| Features | PK-411UD programming software, without ever compromis- ing monitoring protection at the protected premises (model 411UD only) • Integral piezo sounder with local silence switch control panel for: • One Form-C relay, fully programmable – Fire Alarm • Complies with NFPA 72 (Central Station and Remote Sta- – Fire Trouble tion [DACT only - not polarity reversal] Fire Alarm Systems) – Fire Supervisory |
|---|
| – Process Monitoring | (17.376 cm) W x 4.595" (11.671 cm) H x 1.0" (2.54 cm) D – AC Power Loss |
|---|
| – Security Alarm | Host Panel Compatibility |
|---|
| – Other (Fire and Non-Fire Events) | Host panels must include AC Fail Delay option to meet NFPA |
|---|
| feature | Housing lic switched telephone network (leased phone lines are not ing measuring only 6.841" (17.376 cm) W x 4.595" (11.671 |
|---|
| required) | cm) H x 1.0" (2.54 cm) D. The housing enclosure consists of |
|---|
| ADEMCO Contact ID format | secured by two captive screws. The overlay includes large areas to independently mark programming options for the three or four channels (inputs), relay, and also includes printed addition to vital system status of the host control panel: terminal and diagnostic LED designations. – DACT troubles |
|---|
| – Telephone line 1 and 2 voltage fault | Phone Line Connections – Primary or Secondary Central Station communication Two modular phone connections on the 411 Series are acces- fault sible with the cover in place and provide connections for two |
|---|
| – System off-normal | separate telephone lines using standard RJ31X or RJ38X |
|---|
| – 24-hour normal test | jacks. Both telephone lines are constantly supervised for |
|---|
| – 24-hour abnormal test | proper operation and integrity. If one phone line goes into fault while the other is working, a report is sent to the central or remote station. accepting up to 20-digit Central Station telephone numbers cess monitoring, and others Diagnostic LEDs • DACT Trouble (visible with front cover in place) (411UD). DF-51735:A2 • 3/19/2015 — Page 1 of 4 |
|---|
| • | Short-circuit current: 3.9 mA per channel/input. |
|---|
| Specifications | • Restricted to 20 feet (6 m) in conduit and in the same room |
|---|
| Listings and Approvals: | **NOTE: Channels/inputs do NOT support two-wire smoke detec- tors. ters. |
|---|
| lence: 0.4 B. | this document. In some cases, certain modules or applications 411: Three-channel, dual-line, slave Digital Alarm Communi- ble and power-limited 24 VDC (nominal) power must be silence switch. Includes housing, operating and programming supplied at TB1 Terminals 4(+) and 5(-). UL-listed operating instructions. Requires PRO-411 hand-held DACT programmer range is 17 to 28 VDC. Current requirements are |
|---|
| nected, and Lamp Test active. | PK-411UD: 411UD programming software; available for down- |
|---|
| Channels/Inputs:** | load at www.firelite.com or ships on PK-CD. programming software kit (for use with 411UD only). MCBL-7: DACT phone cord, seven feet long (two required). |
|---|
| Normally Open contact to trigger. | NOTE: For information about 411UDAC, see DF-60796. Osborne Hoffman Silent Knight Silent Knight System III (7) CP220FB (1) MX8000 (10) MR-2000 (9) Radionics MLR-2 (8) Surguard Surguard 2000E (5) Ademco Ademco Surgard 9000 (3) 9800 (4) 6600 (6) 685 (2) Format # FBI (Addresses 20 and 50) 0 4+1 Ademco Express 1 4+2 Ademco Express 2 3+1/Standard/1800/2300 |
|---|
| A | 4+2/Standard/1800/2300 |
|---|
| B | 4+2/Expanded/1800/2300 |
|---|
| C | 4+2/Standard/1900/1400 |
|---|
| D | 4+2/Expanded/1900/1400 |
|---|
| E | Ademco Contact ID DF-51735:A2 • 3/19/2015 — Page 3 of 4 trademark of Honeywell International Inc. Windows® is a registered trademark of Microsoft Corporation. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information |
|---|