| Camera | CISPR 35, CISPR 32 Class A, ECE R10 rev.06, EN 55035, EN 55032 Class A, EN 61000-6-1, EN 61000-6-2 |
|---|
| 影像感測器 | Australia/New Zealand: RCM AS/NZS CISPR 32 Class A Uncooled VOx microbolometer 160x120 pixels Canada: ICES(A)/NMB(A) |
|---|
| Pixel size 12 µm | Japan: VCCI Class A |
|---|
| Spectral range: 8–14 µm | Korea: KS C 9835, KS C 9832 Class A USA: FCC Part 15 Subpart B Class A Railway: IEC 62236-4 Athermalized |
|---|
| Horizontal field of view: 95° or 57° | Safety Minimum focus distance: 0.12 m (0.4 ft) with 95°HFoV CAN/CSA C22.2 No. 62368-1 ed. 3, |
|---|
| or 0.3 m (1.0 ft) with 57° HFoV | RCM AS/NZS 62368.1:2022, IEC/EN/UL 62368-1 ed. 3, UL recognized component, UN ECE R118 Sensitivity |
|---|
| NETD < 50 mK @25C, F1.1 | Environment IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-27, IEC 60068-2-64, IEC 60068-2-78, |
|---|
| Thermometry | IEC 60721-3-5 Class 5M3 (Vibration, Shock), IEC/EN 60529 IP66/IP67, ISO 20653 IP6K9K Object temperature range |
|---|
| -10 °C to 450 °C (14 °F to 842 °F) | Cybersecurity |
|---|
| Temperature accuracy | Documentation 10 °C to 140 °C (50 °F to 284 °F): ±5 °C (±9 °F) AXIS OS Hardening Guide |
|---|
| accuracy1 | Axis Vulnerability Management Policy 140 °C to 450 °C (284 °F to 842 °F): ±10% accuracy1 Axis Security Development Model AXIS OS Software Bill of Material (SBOM) To download documents, go to axis.com/support/ |
|---|
| Detection range | cybersecurity/resources We recommend the size of a monitored object to cover To read more about Axis cybersecurity support, go to at least 10x10 pixels in 160x120. axis.com/cybersecurity |
|---|
| General | General Spot temperature meter Up to 4 polygonal temperature detection areas Casing IP662-, IP672-, and IP6K9K2-rated |
|---|
| Approvals | Aluminum casing Color: black NCS S 9000-N Product markings |
|---|
| UL/cUL, CE, FCC, KC, VCCI, RCM | Power Max 1.6 W Supply chain |
|---|
| TAA compliant | Connectors SMA connector Operating conditions Temperature monitoring: -10 °C to 60 °C (14 °F to 140 °F) Humidity: 10–100% RH (condensing) Substance control |
|---|
| 尺寸 | PVC free, BFR/CFR free in accordance with JEDEC/ECA |
|---|
| drawing in this datasheet. | RoHS in accordance with EU RoHS Directive 2011/65/ EU and 2015/863, and standard EN IEC 63000:2018 REACH in accordance with (EC) No 1907/2006. For SCIP |
|---|
| 重量 | UUID, see echa.europa.eu Materials |
|---|
| Box content | Renewable carbon-based plastic content: 30% (carbon |
|---|
| Sensor, installation guide | capture based) Screened for conflict minerals in accordance with OECD guidelines To read more about sustainability at Axis, go to axis. com/about-axis/sustainability Environmental responsibility axis.com/environmental-responsibility Axis Communications is a signatory of the UN Global Compact, read more at unglobalcompact.org AXIS F2180-TE (95° HFoV) |
|---|
| Definition | Distance |
|---|
| Detect | 1.5 pixels Human: 50 m (160 ft) Vehicle: 140 m (459 ft) |
|---|
| Recognize | 6 pixels Human: 12 m (39 ft) Vehicle: 35 m (110 ft) |
|---|
| Identify | 12 pixels Human: 6 m (20 ft) Vehicle: 19 m (62 ft) AXIS F2180-TE (57° HFoV) |
|---|
| www.axis.com | T10225921/EN/M2.2/202604 © 2026 Axis Communications AB. AXIS COMMUNICATIONS, AXIS, ARTPEC and VAPIX are registered trademarks of Axis AB in various jurisdictions. All other trademarks are the property of their respective owners. We reserve the right to introduce modifications without notice. |
|---|