ARUBA DS-6000SERIES 安裝、保養、維修

DS-6000SERIES

裝WIFI | 裝ROUTER | 裝FIREWALL — 硬件連工程一站式

產品簡介

aruba DS-6000SERIES 為HPE Aruba Networking,HKEZIT 提供原廠行貨連保養、上門安裝、調試及使用教學一站式服務。詳細規格以下方原廠 Datasheet 欄位為準,歡迎聯絡我們查詢 DS-6000SERIES 香港價格連安裝報價。

  • HPE Aruba Networking 6000 48G:HPE Aruba Networking 6000 48G Class4 PoE 4SFP 370W Switch
  • CL4 4SFP 740W Sw (R9Y03A):4SFP Switch (R8N86A) (R8N85A)
  • Description:48x 10/100/1000BASE-T Ports 48x 10/100/1000BASE-T Ports 48x
  • Supports PoE Standards IEEE 802.3af,:Supports PoE Standards IEEE 802.3af, 1x USB Type-A Host port
  • Power supplies:Fixed power supply Fixed power supply Fixed power supply
HKEZIT 提供原廠行貨保養。硬件連專業安裝、設定及使用教學一站式報價,無需自行研究安裝與設定。我們同時承接裝WIFI、裝ROUTER、裝FIREWALL工程,硬件與工程同一團隊負責。
查詢價格連安裝
DS-6000SERIES aruba HPE Aruba Networking 產品圖片

