HONEYWELL 95C-10879 安裝、保養、維修

95C-10879

裝ALARM | 裝防盜 | 裝警鐘 — 硬件連工程一站式

產品簡介

honeywell 95C-10879 為Direct Coupled Valve Actuator,HKEZIT 提供原廠行貨連保養、上門安裝、調試及使用教學一站式服務。詳細規格以下方原廠 Datasheet 欄位為準,歡迎聯絡我們查詢 95C-10879 香港價格連安裝報價。

  • IMPORTANT::Accessories/Parts:
  • those conditions are changed.:Stroke--19mm (3/4") or less Stroke timing-- Approx. 63 secon
  • -40°C to +65°C (-40°F to 150°F):Performance Specifications:
  • 相對濕度:Minimum Signal Input Duration: 200 milli-second conditions)
  • Acoustic Noise::whichever occurs first.
HKEZIT 提供原廠行貨保養。硬件連專業安裝、設定及使用教學一站式報價,無需自行研究安裝與設定。我們同時承接裝ALARM、裝防盜、裝警鐘工程,硬件與工程同一團隊負責。
查詢價格連安裝

詳細規格

IMPORTANT:Accessories/Parts:
those conditions are changed.Stroke--19mm (3/4") or less Stroke timing-- Approx. 63 seconds for 3/4" stroke Closing Force-- 710N (160 lbs.) Nominal* *Rating applies to both directions.
-40°C to +65°C (-40°F to 150°F)Performance Specifications:
相對濕度Minimum Signal Input Duration: 200 milli-second conditions) 50,000 full stroke cycles plus 1,000,000 repositions at 10% stem travel or 10 years,
Acoustic Noise:whichever occurs first.
!CAUTION Minimum required control signal input duration is 200 milli-second. Short and rapid cycling/repositioning will result in possible device lock-up or reduced service life. 1. Model number. 2. Valve body type and model number. 3. Accessories, if desired. 1. Your local Honeywell Home and Building Control Sales office (Check white pages of your phone directory). 2. Home and Building Control Cus
In U.S.A. --Honeywell Inc. 1985 Douglas Drive North, Minneapolis, Minnesota 55422-4386 (612) 951-1000 Mounting:
安裝1. Ensure that the valve body is installed correctly, that is, the arrow points in the direction of the flow. 2. Although the actuator can be mounted in any position, it is preferable that the ML6984 is mounted above the valve body. This will minimize the risk of damage to the ML6984 in the event of condensation or a valve gland leak. 3. Remove the stem button (Fig. 3) from the valve stem. Save th
FIG.2 -- MINIMUM MOUNTING CLEARANCE.threads showing), by turning the valve actuator in a clockwise direction, as viewed from above (depending on the valve models, use a pin or wrench to keep valve stem from turning). Note that the valve
occur.4. Orient the conduit hole to the most desirable direction, then tighten the LOCKNUTS on the U-bolt.
FIG.3 -- PREPARATION FOR VALVE ASSEMBLY.FIG. 4 -- ASSEMBLY OF ML6984A TO VALVE. the two screws located on the top (Note: These screws are captive. Rotate three complete revolutions to remove or Allen Wrench cover ). Drop either Slot Headed or Allen Hex type of set screw (both are included in the plastic bag ) into the top of the shaft, slotted/ Hexed side up. Or use the set screw from the valve stem button. 5 mm (3/16") Slotted screwdri
FIG. 5 -- U-BOLT ASSEMBLY.FIG. 6. -- LOCKING ML6984A DRIVE SHAFT TO VALVE STEM
Typical Electronic ControllerML6984 3
L1H 1 W T6 24 Vac 3-wire control systems
CT5 3 B 1 Typical Electro-mechanical
ControllerML6984 3
L2R W
BT5
Typical SPDT Controller3 ML6984
WT6 24 Vac
T6+ 28 Vdc
the last position.same electrical circuit. For multiple actuators controlled by a common controller in parallel, these actuators must be To replace ML6874: 1. The new ML6984 is a direct replacement for the old ML6874 in single actuator hook-up.
! CAUTION:2. For parallel multiple old ML6874 actuators applications, 1. Disconnect power supply before beginning an isolation relay must be used (isolation relay contacts installation to prevent electrical shock and should be placed in the new ML6984 actuator signal input
equipment damage."W" and "B" circuit). 2. All wiring must comply with applicable local electrical codes, ordinances and regulations. Checkout: 3. Make certain that the voltage and frequency of 1. Make sure the valve stem is completely screwed into the the power supply correspond to the rating of actuator drive shaft with no threads showing.
the device.2. Make sure the valve stem is locked in place with the set 4. DO NOT electrically operate the ML6984 screw.
before assembly to the valve because3. With 24 Vac or 28Vdc power supply connected to T5 &
damage not apparent to the installer mayT6.
Home and BuildingHome and Building modification to, the literature. You will defend and indemnify
ControlControl Honeywell, its affiliates and subsidiaries, from and against any
Honeywell Limited/LimiteeHoneywell Inc. liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you. 155 Gordon Baker Road 1985 Douglas Drive North
North York , ONGolden Valley, MN 55422 Canada M2H 3N7 www.honeywell.com

