| Aruba 2920-24G Switch | Aruba 2920-24G-PoE+ Switch Aruba 2920-48G Switch (J9726A) (J9727A) (J9728A) 20 RJ-45 autosensing 10/100/1000 20 RJ-45 autosensing 10/100/1000 44 RJ-45 autosensing 10/100/1000 |
|---|
| ports (IEEE 802.3 Type 10BASE-T, | PoE+ ports (IEEE 802.3 Type ports (IEEE 802.3 Type 10BASE-T, |
|---|
| IEEE 802.3u Type 100BASE-TX, IEEE | 10BASE-T, IEEE 802.3u Type IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T); Duplex: 100BASE-TX, IEEE 802.3ab Type 802.3ab Type 1000BASE-T); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T, IEEE 802.3at PoE+); 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only Duplex: 10BASE-T/100BASE-TX: half 1000BASE-T: full only or full; 1000BASE-T: full only 4 RJ-45 dual-personality 4 RJ- |
|---|
| Type 10BASE-T, IEEE 802.3u Type | 10/100/1000 PoE+ ports (IEEE Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 802.3 Type 10BASE-T, IEEE 802.3u 100BASE-TX, IEEE 802.3ab Type 1000BASE-T) Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T) 1000BASE-T, IEEE 802.3at PoE+) 2 module slots 2 module slots 2 module slots 1 stacking module slot 1 stacking module slot 1 stacking module slot 1 dual-personality (RJ-45 or USB 1 dual-pe |
|---|
| micro-B) | micro-B) micro-B) 1 USB 1.1 1 USB 1.1 1 USB 1.1 1 RJ-45 out-of-band management port 1 RJ-45 out-of-band management port 1 RJ-45 out-of-band management port 1 power supply slot 1 power supply slot 1 power supply slot 1 minimum power supply required 1 minimum power supply required 1 minimum power supply required |
|---|
| includes: 1 x J9739A (HPE X331 | includes: 1 x J9738A (HPE X332 includes: 1 x J9739A (HPE X331 165W 100-240VAC to 12VDC Modu- 575W 100-240VAC to 54VDC Modu- 165W 100-240VAC to 12VDC Modu- |
|---|
| lar Power Supply) | lar Power Supply) lar Power Supply) |
|---|
| 尺寸 | 17.42 (w) x 13.23 (d) x 1.75 (h) in 17.42 (w) x 13.23 (d) x 1.73 (h) in 17.42 (w) x 13.23 (d) x 1.73 (h) in (44.25 x 33.6 x 4.45 cm) (44.25 x 33.6 x 4.4 cm) (44.25 x 33.6 x 4.4 cm) (1U height) (1U height) (1U height) |
|---|
| 重量 | 11.57 lb (5.25 kg) 12.04 lb (5.46 kg) 11.95 lb (5.42 kg) ARUBA 2920 SWITCH SERIES |
|---|
| Tri Core ARM1176 @ 625 MHz, | Tri Core ARM1176 @ 625 MHz, Tri Core ARM1176 @ 625 MHz, 512 MB SDRAM; Packet buffer size: 512 MB SDRAM; Packet buffer size: 512 MB SDRAM; Packet buffer size: 11.25 MB (6.75 MB dynamic egress 11.25 MB (6.5 MB dynamic egress + 11.25 MB (6.75 MB dynamic egress |
|---|
| + 4.5 MB ingress), 1 GB flash MB | 4.5 MB ingress), 1 GB flash + 4.5 MB ingress), 1 GB flash |
|---|
| Throughput | up to 95.2 Mpps up to 95.2 Mpps up to 130.9 Mpps |
|---|
| 交換容量 | 128 Gbps 128 Gbps 176 Gbps |
|---|
| Routing table size | 2048 entries (IPv4), 256 entries (IPv6) 2048 entries (IPv4), 256 entries (IPv6) 2048 entries (IPv4), 256 entries (IPv6) |
|---|
| MAC address table size | 16000 entries 16000 entries 16000 entries |
|---|
| 工作溫度 | 32°F to 131°F (0°C to 55°C) 32°F to 131°F (0°C to 55°C) 32°F to 131°F (0°C to 55°C) |
|---|
| Operating relative humidity | 15% to 95%, noncondensing 15% to 95%, noncondensing 15% to 95%, noncondensing |
|---|
| Nonoperating/Storage | -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C) -40°F to 158°F (-40°C to 70°C) |
|---|
| Altitude | up to 10,000 ft (3 km) up to 10,000 ft (3 km) up to 10,000 ft (3 km) |
|---|
| Acoustic | Power: 57 dB, Pressure: 41.4 dB Power: 61 dB, Pressure: 44.9 dB Power: 57 dB, Pressure: 41.8 dB ARUBA 2920 SWITCH SERIES |
|---|
| Frequency | 50/60 Hz 50/60 Hz 50/60 Hz Achieved Miercom Certified Green Award |
|---|