詳細規格

HPE Aruba Networking 6000 48GHPE Aruba Networking 6000 48G Class4 PoE 4SFP 370W Switch
CL4 4SFP 740W Sw (R9Y03A)4SFP Switch (R8N86A) (R8N85A)
Description48x 10/100/1000BASE-T Ports 48x 10/100/1000BASE-T Ports 48x 10/100/1000BASE-T Ports 4x 1G SFP Ports 4x 1G SFP ports 4x 1G SFP ports 1x USB-C Console Port
Supports PoE Standards IEEE 802.3af,Supports PoE Standards IEEE 802.3af, 1x USB Type-A Host port 802.3at 802.3at 1x USB-C console port 1x USB-C Console Port 1x USB Type-A Host port 1x USB Type-A Host port
Power suppliesFixed power supply Fixed power supply Fixed power supply
Up to 740W of Class 4 PoE PowerUp to 370W of Class 4 PoE Power
FansFixed fans Fixed fans Fixed fans
尺寸(H) 4.39 cm x (H) 4.39 cm (H) 4.39 cm (W) 44.25 cm x (W) 44.2 cm (W) 44.2 cm (D) 32.42 cm (D) 30.48 cm (D) 24.74 cm (1.73” x 17.42” x 12.77”) (1.73” x 17.4” x 12.0”) (1.73” x 17.4” x 9.74”)
Configuration Weight4.7 kg (10.36 lbs) 5.02 kg (11.07 lbs) 3.42 kg (7.54 lbs)
CPUDual Core ARM Cortex A9 @ 1.016 GHz Dual Core ARM Cortex A9 @ 1.016 GHz Dual Core ARM Cortex A9 @ 1.016 GHz
Memory and Flash4 GB DDR3 4 GB DDR3 4 GB DDR3 16GB eMMC 16 GB eMMC 16 GB eMMC
Packet Buffer1 MB 1 MB 1 MB
Model Switching Capacity104 Gbps 104 Gbps 104 Gbps
Model Throughput Capacity77.3 Mpps 77.3 Mpps 77.3 Mpps
Average Latency (LIFO-64-1Gbps: 1.9 µs 1 Gbps: 1.9 µSec 1 Gbps: 1.9 µSec
Switched Virtual Interfaces16 16 16
IPv4 Host Table (ARP)1,024 1,024 1,024
IPv6 Host Table (ND)512 512 512
IPv4 Unicast Routes512 512 512
IPv6 Unicast Routes512 512 512
Data sheetPage 7 HPE Aruba Networking 6000 48G
MAC Table Capacity8,192 8,192 8,192
IGMP Groups512 512 512
MLD Groups512 512 512
IPv4/IPv6/MAC ACL Entries256 / 128 / 256 256 / 128 / 256 256 / 128 / 256
工作溫度32°F to 113°F (0°C to 45°C) up to 5000 ft 32°F to 113°F (0°C to 45°C) up to 5000 ft 32°F to 113°F (0°C to 45°C) up to 5000 ft (1.5 km) derate by 1°C for every 1000 ft (1.5 km) derate by 1°C for every 1000 ft (1.5 km) derate by 1°C for every 1000 ft (305 m) from 5000 ft (1.5 km) to 10000 (305 m) from 5000 ft (1.5 km) to 10000 (305 m) from 5000 ft (1.5 km) to 10000
ft (3.0 km)ft (3.0 km) ft (3.0 km)
Operating Relative Humidity5% to 95% at 104°F (40°C) non-condensing 15% to 95% at 104°F (40°C) non- 15% to 95% at 104°F (40°C) non-
condensingcondensing
Non-Operating-40°F to 158°F (-40°C to 70°C) up to -40°F to 158°F (-40°C to 70°C) up to -40°F to 158°F (-40°C to 70°C) up to 15000 ft (4.6 km) 15000 ft (4.6 km) 15000 ft (4.6 km)
Non-Operating Storage5% to 90% @ 149°F (65°C) non-condensing 15% to 90% @ 149°F (65°C) non- 15% to 90% @ 149°F (65°C) non-
相對濕度condensing condensing
Max Operating Altitude10000 feet (3 km) Max 10000 feet (3 km) Max 10000 feet (3 km) Max
Max Non-Operating Altitude15000 feet (4.6 km) Max 15000 feet (4.6 km) Max 15000 feet (4.6 km) Max
AcousticSound Power, LWAd = 4.95 Bel Sound Power, LWAd = 4.3 Bel Sound Power, LWAd = 3.6 Bel
Sound Pressure, LpAm (Bystander)Sound Pressure, LpAm (Bystander) = 29.8 Sound Pressure, LpAm (Bystander) = 24.6
= 35.91 dBdB dB
Primary AirflowSide-to-side Side-to-side Side-to-side
Frequency50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
AC Voltage100-127 VAC / 200-240 VAC 100-127 VAC / 200-240 VAC 100-127 VAC / 200-240 VAC
Current9.2 A / 4.9 A 4.9 A / 2.4 A 0.8 A / 0.5 A
功耗Idle: 37.5W Idle: 30.6W Idle: 20.6W
Max Power (w/ PoE): 890WMax Power (w/ PoE): 480W
