| Mounting | M5 GRADE 8.8 BOLT (X2), recommended mounting torque is 6 Nm ±1 Nm |
|---|
| 重量 | 40 g max. |
|---|
| 尺寸 | 78,88 mm × 64,13 mm × 17,00 mm |
|---|
| Housing material | VALOX DR48 17 % GF |
|---|
| Flammability | UL 94 V-0 |
|---|
| 防護等級 | IP3X BES Series Datasheet | automation.honeywell.com/hss | 3 64,13 50,00 |
|---|
| Figure 1. Product Dimensions | 40,24 17,00 4x 43.6° TABLE 2. PIN OUT |
|---|
| Pin | Description 1 Power input 2 Ground 3 CAN H 61,25 4 CAN L 78,88 , NOTE: BES is designed for single use only. It must be replaced after exposure to a thermal event. |
|---|
| Pin 2 | Pin 3 |
|---|
| Pin 1 | Pin 4 2x 7,925 21,90 |
|---|
| BES - 1 | 3 1 -1 1 1 - 001 |
|---|
| BES – Electrolyte Vapor | RESERVED FOR FUTURE USE |
|---|
| ELECTRICAL POWER | CAN ADDRESS 3 – 0xE6 4 – 0xE7 5 – 0xE8 |
|---|
| SEALING | 6 – 0xE9 OUTPUT 1 – CAN 2.0B |
|---|
| CONNECTOR | (Baud Rate 250 kbps) (Baud Rate 500 kbps) REDUNDANCY 1 – None BES Series Datasheet | automation.honeywell.com/hss | 4 29-BIT ID DATA (8 BYTES) Scalar |
|---|
| Low | High |
|---|
| Field | P EDP DP PF PS SA State Deg C Byte Byte Not Used |
|---|
| # Bits | 3 1 1 8 8 8 8 8 8 8 8 8 8 8 0x08 0xFF 0x01 0xE4 0x03 0x17 0x1C 0x00 0xFF 0xFF 0xFF 0xFF |
|---|
| Message | Description Temperature (C) = (int8_t) * Deg C |
|---|
| EDP/DP=0 | J1939 standard data page Value=(int16_t) Scalar/100 |
|---|
| PF = 0xEF | Peer-to-peer message Typical warm up -2.00 |
|---|
| Destination address | Clean Air 0.00 (address of the controller) |
|---|
| Thermal runaway alarm | >1.00 |
|---|
| SA = 0xE4 | Source address (address of BES sensor) |
|---|
| High level of electrolytes | >4.00 |
|---|
| STATE: REPRESENTS THE STATE OF SENSOR | Example |
|---|
| Error | 0x01 Scalar (0x001C = 28) |
|---|
| Warmup | 0x02 |
|---|
| Normal | 0x03 |
|---|
| 警報 | 0x04 |
|---|
| SENSOR OPERATING MODE | PDU 0xEF00/61184 | ID |
|---|
| Frame | ID for operating mode is 29-BIT ID DATA (2 BYTES) ID |
|---|
| Format | 0x01 |
|---|
| CAN | ECO Mode 0x02 0x19 0xEF 0xE4 0xF6 0x01 0x00 |
|---|
| Severity | Protect=0, Warning=1, Stop=2, Malfunction=3 BES Sensor CRC Error (Light=1, Flash = 3, Severity = 1, |
|---|
| Light | 0=Off, 1=On, 2=Error, 3=Any DTC=0x7E271, FMI = 0x1F, occurrence = 3) |
|---|
| Flash | 0=Slow, 1=Fast, 3=No Flash Example |
|---|
| DTC | 0x7E000 - 0x7FFFF refer to fault codes |
|---|
| ID | 18FECAE4x most severe=0, 0x1F = not available: ref |
|---|
| FMI | Data 04 0C 71 E2 FF 03 FF FF J1939-73 |
|---|
| Occurrence | 1-127 BES Series Datasheet | automation.honeywell.com/hss | 5 DM3 (J1939-73 Standard) | PDU 0xFECC / 65228 Frame 29-BIT ID DATA (8 BYTES) Format |
|---|
| BES SERIES | ISO 7637-2 |
|---|
| Test | Standard Procedure |
|---|
| CISPR25 | Section 6.2, Class 3 |
|---|
| CISPR 25 Radiated Emissions | CISPR25 Section 6.4, Class 3 |
|---|
| Transient Conducted Emission | ISO 7637-2 Section 6.2 |
|---|
| Bulk Current Injection (BCI) Test | ISO 11452-4 Frequency range: 1 MHz to 400 MHz, Test Level 200 mA Frequency range: 200 MHz to 1 GHz, Test Level 150 V/m |
|---|
| RF Radiated Immunity - ALSE | ISO 11452-2 1 GHz to 6 Ghz, Test Level 100 V/m Frequency range: 10 kHz to 400 MHz, |
|---|
| RF Radiated Immunity - Stripline | ISO 11452-5 Test Level: 200 V/m Unpowered direct contact discharge: ±6 kV Unpowered air discharge: ±15 kV |
|---|
| Electrostatic Discharge | ISO 10605 Powered-up direct contact discharge: ±8 kV Powered-up air discharge: ±15 kV Network: 330 pF / 330 Ω |
|---|
| Long Duration Overvoltage | ISO 16750-2 Section 4.3.1.2 - Jumpstart |
|---|
| Transient Overvoltage | ISO 16750-2 Section 4.3.2 |
|---|
| Superimposed Alternating Voltage | ISO 16750-2 Section 4.4, Levels 3 and 4 |
|---|
