| buildings, and factories. | • Built-in alert tone generators with steady, slow whoop, high/ low, or chime tone capability. |
|---|
| Standard Features | • Field-selectable lead-in/trailing tone selection. |
|---|
| • Listed to UL Standard 864, 9th edition. | • Alert tone selection may be field-programmed to conform Z (Class A) or Style Y (Class B) speaker circuit (expandable (Temporal Pattern), per NFPA. |
|---|
| to 50 watts using the ACC-AAM25). | • Speaker zone control via CMD inputs or keypad. |
|---|
| service. | dently field-programmable for activation by polarity reversal |
|---|
| vation by an FACP. | • Zone 1 switch-programmable for All-Call operation. grammed for activation by a Notification Appliance Circuit Microphone Trouble, Message Generator Trouble, Tone (NAC) or contact closure. Generator Trouble, Amplifier Fault, and others. |
|---|
| • Manual deactivation of speaker zones. | voice system while in active (alarm) state. 30-second messages. – Three 20-second messages. – • Fully supervised in Standby and Active states, including Four 15-second messages. – Five 12-second messages. integral microphone, amplifier output, message generator, |
|---|
| • Microphone time-out feature. | speaker wiring, and tone generators. |
|---|
| speaker; and remote microphone. | • Auxiliary power output provides local power for addressable |
|---|
| prerecorded emergency evacuation message. | • Compatible with all Fire•Lite FACPs, as well as other manu- |
|---|
| microphone or the audio input jack. | • Background music capability (requires AHJ approval). DF-52381:A1 • 1/13/10 — Page 1 of 4 power per amplifier is reduced to 20 watts. This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH |
|---|
| Optional Modules | (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the The ACC-25/50 complies with the following standards: NFPA These listings and approvals apply to the basic ACC-25/50. In |
|---|
| overview of batteries. | tory for latest listing status. |
|---|
| one FC-RM per system. | • MEA: 341-03-E (ACC-25/50, ACC-AAM25) |
|---|
| Specifications | Product Line Information |
|---|
| voltage: 10.5 – 29 VDC. | Control Panel with integral commercial microphone, digital B speaker circuits. Module with single Class A or Class B speaker circuit. |
|---|
| mA. | FC-XRM70: optional 70.7 VRMS Converter Module (one required per amplifier). FC-LPS: optional Local Playback Speaker. |
|---|
| acid batteries only. | BAT Series: Two batteries required. See FACP manual for specific current requirements. See data sheet DF-52397 for |
|---|
| Float-charge voltage: 27.6 V. | overview of batteries. |
|---|
| Maximum charge current: 800 mA. | ACC-TR: Optional trim ring for semi-flush mounting. |
|---|
| Maximum battery charging capacity: 18 AH. | FC-RM: Optional remote microphone, includes backbox. Only one FC-RM per system. Application Examples |
|---|
| includes door. | sages. Two typical application examples follow. |
|---|
| Controls and Indicators | One Speaker Circuit |
|---|
| LED INDICATORS | Single output zone, single input circuit (SEE FIGURE 1). A 1. Power On (green). very basic application is one ACC-25/50 with one amplifier and 2. System Trouble (yellow). a single speaker circuit. This configuration is suitable for small facilities requiring no more than 25 watts of output power. A 3. Message Generator Trouble (yellow). single fire evacuation message will be initiated during an al |
|---|
| Supervisory. | message to the speaker circuit when the CMD1 input is acti- vated. The S5 DIP switch “5” is set to OFF; this selection acti- vates the CMD1 input by a reverse-polarity condition. CMD3, CMD4, and CMD5 inputs require end-of-line resistors. Keypad Example ACC-25/50 Figure 1: One 25 Watt Speaker Circuit |
|---|
| watt, P/N 75470. | panel and addressable control modules. Refer to manual for volt- age ranges, message control switch settings, and command input specifications. DF-52381:A1 • 1/13/10 — Page 3 of 4 |
|---|
| TWO SPEAKER CIRCUITS | CMD2 to direct the Fire Message to the Auditorium Speakers or Classroom Speakers. The S5 DIP switches “5” and “6” are |
|---|
| second fire evacuation message. | button(s), then press the Fire Message button. Alternately, use the microphone to make an announcement. To manually Keypad Example ACC-25/50 Figure 2: Two Speaker Circuits, Dual Output Zone, Dual Input Circuit |
|---|
| specifications. | ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Made in the U.S. A. |
|---|