| Maximum heat dissipation | 198 BTU/hr (208.89 kJ/hr) 358 BTU/hr (377.69 kJ/hr) 239 BTU/hr (252.15 kJ/hr) |
|---|
| Voltage | 100 - 240 VAC, rated 100 - 240 VAC, rated 100 - 240 VAC, rated (depending on power supply chosen) (depending on power supply chosen) (depending on power supply chosen) |
|---|
| Maximum power rating | 58 W 475 W 70 W |
|---|
| Idle power | 26 W 42 W 27 W |
|---|
| PoE power | 370 W PoE+ |
|---|
| Notes | Idle power is the actual power Idle power is the actual power Idle power is the actual power |
|---|
| consumption of the device with no | consumption of the device with no consumption of the device with no |
|---|
| ports connected. | ports connected. ports connected. |
|---|
| Maximum power rating and | Maximum power rating and Maximum power rating and |
|---|
| maximum heat dissipation are the | maximum heat dissipation are the maximum heat dissipation are the |
|---|
| worst-case theoretical maximum | worst-case theoretical maximum worst-case theoretical maximum |
|---|
| numbers provided for planning | numbers provided for planning numbers provided for planning |
|---|
| the infrastructure with fully loaded | the infrastructure with fully loaded the infrastructure with fully loaded |
|---|
| PoE (if equipped), 100% traffic, all | PoE (if equipped), 100% traffic, all PoE (if equipped), 100% traffic, all |
|---|
| ports plugged in, and all modules | ports plugged in, and all modules ports plugged in, and all modules |
|---|
| populated. | populated. populated. PoE power is the power supplied by the internal power supply. It is dependent on the type and quan- tity of power supplies and may be supplemented with the use of an external power supply (EPS). 370 W of PoE+ power is available using the internal default power supply. |
|---|
| CE Labeled; EN 60825-1 Safety of | CE Labeled; EN 60825-1 Safety of CE Labeled; EN 60825-1 Safety of |
|---|
| Laser Products-Part 1; FCC Part 15, | Laser Products-Part 1; FCC Part 15, Laser Products-Part 1; FCC Part 15, |
|---|
| Subpart B; GOST; EU RoHS | Subpart B; GOST; EU RoHS Subpart B; GOST; EU RoHS |
|---|
| Compliant; EN 55022 Class A; EN | Compliant; EN 55022 Class A; EN Compliant; EN 55022 Class A; EN 55024: 1998; C-Tick; ICES-003, 55024: 1998; C-Tick; ICES-003, 55024: 1998; C-Tick; ICES-003, |
|---|
| Class A; VCCI Class A; IEC 60950- | Class A; VCCI Class A; IEC 60825- Class A; VCCI Class A; IEC 60825- 1, Second Edition ; IEC 60825-1; 1; IEC 60950-1, Second Edition; 1; IEC 60950-1, Second Edition; |
|---|
| EN62479:2010; CSA C22.2 No. | EN62479:2010; CSA C22.2 No. EN62479:2010; CSA C22.2 No. 60950-1-07 2nd Edition; EN 60950-1-07 2nd Edition; EN 60950-1-07 2nd Edition; EN 60950-1:2006+A11:2009+A1:2010 60950-1:2006+A11:2009+A1:2010 60950-1:2006+A11:2009+A1:2010 |
|---|
| +A12:2011; IEC 60950-1 (ed.2): am1 | +A12:2011; IEC 60950-1 (ed.2): am1 +A12:2011; IEC 60950-1 (ed.2): am1 |
|---|
| FCC part 15 Class A; VCCI Class A; | FCC part 15 Class A; VCCI Class A; FCC part 15 Class A; VCCI Class A; |
|---|
| EN 55022/CISPR 22 Class A | EN 55022/CISPR 22 Class A EN 55022/CISPR 22 Class A ARUBA 2920 SWITCH SERIES |
|---|
| EN | EN 55024, CISPR 24 EN 55024, CISPR 24 EN 55024, CISPR 24 |
|---|
| ESD | IEC 61000-4-2 IEC 61000-4-2 IEC 61000-4-2 |
|---|
| Radiated | IEC 61000-4-3 IEC 61000-4-3 IEC 61000-4-3 |
|---|
| EFT/Burst | IEC 61000-4-4 IEC 61000-4-4 IEC 61000-4-4) |
|---|
| Surge | IEC 61000-4-5 IEC 61000-4-5 IEC 61000-4-5 |
|---|
| Conducted | IEC 61000-4-6 IEC 61000-4-6 IEC 61000-4-6 |
|---|
| Power frequency | IEC 61000-4-8 IEC 61000-4-8 IEC 61000-4-8 |
|---|
