| • Detection Method | • Pet/Animal Immunity • Low Temperature Detection |
|---|
| – Dual Element Passive Infrared | – (5800PIR and 5800PIR-RES – Fault = < 45° F (7° C) |
|---|
| only)—up to 80 lbs. (36Kg) | for > 10 to 30 minutes – Restore = > 48° F (9° C) |
|---|
| - 5800PIR/-RES = 35' x 40' | • Mounting Height for > 10 to 30 minutes (11m x 12m) – 7' to 9' (2.3m to 2.7m) |
|---|
| - 5800PIR-COM = 60' x 80' | • Dimensions • Tamper Switch (18m x 26m); 100' x 20' – W= 8.7cm [2.4"] – Front and cover/back (30m x 6m) – H= 6.1cm [3.4"] |
|---|
| • Sensitivity | – D= 3.9cm [1.5"] – Remotely selectable— |
|---|
| – Battery (included) – 1 x 3V, | • Weight 5800PIR–high, pulse count 1 (no |
|---|
| CR123A/DL 123A /466 | – 81G, [2.9oz] Packaged pet immunity) or low, pulse count 2 product = 112G, [4oz] |
|---|
| • Battery Life* | (up to 80 lbs. of Pet Immunity) |
|---|
| - Up to seven years; 38% longer | – 5800PIR-COM–high, pulse count 1 • Includes |
|---|
| battery life than 5890PI (in a typical | or low, pulse count 2 – Mounting hardware (5800PIR and |
|---|
| installation with an average of | 5800PIR-COM only) • Self Test (5800PIR and 80 motion events per day) – Lens Masking (5800PIR and 5800PIR-COM) 5800PIR-COM only) |
|---|
| • RF Frequency | – Internally checks the PIR circuit – Look Down Lens (5800PIR and |
|---|
| – 345 MHz | every 10 minutes and disables 5800PIR-COM only) the RF supervision signal if six |
|---|
| • Operating Temperature | – 3V Lithium Battery consecutive self tests fail |
|---|
| – (for indoor use environment) | – 100' x 20' Curtain Lens 14° F to 131° F (-10° C to 55° C) • PIR Fields of View (5800PIR-COM only) |
|---|
| -4° F to 131° F (-20° C to 55° C) | (44 long range, 36 intermediate, – FCC part 15, Class B verified |
|---|
| for the 5800PIR-COM | 18 lower, four look-down) – IC, ICES-003, Class B verified – 60' x 80' lens = 66 zones (44 long |
|---|
| • Relative Humidity, | – C-Tick range, 12 intermediate, six lower, |
|---|
| non-condensing | – CE four look-down) |
|---|
| – 95% max | – SIA-PIR-01 Passive Infrared – 100' x 20' lens = 16 zones detector standard features for false |
|---|
| • Detectable Walk Rate | (four long range, four intermediate, alarm immunity |
|---|
| – 0.7 – 7ft/Sec. (0.2 – 2.0m/Sec.) | four lower, four look-down) – cETLus |
|---|
| • Temperature Compensation | – UL – Advanced Dual Slope |
|---|
| IS2500-HSLK | 35' High Security Lens Kit (10 pack) |
|---|
| IS2500-PALK | Pet Alley Lens Kit (10 pack) |
|---|
| SMB10 | SMB10T SMB10C L/5800PIRD/D |
|---|
| www.honeywell.com | © 2011 Honeywell International Inc. |
|---|