* 規格以原廠最新 Datasheet 為準。

下載完整PDF規格書

防盜報警安裝工程服務

HKEZIT 專營裝ALARM、裝防盜、裝警鐘工程,95C-10879 由我們供貨、安裝、調試到使用教學一站式完成。無論裝ALARM、裝防盜或裝警鐘,均由自家工程團隊上門施工,品質有保證。

裝ALARM裝防盜裝警鐘

防盜報警適合邊類專業客戶

95C-10879 honeywell Direct Coupled Valve Actuator亦適合以下專業服務機構使用,保安同合規要求同一般商鋪唔一樣,歡迎查詢度身方案。

信託公司/家族辦公室

私人會議室同資料保存區極高保密規格,保障客戶身份同資產私隱。

WhatsApp 查詢 →

眼科診所

精密激光同檢查儀器防盜,診症室私隱合規佈點,配合預約系統減少候診糾紛。

WhatsApp 查詢 →

心臟科診所

心電圖同貴重心臟監測儀器防盜,診症室私隱合規佈點,配合預約系統。

WhatsApp 查詢 →

牙科診所

診症室私隱合規佈點、X光及貴重牙科儀器防盜,配合預約系統減少候診糾紛。

WhatsApp 查詢 →

會計師行

審計旺季外勤同事考勤管理、財務資料室保安,同會計師行嘅合規要求相符。

WhatsApp 查詢 →

知識產權/專利代理

未公開專利同商業機密文件保安要求極高,防止資料外洩爭議。

WhatsApp 查詢 →

常見問題

95C-10879 香港哪裡有代理?

HKEZIT 提供原廠行貨連保養,95C-10879 原廠行貨連保養,提供上門評估、安裝、防區設定及使用教學一站式服務,全港 32 區均有服務。

此設備適合什麼場景?

詳細規格請參閱上方規格表;我們會按現場環境(商舖、辦公室、倉庫、住宅)設計防區及感應器布局,並提供整體方案報價。

觸發警報後如何通知?

可按需求配置本地警號、手機 App 推送或短訊通知;亦可與 CCTV 聯動,觸發時自動錄影存證。

95C-10879 定 VM-SERIES-QUADRATURE-SENSOR-IC 邊個好?

兩者屬同系列產品,實際應該邊個型號更適合,需視乎現場環境同需求而定。歡迎直接聯絡我們免費現場評估,由工程師建議最合適方案。

95C-10879 保養、維修邊度做?

HKEZIT 提供 95C-10879 原廠行貨連保養,安裝後如有故障可直接聯絡我們安排上門維修,毋須自行聯絡原廠。詳情請參閱防盜報警安裝工程頁面或聯絡我們查詢保養範圍。

香港安裝服務地區

HKEZIT 於全港各區提供 95C-10879 honeywell Direct Coupled Valve Actuator供貨連專業安裝服務(裝ALARM、裝防盜、裝警鐘),熱門地區包括:元朗防盜報警系統安裝北角防盜報警系統安裝土瓜灣防盜報警系統安裝大圍防盜報警系統安裝大埔防盜報警系統安裝大角咀防盜報警系統安裝將軍澳防盜報警系統安裝尖沙咀防盜報警系統安裝。港島、九龍、新界全港 32 區均有上門安裝,歡迎聯絡我們查詢 95C-10879 香港價格連安裝報價。

防盜報警適用場景

95C-10879 honeywell Direct Coupled Valve Actuator適合多種場景使用,以下為部分常見安裝場景,歡迎查詢是否適合您的現場環境。

查看更多防盜報警適用場景,請參閱 防盜報警安裝工程

相關產品

如需整套防盜報警方案,請參閱 防盜報警安裝工程

查詢 95C-10879 連安裝價格

免費上門評估,即日報價,原廠行貨保養

立即查詢