| Voltage dips and | IEC 61000-4-11 IEC 61000-4-11 IEC 61000-4-11 |
|---|
| Harmonics | IEC 61000-3-2 IEC 61000-3-2 IEC 61000-3-2 |
|---|
| Flicker | IEC 61000-3-3 IEC 61000-3-3 IEC 61000-3-3 |
|---|
| Aruba Central; Aruba AirWave | Aruba Central; Aruba AirWave Aruba Central; Aruba AirWave |
|---|
| Network Management; IMC – | Network Management; IMC – Network Management; IMC – |
|---|
| Intelligent Management Center; | Intelligent Management Center; Intelligent Management Center; |
|---|
| Command-line interface; Web | Command-line interface; Web Command-line interface; Web |
|---|
| browser; Configuration menu; | browser; Configuration menu; browser; Configuration menu; |
|---|
| Out-of-band management (RJ-45 | Out-of-band management (RJ-45 Out-of-band management (RJ-45 |
|---|
| Ethernet); SNMP manager; Telnet; | Ethernet); SNMP manager; Telnet; Ethernet); SNMP manager; Telnet; |
|---|
| RMON1; FTP; In-line and out-of- | RMON1; FTP; In-line and out-of- RMON1; FTP; In-line and out-of- |
|---|
| band; Out-of-band management | band; Out-of-band management band; Out-of-band management (serial RS-232c or micro usb) (serial RS-232c or micro usb) (serial RS-232c or micro usb) |
|---|
| Refer to the Hewlett Packard | Refer to the Hewlett Packard Refer to the Hewlett Packard |
|---|
| Enterprise website at | Enterprise website at Enterprise website at |
|---|
| www.hpe.com/networking/services | www.hpe.com/networking/services www.hpe.com/networking/services |
|---|
| for details on the service-level | for details on the service-level for details on the service-level |
|---|
| descriptions and product numbers. | descriptions and product numbers. descriptions and product numbers. |
|---|
| For details about services and | For details about services and For details about services and |
|---|
| response times in your area, please | response times in your area, please response times in your area, please |
|---|
| contact your local Hewlett Packard | contact your local Hewlett Packard contact your local Hewlett Packard |
|---|
| Enterprise sales office. | Enterprise sales office. Enterprise sales office. ARUBA 2920 SWITCH SERIES |
|---|
| Aruba 2920-48G-PoE+ Switch (J9729A) | Aruba 2920-48G-PoE+ 740W Switch (J9836A) 44 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 44 RJ-45 autosensing 10/100/1000 PoE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+); Duplex: 802.3ab Type 1000BASE-T, IEEE 802.3at PoE+); Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE |
|---|
| ingress), 1 GB flash | ingress), 1 GB flash |
|---|
| device with no ports connected. | vice with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case the- Maximum power rating and maximum heat dissipation oretical maximum numbers provided for planning the are the worst-case theoretical maximum numbers pro- infrastructure with fully loaded PoE (if equipped), 100% vided for planning the infrastructure with fully loaded traffic, all ports plugged in, |
|---|
| all modules populated. | PoE power is the power supplied by the internal power supply. It is dependent on the type and quantity of PoE power is the power supplied by the internal power power supplies and may be supplemented with the supply. It is dependent on the type and quantity of use of an external power supply (EPS). power supplies and may be supplemented with the |
|---|
