| configuration, setup, | significant savings in startup costs and ongoing operations. Our global partner and maintenance network and dedicated application specialists are able to help you make the right |
|---|
| and reporting | choices for your industry. |
|---|
| • Large color touchscreen LCD | With everything at your fingertips, you can take ownership of your system and operate it with confidence, helping to ensure the safety |
|---|
| at a glance | of your people and the productivity of your site. |
|---|
| Want to | Want peace |
|---|
| fully utilize | of mind? your controller? |
|---|
| Built for ease – | Engineered to the highest |
|---|
| so you can operate it | standards of quality and |
|---|
| with confidence | reliability Want a simple end-to-end |
|---|
| solution? | Want to simplify system |
|---|
| Easy ordering, installation, | setup? and servicing from the |
|---|
| gas detection experts | With the intuitive, ergonomic touchscreen, setup couldn’t be easier Want to make fast, informed decisions? Want to System status at a glance know what’s |
|---|
| when time is critical | going on? View real-time and historical data, analyze readings, and much more Large color touchscreen LCD with multilingual options Clear common status indicators (green, yellow, red) |
|---|
| Built-in sounder | Mute/Reset Individual channel status indicators (green, yellow, red) |
|---|
| Honeywell Analytics’ one system | XNX universal |
|---|
| Relays, actuators, and | transmitter |
|---|
| solution to meet your safety | audio/visual alarms |
|---|
| detection systems across a wide range of | Cloud |
|---|
| mA oop | sensors sensors End user Key Touchpoint Plus Control Touchpoint Plus Expansion Unit Gas Detector Audible & Visual Alarm 1. Main module 2. Input module 7 5 4 3. Relay output module 4. mA output module 6 5. Power supply 10 3 6. Display module 7. Touchscreen 9 1 2 8. Backup battery 9. Modbus TCP/Web 10. Modbus RTU Not included in Expansion Unit |
|---|
| Provided As Standard | Alarm 1 Alarm 2 Fault Visible Failure Configurable 4-20mA 4-20mA alarm drives |
|---|
| • Common alarm outputs, one for | Dedicated Audible/Visual Alarm Outputs System State Relays fault and two configurable 12 12 4 4 |
|---|
| • Datalogging to SD card | Outputs Outputs Outputs Outputs |
|---|
| Alarm 1 | Alarm 2 Alarm 3 1 0 0 SD Card |
|---|
| Fault | Warning Inhibit 0 0 0 |
|---|
| • Optional backup battery | Input/Output Remote 8 mV; 2 mA and 2 mV; 4 mA and 4 mV Buzzer Mute/Reset |
|---|
| Remote | 01 02 03 04 05 06 07 08 |
|---|
| • Optional expansion unit for up to | Reset 09 10 11 12 13 14 15 16 16 inputs |
|---|
| • Optional RS485 Modbus RTU | Power Supply Backup Battery 110/220 VAC 18-32 VDC 2, 4, or 8 Inputs 2-Wire 4-20 mA 3-Wire 4-20 mA 3-Wire mV Bridge 15 6 m m Touchpoint Plus is supplied with 13 pre-drilled and sealed cable entries for PG16/M20 glands. Direct Surface Mounting 426m Optional Mounting Plate Sensor Connection - Compatible with a wide range of field devices +24 Vdc External 24 VDC GND Supply Touchpoint Plus mA Input Mod |
|---|
| + | +V |
|---|
| +24 vdc | +24 vdc +24 Vdc Sensitive |
|---|
| +VE | +VE +VE 4-20mA Bead Sensor |
|---|
| Signal | Signal Sensor Sensor Sensor |
|---|
| SIG | SIG 4-20mA SIG Non- 4-20mA 66 Ω Sensitive |
|---|
| -VE | 66 Ω 66 Ω Bead -V |
|---|
| Series 3000 MkII/MKIII | intrusive local operation, in-field adjustment, power |
|---|
| RAEGuard II PID | up to 8 devices directly from Touchpoint Plus IAQPoint2 |
|---|
| XNX Universal Transmitter | High-integrity devices, specialized configuration, |
|---|
| Searchline Excel | in-field adjustment, monitor up to 8 devices with external |
|---|
| E3Point, EC F9, IR F9 | power as required Note: Other field devices available on request. Some devices are not available in all regions. |
|---|
| GENERAL SPECIFICATION | GENERAL SPECIFICATION |
|---|
| Up to 8 channels with base unit, up to 16 | Available I/O Modules (continued) |
|---|
