| Functions | RK-MCU |
|---|
| and fault diagnosis, etc. | Record and play |
|---|
| Automatic fault diagnosis | The unit allows temporary message recording via the PTT microphone or call station. The messages are stored on the internal 1 GB memory and will broadcast without configuration. This allows the system to be used for promotional applications where a message may need to be updated frequently. Cost-saving amplifier backup solution The RK-MCU has a built-in amplifier automatic switch-over function and |
|---|
| Scheduled broadcast with built-in timer | different applications. A minimum of one standby |
|---|
| • Integrated public | • Numerous user-friendly • Equipment cost savings • Built-in standard • Manages all public |
|---|
| address system | features to increase by implanting recorder, configuration allows the address and emergency |
|---|
| controller with built-in | operational efficiency: timer, audio monitor, system to be used broadcast devices on 500 W amplifier. plug and play, record and one-for-all backup directly following the system, providing |
|---|
| and play, interaction | amplifier solutions. installation. System device system status |
|---|
| between LCD and | functions can also be information and device |
|---|
| loudspeaker zones | • Supports both single |
|---|
| buttons, etc. | set via the configuration parameter modification |
|---|
| can be connected | and dual channel mode |
|---|
| software. | via the LCD screen. |
|---|
| with a maximum power | • Built-in 500 W Class-D • 2 auxiliary inputs and 1 |
|---|
| rating of 500 W for | power amplifier. • Built-in 1 GB Flash • Flexible power amplifier MIC/LINE input. |
|---|
| each speaker line. | memory and 4 GB SD redundancy. A single • Supports external |
|---|
| • Capable of integration | card, which can be spare amplifier can |
|---|
| • 10 dry contact inputs | power amplifiers. |
|---|
| with third-party | used to store audio back up all amplifiers with supervision and |
|---|
| systems, such as fire | files, recording files, in the system. 8 dry contact outputs. |
|---|
| alarm systems, through | configuration data, |
|---|
| the dry contact. | and log files, etc. |
|---|
| PARAMETERS | VALUES PARAMETERS VALUES |
|---|
| MAIN POWER SUPPLY VOLTAGE | AC 100-240V 50/60 Hz LOUDSPEAKER CIRCUITS |
|---|
| BACKUP POWER SUPPLY VOLTAGE | 21.5 VDC-28.5 VDC OUTPUT CHANNELS 8 (with group A and group B) |
|---|
| MAIN POWER SUPPLY FUSE | T10AH 250V MAXIMUM LOUDSPEAKER LOAD 500 W |
|---|
| 功耗 | <740W CONTACT INPUT/OUTPUT |
|---|
| MICROPHONE INPUT | CONTACT INPUTS 10 contact input interfaces with supervision |
|---|
| INPUT SENSITIVITY | -59 ± 3 dBV CONTACT OUTPUTS 8 (NO, NC & COM), “fault” output, alarm output |
|---|
| 頻率響應 | 100-14 kHz, ± 3 dB MAX. WORKING VOLTAGE AC 250 V/DC 30V FOR OUTPUTS |
|---|
| 信噪比 SNR | >50 dB (A-weighted) |
|---|
| MAX. WORKING CURRENT | 2.5 A |
|---|
| AUXILIARY INPUT | FOR OUTPUTS |
|---|
| CHANNELS | 2 OTHERS |
|---|
| INPUT IMPEDANCE | 10 KΩ MONITORING LOUDSPEAKER 2 W/8Ω |
|---|
| MIC/LINE INPUT | OPERATING CONDITIONS |
|---|
| PHANTOM POWER | -24 VDC, switchable PRODUCT DIMENSION (W×H×D) 482 mm × 133.5 mm × 420 mm (18.98 in. × 5.26 in. × 16.53 in.) |
|---|
| 包裝尺寸 | 580 mm × 279 mm × 552 mm |
|---|
| MAX. POWER OUTPUT | 500 W (W×H×D) (22.83 in. × 10.98 in. × 21.73 in.) |
|---|
| OUTPUT SIGNAL | 70V (CH1A) |
|---|
| 淨重 | 24.25 lbs. |
|---|
| THD | <0.1% |
|---|
| 毛重 | 31.08 lbs. |
|---|
| OUTPUT CHANNELS | Channel 1, Channel 2, and recording output WA RR A N T Y |
|---|
| CATEGORY | REGION CERTIFICATION |
|---|
| CONTROL SIGNAL | Self-test signal, amplifier fault signal, and power saving |
|---|
| control signal | SAFETY Europe CE Certified |
|---|
| LOUDSPEAKER CIRCUITS | SAFETY Global CB Certified |
|---|
| MAXIMUM LOUDSPEAKER LOAD | 500 W SAFETY North America UL60065 Certified AMPLIFIER CONTROL INTERFACE |
|---|
| DESCRIPTION | MODEL# changes in product design |
|---|
| Tel:+1.800.323.4576 | DO-60984 | 11/17 |
|---|
| www.honeywell.com | © 2017 Honeywell International Inc. |
|---|