| use of an external power supply (EPS). | Idle power is the actual power consumption of the device with no ports connected. 740 W of PoE+ power 370 W of PoE+ power is available using the internal is available using the internal default power supply. default power supply. CE Labeled; EN 60825-1 Safety of Laser Products-Part CE Labeled; EN 60825-1 Safety of Laser Products-Part 1; FCC Part 15, Subpart B; GOST; EU RoHS Compliant; 1; FCC Part |
|---|
| Class A | Class A |
|---|
| sales office. | sales office. |
|---|
| STANDARDS AND PROTOCOLS | General protocols |
|---|
| Denial of service protection | • IEEE 802.1D MAC Bridges |
|---|
| • CPU DoS Protection | • IEEE 802.1p Priority • IEEE 802.1Q VLANs • IEEE 802.1s Multiple Spanning Trees • RFC 1155 Structure and Mgmt Information (SMIv1) • IEEE 802.1v VLAN classification by Protocol and Port • RFC 1157 SNMPv1/v2c • IEEE 802.1w Rapid Reconfiguration of Spanning Tree • RFC 1591 DNS (client) • IEEE 802.3ab 1000BASE-T • RFC 1901 (Community based SNMPv2) • IEEE 802.3ad Link Aggregation Control Protocol (LAC |
|---|
| • RFC 2236 IGMP Snooping | • RFC 2925 Definitions of Managed Objects for Remote |
|---|
| • RFC 2453 RIPv2 | Ping, Traceroute, and Lookup Operations (Ping only) • RFC 2865 Remote Authentication Dial In User • RFC 2925 Remote Operations MIB (Ping only) |
|---|
| Service (RADIUS) | • RFC 3019 MLDv1 MIB |
|---|
| • RFC 2866 RADIUS Accounting | • RFC 3315 DHCPv6 (client and relay) • RFC 3046 DHCP Relay Agent Information Option • RFC 3484 Default Address Selection for IPv6 • RFC 3411 An Architecture for Describing Simple Network • RFC 3513 IPv6 Addressing Architecture Management Protocol (SNMP) Management Frameworks • RFC 3596 DNS Extension for IPv6 • RFC 3412 Message Processing and Dispatching for the • RFC 3810 MLDv2 for IPv6 |
|---|
| Simple Network Management Protocol (SNMP) | • RFC 4022 MIB for TCP • RFC 3413 Simple Network Management Protocol (SNMP) • RFC 4113 MIB for UDP |
|---|
| Applications | • RFC 4251 SSHv6 Architecture • RFC 3414 User-based Security Model (USM) for version 3 • RFC 4252 SSHv6 Authentication of the Simple Network Management Protocol (SNMPv3) • RFC 4253 SSHv6 Transport Layer • RFC 3415 View-based Access Control Model (VACM) for • RFC 4254 SSHv6 Connection the Simple Network Management Protocol (SNMP) • RFC 4291 IP Version 6 Addressing Architecture |
|---|
| • RFC 3416 Protocol Operations for SNMP | • RFC 4293 MIB for IP • RFC 3417 Transport Mappings for the Simple Network • RFC 4419 Key Exchange for SSH |
|---|
| Management Protocol (SNMP) | • RFC 4443 ICMPv6 • RFC 3418 Management Information Base (MIB) for the • RFC 4541 IGMP & MLD Snooping Switch |
|---|
| • RFC 3576 Ext to RADIUS (CoA only) | • RFC 4862 IPv6 Stateless Address Auto-configuration • RFC 4541 Considerations for Internet Group Management • RFC 5095 Deprecation of Type 0 Routing Headers in IPv6 Protocol (IGMP) and Multicast Listener Discovery (MLD) • RFC 6620 FCFS SAVI |
|---|
| Snooping Switches | • draft-ietf-savi-mix • RFC 4675 RADIUS VLAN & Priority MIBs • RFC 4861 Neighbor Discovery for IP version 6 (IPv6) • IEEE 802.1ap (MSTP and STP MIB’s only) • RFC 4862 IPv6 Stateless Address Autoconfiguration • RFC 1155 Structure & ID of Mgmt Info for TCP/IP Internets • RFC 5905 Network Time Protocol Version 4: Protocol • RFC 1156 (TCP/IP MIB) • UDLD (Uni-directional Link Detection) • RFC 1157 A Si |
|---|
| IP multicast | • RFC 1213 MIB II |
|---|
| • RFC 1112 IGMP | • RFC 1493 Bridge MIB |
|---|
| • RFC 2236 IGMPv2 | • RFC 1724 RIPv2 MIB • RFC 2710 Multicast Listener Discovery (MLD) for IPv6 • RFC 2021 RMONv2 MIB |
|---|
| • RFC 3376 IGMPv3 | • RFC 2578 Structure of Management Information • RFC 4541 Considerations for Internet Group Management Version 2 (SMIv2) Protocol (IGMP) and Multicast Listener Discovery (MLD) • RFC 2579 Textual Conventions for SMIv2 |