| channels with expansion unit | Catalytic-type flammable gas detectors 2- or 3-wire, mA, mV, max. 15 W per mV Input (Honeywell models). 2-/4-/8-channel |
|---|
| channel, max. 40 W total (with dedicated | modules, 10/12/16 with expansion unit |
|---|
| A/V drive)/68 W total (without dedicated | 2-channel mA + 2-channel mV module or |
|---|
| A/V drive) | Dual Input 4-channel mA + 4-channel mV module 426 mm × 300 mm × 156 mm 12 or 24 relay outputs, NO/C/NC (16.8” x 11.8” x 6.1”) changeover, 1.7 A @ 30 VDC/250 VAC, Relay Output |
|---|
| Housing Material | Polycarbonate ABS user-configurable - energized/de-energized, latching/non-latching, time delay Max. 8.5 kg (18.7 lb), max. 17 kg (37.4 lb) |
|---|
| 重量 | 4 or 8 isolated repeated mA outputs, |
|---|
| with expansion unit | 4-20mA Output 0-22 mA, 0-100% FSD = 4-20 mA |
|---|
| Common Inputs | Remote reset, remote inhibit |
|---|
| Display | 7’’ color LCD touchscreen. Graphic User Interface 4 powered A/V outputs for alarms and fault, Common Outputs 3 LEDs for master indicators. LED for each 3 common alarm outputs |
|---|
| Visual Indicators | channel. Green: Normal; Yellow: Fault: Approvals Inhibit; Red: Alarm |
|---|
| Audible Alarm | ≥ 70dB @ 1 m (3.28 ft) Electromagnetic EMC/RFI (EN 50270:2015) |
|---|
| Compatibility and | LVD (EN 61010-1:2010) |
|---|
| 按鈕 | Common for reset/mute operation CSA-C22.2 No. 61010-1-04 |
|---|
| Electrical Safety | UL 61010-1 (3rd Edition) and 508 English, French, German, Italian, Dutch, |
|---|
| Spanish, Portuguese, Russian, Chinese | EN 50271:2010; EN 60079-29- |
|---|
| Power Supply* | 1:2007/2016; EN 45544-1 /-2/-3:2015; Performance EN 50104:2010 C22.2 No. 152-M1984, |
|---|
| AC Power | 110/220 VAC, 50-60 Hz Manual switching ISA 12.13.01 |
|---|
| DC Power | 18 to 32 VDC (+/-10%) Typical 24 VDC IEC 61508:2010 Ed.2 SIL2, EN Max. 105 W (including detector and external Safety Integrity |
|---|
| 功耗 | 50271:2010 devices), max. 210 W with expansion unit Class I, Division 2, Group A, B, C, and D, |
|---|
| Environmental | Hazardous Location or non-hazardous only -10 °C to +55 °C (14 °F to +131 °F) |
|---|
| Marine | MED (Item No.: 3.54) |
|---|
| Operating | continuous, up to 95% RH (non- |
|---|
| condensing), IP65, and NEMA 4X | Others |
|---|
| Instrument -25 °C to +60 °C (-13 °F to + | 22.2 V Lithium Ion Battery, 2600 mAh |
|---|
| Storage | Backup Battery 140 °F), up to 95% RH (non-condensing) capacity (>30 minutes for typical system) |
|---|
| Available I/O Modules | Datalogging Configuration, logged events, and data 2- or 3-wire, 2/4/8 channel modules, MODBUS TCP, WEB monitoring, and 10/12/16 with expansion unit MODBUS RTU * Basic and expansion units each require a power supply ** Not available in expansion unit ORDERING INFORMATION Output Option 4: 4ch mA Output 8: 8ch mA Output |
|---|
| N: No mA Output | Battery Power |
|---|
| Mounting Type | B: Backup Battey |
|---|
| A: AC | N: None |
|---|
| D: DC | W: Wall Mount Product Name |
|---|
| T PPLB AWA 8 S 8BNNN | Future Use Communication** N: None |
|---|
| Unit Type | Input Option R: MODBUS TCP+WEB(read) |
|---|
| B: Base Unit | A2: 2ch mA Input Communication** T: MODBUS TCP |
|---|
| E: Expansion Unit | A4: 4ch mA Input |
|---|
| A8: 8ch mA Input | R: MODBUS RTU |
|---|
| V2: 2ch mV Input | N: None V4: 4ch mV Input V8: 8ch mV Input |
|---|
| D4: 2ch mA + 2ch mV input | Relay Option D8: 4ch mA + 4ch mV input S: 12 Relays D: 24 Relays N: No Relays |
|---|
| Europe, Middle East, Africa | Asia Pacific |
|---|
| Life Safety Distribution GmbH | Honeywell Industrial Safety |
|---|
| Tel: 00800 333 222 44 (Freephone number) | Tel: +82 (0) 2 6909 0300 |
|---|
| Tel: +41 44 943 4380 (Alternative number) | India Tel: +91 124 4752700 |
|---|
| Americas | Technical Support |
|---|
| Honeywell Analytics Distribution Inc. | EMEA: HAexpert@honeywell.com |
|---|
| Tel: +1 847 955 8200 | US: ha.us.service@honeywell.com |
|---|
| Toll free: +1 800 538 0363 | AP: ha.ap.service@honeywell.com |
|---|