-mount Mounting: Wall (flush)-mount Mounting: Wall (flush)-mount |
|---|
| Electrical box: 1-gang box | Electrical box: 1-gang box Electrical box: 1-gang box Electrical box: 1-gang box |
|---|
| Material: Plastic | Material: Plastic Material: Plastic Material: Plastic Sub station |
|---|
| Bedside handheld sub station | Wall jack for NI-RC Wall jack with hanger for NI-RC Power source: Supplied from the master station Power source: Supplied from the master station Power source: Supplied from the master station Communication: Open voice hands-free auto-voice actuation Mounting: Wall (flush)-mount Mounting: Wall (flush)-mount |
|---|
| Ceiling speaker | Ceiling microphone |
|---|
| Sub station, surface mount | Sub station, flush mount |
|---|
| Power source: Supplied from the | Power source: Supplied from the master |
|---|
| master station | station |
|---|
| Communication: Open voice hands-free | Communication: Open voice hands-free |
|---|
| communication | Ceiling speaker Ceiling microphone |
|---|
| Mounting: Desktop use or | Mounting: Flush-mount |
|---|
| wall (surface)-mount | Electrical box: 2-gang box |
|---|
| Mounting: Flush-mount on the ceiling | Mounting: Flush-mount on the ceiling |
|---|
| Material: Flame resisting resin | Main unit: Flame resisting |
|---|
| Corridor light, single bed | Mounting: Wall (flush)-mount nameplate, 1 name Electrical box: 1-gang box |
|---|
| Call reset button | Corridor light with buzzer Corridor light with reset button 4 names |
|---|
| Bathroom call button | Call extension Power supply IS-PU-UL IS-PU-S |
|---|
| NIR-7W | Bathroom call IER-2 Power source: AC 100 - 240 V, 50/60 Hz. |
|---|
| Remarks: Splash proof | Remarks: Splash proof Material: Steel plate (*): IS-RACK: Consult an authorized Aiphone dealer for details. |
|---|
| PC application | System requirements fo PC Windows 7 / Home Premium / Professional / Ultimate(Service Pack1 32/64bit) ・The application may not run or may |
|---|
| OS Windows 8.1/ Pro (32/64bit) | not operate correctly (such as freezes occurring) on a PC with |
|---|
| 處理器 | 2.7 GHz or higher specifications below the necessary |
|---|
| System memory (RAM) 2 GB RAM or higher | requirements. ・We recommend using a PC that |
|---|
| Hard drive | 100 MB or more (Additional space is needed during installation.) exceeds the basic system •RS232C port installed on the PC or an add-in board requirements. •CD-R readable drive |
|---|
| Accessory : RS-232C cable | •Run-time : Microsoft.NET Framework 4.5 Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. UNIT DIMENSIONS (mm) |
|---|
| ø180 | ø105 |
|---|
| NIR-4, NIR-4S | NIR-2 NIR-4BZ NIR-42 NI-BA NI-JA 120 120 120 120 150 120 70 21.5 70 13 116 27 116 27 130 33 |
|---|
| NIR-31 | NIR-32 NIR-34 IS-PU NIR-7W NIR-7HW 144 144 144 265 250 120 120 16 16 16 190 24 190 24 306 24 11 83 70 11 130 70 *A gang box (not included) with a depth of the required value or higher is needed. http://www.aiphone.net/ Deming Medal Printed in Japan ( E ) NB58002BJZ |
|---|