|---|
| • RFC 2618 RADIUS Client MIB | RFC 3414 SNMP-User • RFC 1981 IPv6 Path MTU Discovery based-SM MIB • RFC 2080 RIPng for IPv6 • RFC 2620 RADIUS Accounting MIB • RFC 2081 RIPng Protocol Applicability Statement • RFC 2665 Ethernet-Like-MIB • RFC 2082 RIP-2 MD5 • RFC 2668 802.3 MAU MIB • RFC 2460 IPv6 Specification • RFC 2674 802.1p and IEEE 802.1Q Bridge MIB • RFC 2464 Transmission of IPv6 over Ethernet Networks • RFC 2737 Entity M |
|---|
| • RFC 2819 RMON MIB | Security |
|---|
| • RFC 2863 The Interfaces Group MIB | • IEEE 802.1X Port Based Network Access Control |
|---|
| • RFC 2925 Ping MIB | • RFC 1321 The MD5 Message-Digest Algorithm |
|---|
| • RFC 2932 IP (Multicast Routing MIB) | • RFC 1334 PPP Authentication Protocols (PAP) |
|---|
| • RFC 2933 IGMP MIB | • RFC 1492 An Access Control Protocol, Sometimes |
|---|
| • RFC 3414 SNMP-User based-SM MIB | Called TACACS |
|---|
| • RFC 3415 SNMP-View based-ACM MIB | • RFC 1492 TACACS+ • RFC 3417 Simple Network Management Protocol (SNMP) • RFC 1994 PPP Challenge Handshake Authentication |
|---|
| over IEEE 802 Networks | Protocol (CHAP) |
|---|
| • RFC 3418 MIB for SNMPv3 | • RFC 2082 RIP-2 MD5 Authentication • RFC 4836 Managed Objects for 802.3 Medium Attachment • RFC 2104 Keyed-Hashing for Message Authentication |
|---|
| Units (MAU | • RFC 2138 RADIUS Authentication • RFC 2139 RADIUS Accounting • RFC 2246 Transport Layer Security (TLS) • IEEE 802.1AB Link Layer Discovery Protocol (LLDP) • RFC 2548 Microsoft Vendor-specific RADIUS Attributes • RFC 1155 Structure of Management Information • RFC 2618 RADIUS Authentication Client MIB • RFC 1157 SNMPv1 • RFC 2620 RADIUS Accounting Client MIB • RFC 2021 Remote Network Monitoring Man |
|---|
| QoS/CoS | • Port Security |
|---|
| • IEEE 802.1p (CoS) | • Secure Sockets Layer (SSL) • RFC 2474 DiffServ Precedence, including 8 queues/port • SSHv2 Secure Shell • RFC 2597 DiffServ Assured Forwarding (AF) • Web Authentication • RFC 2598 DiffServ Expedited Forwarding (EF) • Ingress Rate Limiting ARUBA 2920 SWITCH SERIES |
|---|
| ARUBA 2920 SWITCH SERIES ACCESSORIES | Cables |
|---|
| Modules | • HPE 0.5 m Multimode OM3 LC/LC Optical Cable (AJ833A) • HPE 2920 2-Port 10GbE SFP+ Module (J9731A) • HPE 1 m Multimode OM3 LC/LC Optical Cable (AJ834A) • HPE 2920 2-port 10GBASE-T Module (J9732A) • HPE 2 m Multimode OM3 LC/LC Optical Cable (AJ835A) • HPE 2920 2-Port Stacking Module (J9733A) • HPE 5 m Multimode OM3 LC/LC Optical Cable (AJ836A) • HPE 2920 2-port 10GbE SFP+ Module/S-Buy (J9731AS) • |
|---|
| Cable (J9301A) | Power Supply • HPE X244 10G XFP to SFP+ 3m Direct Attach Copper • HPE 640 Redundant/External Power Supply Shelf (J9805A) |
|---|
| Cable (J9302A) | Mounting Kit • HPE X132 10G SFP+ LC SR Transceiver/S-Buy (J9150AS) • HPE X410 1U Universal 4-post Rack Mounting Kit (J9583A) • HPE X132 10G SFP+ LC LR Transceiver/S-Buy (J9151AS) • HPE X132 10G SFP+ LC LRM Transceiver/S-Buy (J9152AS) HP 2920-48G-PoE+ 740W Switch (J9836A) • HPE X242 40G QSFP+ to QSFP+ 1m Direct Attach Copper • HPE X332 575W 100-240VAC to 54VDC Modular Power |
|---|
| Cable (JH234A) | Supply (J9738A) • HPE X242 40G QSFP+ to QSFP+ 3m DAC Cable (JH235A) • HPE X332 1050W 110-240VAC to 54VDC Power Supply • HPE X242 40G QSFP+ to QSFP+ 5m DAC Cable (JH236A) (J9737A) 3333 SCOTT BLVD | SANTA CLARA, CA 95054 1.844.473.2782 | T: 1.408.227.4500 | FAX: 1.408.227.4550 | INFO@ARUBANETWORKS.COM |
|---|
| www.arubanetworks.com | DS_2920SwitchSeries_010518 |
|---|