| Acceptable | Acceptable feet (70 to 100 m) using optional |
|---|
| 靈敏度 | Percent Display DISTANCE between DISTANCE |
|---|
| between | BEAMLRK kit. |
|---|
| Setting | Obscuration Reading |
|---|
| detector and | detector and |
|---|
| reflector (ft) | reflector (m) Adjustment angle |
|---|
| Level 1 | 25% 25 16.4 to 120 5.0 to 36.6 ±10° horizontal and vertical. Note that |
|---|
| Level 2 | 30% 30 25 to 150 7.6 to 45.7 the optics move independently of the unit. |
|---|
| Level 3 | 40% 40 60 to 220 18.3 to 67 Sensitivity (6 levels) |
|---|
| Level 4 | 50% 50 80 to 328 24.4 to 100 6985sens.tbl • Level 1 — 25%. |
|---|
| Acclimate™ Level 1 | 30% to 50% A1 80 to 150 24.4 to 45.7 |
|---|
| Acclimate™ Level 2 | 40% to 50% A2 80 to 220 24.4 to 67 • Level 2 — 30%. • Level 3 — 40%. • Acclimate™ Level 6 — 40% to 50%. |
|---|
| above. | Fault condition (trouble) • Self-compensation limit reached. Alignment aid • Optical gunsight. • Integral signal strength indication. • Two-digit display. Indicators • Alarm — local red LED and remote alarm. • Trouble — local yellow LED and remote trouble. • Normal — local flashing green LED. |
|---|
| Reflector Mounting Guidelines | Test/reset features • Integral sensitivity test filter (BDT-SS only, requires external power supply). • Sensitivity filter (incremental scale on 6985mt1.wmf reflector). • Local alarm test switch. • Local alarm reset switch. • Remote test and reset switch (compatible with RTS451 and RTS451KEY test stations). Smoke detector spacing On smooth ceilings, 30 – 60 feet (9.1 to 18.3 m) between projected b |
|---|
| Page 2 of 4 | BD-SS and BDT-SS CS-2516 09/01/06 |
|---|
| Wiring | Environmental Specifications |
|---|
| Diagram | Temperature –22°F to 131°F (–30°C to 55°C). Humidity 10 – 93% RH noncondensing. Electrical Specifications Voltage 15 to 32 VDC. Average standby current 24 VDC: 2 mA maximum (LED flashing, g2516w1.wmf SLC @ 24 V). LED current 6.5 mA maximum. Remote annunciator current 11.2 mA maximum. Average current during testing 500 mA maximum. Alarm current 24 VDC; 8.5 mA maximum (LED on). Trouble/fault current |
|---|
| Switch | Add to standby current; 100 mA maximum. |
|---|
| Locations | Alignment mode current 24 VDC; 20 mA maximum. External supply (BDT-SS only) Voltage: 15 to 32 VDC. Current: 0.5 A maximum. Remote output (alarm) Voltage: 15 to 32 VDC. NOTE: Output voltage is the same as device input voltage. Current: 15 mA maximum, 6 mA minimum. NOTE: Output current is limited by 2.2K ohm resistor. Heater kit BEAMHK Voltage: 15 to 32 V. Current: 92 mA maximum @ 32 V (heater only) |
|---|
| Wiring Diagram (with RTS451/KEY) | consumption (per reflector): nominal 7.7 W @ 24 V; maximum 15.0 W @ 32 V. BD-SS / BDT-SS Mechanical Specifications Detector dimensions 10.0" H x 7.5" W x 3.3" D (254 mm H x 191 mm W x 84 mm D). Reflector dimensions For 16' to 230' (5 to 70 m) applications: 7.9" x 9.1" (200 x 230 mm). For applications beyond 230'/70 m: 15.7" x 18.1" (400 x 460 mm). |
|---|
| BD-SS and BDT-SS | CS-2516 09/01/06 Page 3 of 4 |
|---|
| Alignment Adjustment Locations | Housing Screw Locations |
|---|
| Parts List | Ordering Information |
|---|
| Item | Quantity BD-SS Intelligent beam smoke detector |
|---|
| Transmitter/receiver unit ....... 1 | BD-SSA Same as BD-SS with ULC Listing. |
|---|
| Paintable trim ring ................. 1 | BDT-SS Intelligent beam smoke detector with integral |
|---|
| Plug-in terminal blocks ........... 3 | BDT-SSA Same as BDT-SS with ULC Listing. tions in excess of 230 ft/70 m). |
|---|
| BEAMMMK | Multi-mount kit (provides ceiling or wall mount |
|---|
| Orange sticky paper ................ 1 | capability with increased angular adjustment). |
|---|
| BEAMSMK | Surface-mount kit. |
|---|
| RTS451 | Remote test station. |
|---|
| RTS451KEY | Remote test station with key lock. |
|---|
| BEAMHK | Heating kit for use with the transmitter/receiver unit of BDT-SS. For prevention of condensation. |
|---|
| BEAMHRK | Heating kit for use with the reflector of BDT-SS. For prevention of condensation. Gamewell-FCI 12 Clintonville Road Acclimate™ is a trademark of System Sensor, a Honeywell company. SmartScan™ is a trademark of Gamewell. Northford, CT 06472-1610 Phone: 203-484-7161 Specifications and wiring information are provided for information only and are Fax: 203-484-7118 believed to be accurate. Gamewell-FCI |
|---|
| www.gamewell-fci.com | Data and design are subject to change without notice. Installation and wiring instructions shipped with the product shall always be used for actual installation. |
|---|
| A Honeywell Company | For more information, contact Gamewell-FCI. © 2006 Gamewell-FCI |
|---|
| Page 4 of 4 | BD-SS and BDT-SS CS-2516 09/01/06 |
|---|