| 機身 | Metal material |
|---|
| 淨重 | 3.2 kg (7.0 lb) |
|---|
| 毛重 | 2.5 kg (5.5 lb) |
|---|
| 尺寸 | 440.0 mm × 44.0 mm × 220.8 mm (17.32'' × 1.73'' × 8.69'') |
|---|
| 工作溫度 | 0 °C to 45 °C (32 °F to 113 °F) |
|---|
| 儲存溫度 | -40 °C to 85 °C (-40 °F to 185 °F) |
|---|
| 工作濕度 | 5% to 95% (no condensation) |
|---|
| 相對濕度 | 5% to 95% (no condensation) |
|---|
| 供電 | 100-240 V AC, 50/60 Hz, Max. 4 A |
|---|
| 最大功耗 | 250 W |
|---|
| 閒置功耗 | 20 W |
|---|
| 防雷 | 6 kV |
|---|
| 安裝方式 | Desk-Mounted,Rack (equipped with mounting ears) |
|---|
| Ports | 16 × Gigabit PoE port,2 × Gigabit RJ45 port,2 × Gigabit fiber optical port |
|---|
| MAC 位址表 | 16 K |
|---|
| 交換容量 | 68 Gbps |
|---|
| 包轉發率 | 50.59 Mpps |
|---|
| 內部緩存 | 8.4 Mbits Ports 1 to 16: up to 300 m. Long range performance may vary depend on camera model or cable condition. Ports 1 to 20: port isolation mode to improve network security |
|---|
| Port Isolation | Ports in an isolation group cannot communicate with each other, but they can communicate with ports outside the isolation group. |
|---|
| PoE Watchdog | Ports 1 to 16: Auto detect and restart the cameras that do not respond. Link aggregation is used to aggregate multiple physical ports to form a logical port for load balancing, bandwidth expansion, and port protection. Support static link aggregation. Support 8 aggregation group(s). QoS is used to allocate bandwidth to different services so as to provide end-to-end service quality assurance. Suppo |
|---|
| VLAN | Configurable VLAN ID from 1-4094. Support Trunk, Access port mode. Support Max. 1024 VLAN. Support one-click activation and remote management via Hik-Partner Pro. Functions supported: 1. Display the port rate. 2. Display the port bandwidth utilization rate. 3. Display the PoE power usage. 4. Display topology information. 5. Display the alarm status. 6. Restart ports and devices. 7. Enable port lon |
|---|
| DHCP Snooping | disrupting the network and affecting normal network communication, and only allow DHCP packets from trusted ports to pass through. Disabled by default. |
|---|
| DDM (Digital Diagnostic | Support real-time monitoring of key parameters in optical modules, such as operating |
|---|
| Monitoring) | temperature, operating voltage, operating current, and Rx and Tx optical power. |
|---|
| PoE 標準 | IEEE 802.3af,IEEE 802.3at |
|---|
| PoE 供電腳位 | End-span: 1/2(-), 3/6(+) |
|---|
| PoE 埠 | PoE: Ports 1 to 16 |
|---|
| 單埠最大功率 | 30 W |
|---|
| PoE 功率預算 | 230 W CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020) UL (UL 60950-1); CB (IEC 60950-1:2005, AMD1:2009, AMD2:2013, IEC 62368-1: 2014 |
|---|
| Safety | (Second Edition); CE-LVD (EN 60950-1: 2006 + A11: 2009 +A1: 2010+A12: 2011+A2: 2013, EN 62368-1: 2014+A11: 2017) |
|---|
| Chemistry | CE-RoHS (2011/65/EU),WEEE (2012/19/EU),Reach (Regulation (EC) No.1907/2006) |
|---|