| ISO 16750-2 | Section 4.5 |
|---|
| Momentary Drop in Supply Voltage | ISO 16750-2 Section 4.6.1 |
|---|
| Reset Behavior at Voltage Drop | ISO 16750-2 Section 4.6.2 |
|---|
| Reverse Voltage | ISO 16750-2 Section 4.7, Test case 2 |
|---|
| Open Circuit | ISO 16750-2 Section 4.9 |
|---|
| Short Circuit Protection | ISO 16750-2 Section 4.10.2 |
|---|
| Insulation Resistance | ISO 16750-2 Section 4.11 ,10 MΩ at 500 Vdc |
|---|
| Low Temperature Operating | ISO 16750-4 Section 5.1.1, TMIN: -40ºC |
|---|
| High Temperature Operating | ISO 16750-4 Section 5.1.2, TMAX : 85ºC |
|---|
| Thermal Step | ISO 16750-4 Section 5.2, Temp Range: -40 to 85ºC |
|---|
| Thermal Cycle | ISO 16750-4 Section 5.3, Temp Range: -40 to 85ºC |
|---|
| Humid Heat, Cyclic | ISO 16750-4 Section 5.6, Test 1 and 3 |
|---|
| Damp Heat, Steady-State | ISO 16750-4 Section 5.7 |
|---|
| Atmospheric Pressure | ISO 16750-4 Section 5.12, -100 m to 5000 m |
|---|
| Random Vibration | ISO 16750-3 Section 4.1 Test VII, Commercial Vehicles |
|---|
| Mechanical Shock | ISO 16750-3 Section 4.2, Shock Profile II |
|---|
| Handling Drop | ISO 16750-3 Section 4.3, 1 m drop |
|---|
| Withstand Voltage | ISO 16750-2 Section 4.12, 500 Vrms, 60 Hz for 60 s BES Series Datasheet | automation.honeywell.com/hss | 7 •WARNING |
|---|
| Honeywell warrants goods of its | PERSONAL INJURY |
|---|
| manufacture as being free of defective | DO NOT USE these products as safety |
|---|
| materials and faulty workmanship | or emergency stop devices or in any |
|---|
| during the applicable warranty period. | other application where failure of the |
|---|
| Honeywell’s standard product warranty | product could result in personal injury. |
|---|
| applies unless agreed to otherwise by | Failure to comply with these Honeywell in writing; please refer to your instructions could result in death or |
|---|
| order acknowledgment or consult your | serious injury. local sales office for specific warranty details. If warranted goods are returned |
|---|
| to Honeywell during the period of | •WARNING coverage, Honeywell will repair or replace, MISUSE OF |
|---|
| at its option, without charge those items | DOCUMENTATION |
|---|
| that Honeywell, in its sole discretion, | • The information presented in this |
|---|
| finds defective. The foregoing is buyer’s | product sheet is for reference only. |
|---|
| sole remedy and is in lieu of all other | Do not use this document as a |
|---|
| warranties, expressed or implied, | product installation guide. |
|---|
| including those of merchantability | • Complete installation, operation, and maintenance information and fitness for a particular purpose. is provided in the instructions In no event shall Honeywell be liable supplied with each product. for consequential, special, or indirect Failure to comply with these damages. instructions could result in death or |
|---|
| While Honeywell may provide information | serious injury. or engineering support for its products through Honeywell personnel, literature and website, it is the buyer’s sole responsibility to determine the suitability of the Honeywell product(s) for the buyer’s requirements. Specifications may change without notice. The information we supply is believed to be accurate as of this writing. However, Honeywell assumes no |
|---|
| For more information | responsibility for its use. |
|---|
| USA/Canada | +302 613 4491 |
|---|
| Latin America | +1 305 805 8188 |
|---|
| Europe | +44 1344 238258 |
|---|
| Japan | +81 (0) 3-6730-7152 |
|---|
| Singapore | +65 6355 2828 |
|---|
| Greater China | +86 4006396841 006023-3-EN | 3 | 01/26 |
|---|
| www.honeywell.com | © 2026 Honeywell International Inc. All rights reserved. |
|---|