| 機身 | Metal material |
|---|
| 淨重 | 0.6 kg (1.3 lb) |
|---|
| 毛重 | 1.2 kg (2.6 lb) |
|---|
| 尺寸 | 197.00 mm × 114.20 mm × 42.20 mm (7.70'' × 4.40'' × 1.60'') |
|---|
| 工作溫度 | -30 °C to 65 °C (-22 °F to 149 °F) |
|---|
| 儲存溫度 | -40 °C to 85 °C (-40 °F to 185 °F) |
|---|
| 工作濕度 | 5% to 95% (no condensation) |
|---|
| 相對濕度 | 5% to 95% (no condensation) |
|---|
| 供電 | 48 V DC, 2.5 A |
|---|
| 安裝方式 | Desk-Mounted,Rail |
|---|
| 最大功耗 | 120 W |
|---|
| 閒置功耗 | 10 W |
|---|
| 防雷 | 6 kV |
|---|
| Ports | 8 × 10/100 Mbps PoE port,1 × Gigabit RJ45 port,1 × Gigabit fiber optical port |
|---|
| MAC 位址表 | 16 K Whole-Device Performance: 9.2 Gbps Port Performance: 5.6 Gbps Whole-Device Performance: 6.84 Mpps Port Performance: 4.17 Mpps |
|---|
| 內部緩存 | 4 Mbits |
|---|
| PoE 標準 | IEEE 802.3af,IEEE 802.3at |
|---|
| PoE 供電腳位 | 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-) |
|---|
| PoE 埠 | PoE: Ports 1 to 8 |
|---|
| 單埠最大功率 | 30 W |
|---|
| PoE 功率預算 | 110 W Ports 1 to 8: up to 300 m. Long range performance may vary depend on camera model or cable condition. Ports 1 to 8: port isolation mode to improve network security |
|---|
| Port Isolation | Ports in an isolation group cannot communicate with each other, but they can communicate with ports outside the isolation group. |
|---|
| PoE Watchdog | Ports 1 to 8: auto detect and restart the cameras that do not respond. QoS is used to allocate bandwidth to different services so as to provide end-to-end service quality assurance. Support port-based priority configuration. Support SP, WRR priority schedule mode. VLAN is used for network scale planning and network health improvement. Support 802.1Q. |
|---|
| VLAN | Configurable VLAN ID from 1-4094. Support Trunk, Access port mode. Support Max. 4094 VLAN. load balancing, bandwidth expansion, and port protection. Link Aggregation Support static link aggregation. Support 1 aggregation group(s). Support one-click activation and remote management via Hik-Partner Pro. Functions supported: 1. Display the port rate. 2. Display the port bandwidth utilization rate. 3. |
|---|
| DHCP Snooping | disrupting the network and affecting normal network communication, and only allow DHCP packets from trusted ports to pass through. Disabled by default. Port rate-limiting is used for port bandwidth adjustment to prevent network Port Rate-Limiting congestion. CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: |
|---|
| EMC | 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020),IC (ICES-003: Issue 7:2020) CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition)), CE-LVD (EN 62368- 1: 2014+A11: 2017) |
|---|
| Chemistry | CE-RoHS (2011/65/EU),WEEE (2012/19/EU),Reach (Regulation (EC) No.1907/2006) |
|---|