| Keypad | 1 operation and 2 programming keys, 1 flashlight on/off Instantaneous reading • VOCs as ppm by volume or mg/m3 (3 in upper case for cubic) Sensor Specifications |
|---|
| Direct Readout | • STEL, TWA and PEAK Response |
|---|
| Gas Monitor | Range Resolution |
|---|
| • Battery and shutdown voltage | Time T90 |
|---|
| • Date, time, temperature | 0 to 9999 ppb 1 ppb <3s 95 dB (at 12”/30 cm) buzzer and flashing red LED to indicate exceeded preset limits 10 to 99 ppm 0.01 ppm <3s VOCs |
|---|
| • High: 3 beeps and flashes per second | 100 to 999 ppm 0.1 ppm <3s |
|---|
| • Low: 2 beeps and flashes per second | 1000 to 9999 ppm 1 ppm <3s Alarms • STEL and TWA: 1 beep and flash per second • Alarms latching with manual override or automatic reset MONITOR ONLY INCLUDES: • Additional alarm for low battery and pump stall |
|---|
| Highly resistant to EMI/RFI | • ppbRAE 3000 + Monitor EMI/RFI |
|---|
| Compliant with EMC Directive 89/336/EEC | • Wireless communication module built in, • IP-67 unit off and without flexible probe as specified IP Rating |
|---|
| • IP-65 unit running | • Charging/download adapter |
|---|
| Datalogging | Standard 6 months at one-minute intervals • Organic vapor zeroing kit • Tedlar® bag for calibration Two-point or three-point calibration for zero and span. |
|---|
| Calibration | Reflex PID TechnologyTM • Flex-I-Probe™ Calibration memory for 8 calibration gases • External filter • Internal, integrated flow rate at 500 cc/mn • Rubber boot with straps |
|---|
| Sampling Pump | • Alkaline battery adapter • Sample from 100’ (30m) horizontally and vertically • Lamp-cleaning and tool kit |
|---|
| Low Flow Alarm | • Auto pump shutoff at low-flow condition • Soft leather case • Download data and upload instrument set-up from PC through charging cradle or |
|---|
| Communication & | MONITOR WITH ACCESSORIES KIT: using BLE module and dedicated APP Data Download • Wireless data transmission through built-in RF modem • Hard transport case with pre-cut foam padding |
|---|
| Wireless Network | Mesh RAE Systems Dedicated Wireless Network • Charging/download cradle • 5 Porous metal filters and O-rings Up to 15 ft (5m) for BLE |
|---|
| Wireless Range | • Gas outlet port adapter and tubing EchoView Host: LOS > 660 ft (200 m) ProRAE Guardian & RAEMesh Reader: LOS > 660 ft (200 m) (Typical) OPTIONAL CALIBRATION KIT ADDS: ProRAE Guardian & RAELink3 Mesh: LOS > 330 ft (100 m) • US and Canada: UL, cUL, Classified as Intrinsically Safe for use in Class I, Division • 10 ppm isobutylene calibration gas, 34L 1 Groups A, B, C, D • Calibration regulator and |
|---|
| Temperature | -4° to 113° F (-20° to 50° C) COST-OF-OWNERSHIP PROGRAM: • 4-year repair and replacement warranty |
|---|
| Humidity | 0% to 95% relative humidity (non-condensing) • Annual maintenance service |
|---|
| Attachments | Durable black rubber boot with straps |
|---|
| For more information | Americas Asia Pacific |
|---|
| www.honeywellanalytics.com | Honeywell Analytics Distribution Inc. Honeywell Analytics Asia Pacific Tel: |
|---|
| www.raesystems.com | Tel: +1 847 955 8200 +82 (0) 2 6909 0300 |
|---|
| Toll free: +1 800 538 0363 | India Tel: +91 124 4752700 |
|---|
| Europe, Middle East, Africa | detectgas@honeywell.com China Tel: +86 10 5885 8788-3000 |
|---|
| Life Safety Distribution GmbH | Honeywell RAE Systems analytics.ap@honeywell.com |
|---|
| Tel: 00800 333 222 44 (Freephone number) | Phone: +1 408 952 8200 |
|---|
| Tel: +41 44 943 4380 (Alternative number) | Toll Free: +1 888 723 4800 Technical Services |
|---|
| gasdetection@honeywell.com | US: ha.us.service@honeywell.com Datasheet_ppbRAE 3000_+_DS-1018-_EN |
|---|
| ©2018 Honeywell International Inc. | AP: ha.ap.service@honeywell.com |
|---|