IEC / EN 62368-1: 2014IEC / EN 62368-1: 2014 IEC / EN 62368-1: 2014
IEC / EN 62368-1: 2018IEC / EN 62368-1: 2018 IEC / EN 62368-1: 2018
UL 62368-1: 2019, 3rd Ed.,UL 62368-1: 2014, 2nd Ed., UL 62368-1: 2014, 2nd Ed.,
CSA C22.2 No. 62368-1:19, 3rd Ed.CSA C22.2 No. 62368-1:14, 2nd Ed., CSA C22.2 No. 62368-1:14, 2nd Ed.,
VCCI-CISPR 32, Class AVCCI-CISPR 32, Class A VCCI-CISPR 32, Class A
CNS 15936, Class ACNS 15936, Class A CNS 15936, Class A
FCC CFR 47 Part 15, Class A;FCC CFR 47 Part 15, Class A; FCC CFR 47 Part 15, Class A;
EN 55032:2015 / A11:2020 / CISPR-32,EN 55032:2015 / A11:2020 / CISPR-32, EN 55032:2015 / A11:2020 / CISPR-32,
Class AClass A Class A
ICES-003 Issue 7: 2020, Class AICES-003 Issue 7: 2020, Class A ICES-003 Issue 7: 2020, Class A
AS/NZS CISPR 32: 2015, Class AAS/NZS CISPR 32: 2015, Class A AS/NZS CISPR 32: 2015, Class A
IEC / EN 60825-1:2014, Class 1IEC / EN 60825-1:2014, Class 1 IEC / EN 60825-1:2014, Class 1
Class 1 Laser Products / Laser Klasse 1Class 1 Laser Products / Laser Klasse 1 Class 1 Laser Products / Laser Klasse 1 (Applicable for accessories - Optical (Applicable for accessories - Optical (Applicable for accessories - Optical
Transceivers only)Transceivers only) Transceivers only)
GenericCISPR 35: 2016 CISPR 35: 2016 CISPR 35: 2016
ENEN 55035:2017 / A11:2020 EN 55035:2017 / A11:2020 EN 55035:2017 / A11:2020
ESDIEC 61000-4-2 IEC 61000-4-2 IEC 61000-4-2
RadiatedIEC 61000-4-3 IEC 61000-4-3 IEC 61000-4-3
EFT/BurstIEC 61000-4-4 IEC 61000-4-4 IEC 61000-4-4
SurgeIEC 61000-4-5 IEC 61000-4-5 IEC 61000-4-5
ConductedIEC 61000-4-6 IEC 61000-4-6 IEC 61000-4-6
Voltage dips and interruptionsIEC 61000-4-11 IEC 61000-4-11 IEC 61000-4-11
HarmonicsIEC / EN 61000-3-2 EN 61000-3-2, IEC 61000-3-2 EN 61000-3-2, IEC 61000-3-2
FlickerIEC / EN 61000-3-3 EN 61000-3-3, IEC 61000-3-3 EN 61000-3-3, IEC 61000-3-3
Mounts in an EIA-standard 19-inch telcoMounts in an EIA-standard 19-inch telco Mounts in an EIA-standard 19-inch telco
rack or equipment cabinet (rack-mountingrack or equipment cabinet (rack-mounting rack or equipment cabinet (rack-mounting kit available); horizontal surface mounting; kit included); horizontal surface mounting. kit included); horizontal surface mounting. wall mounting
HPE Aruba Networking 6000 24GHPE Aruba Networking 6000 12G HPE Aruba Networking 6000 24G
Class4 PoE 4SFP 370W SwitchClass4 PoE 2G/2SFP 139W Switch 4SFP Switch (R8N88A) (R8N87A) (R8N89A)
Up to 370W of Class 4 PoE PowerUp to 139W of Class 4 PoE Power
IPv4/IPv6/MAC ACL256 / 128 / 256 256 / 128 / 256 256 / 128 / 256
Operating Relative15% to 95% at 104°F (40°C) non- 15% to 95% at 104°F (40°C) non- 15% to 95% at 104°F (40°C) non-
Humiditycondensing condensing condensing
Max Non-Operating15000 feet (4.6 km) Max 15000 feet (4.6 km) Max 15000 feet (4.6 km) Max
Sound Pressure, LpAm (Bystander) = 24.3Sound Pressure, LpAm (Bystander) = Sound Pressure, LpAm (Bystander) =
dB20.9 dB 0 dB
Power Consumption (230Idle: 22.9W Idle: 15.4W Idle: 16W
VAC)Max Power (w/o PoE): 32.7W Max Power (w/o PoE): 33W Max Power (w/o PoE): 21.9W
Max Power (w/ PoE): 455WMax Power (w/ PoE): 170W
UL 62368-1: 2014, 2nd Ed.,UL 62368-1: 2014, 2nd Ed., UL 62368-1: 2014, 2nd Ed.,
CSA C22.2 No. 62368-1:14, 2nd Ed.,CSA C22.2 No. 62368-1:14, 2nd Ed., CSA C22.2 No. 62368-1:14, 2nd Ed.,
Power frequency magnetic IEC 61000-4-8IEC 61000-4-8 IEC 61000-4-8
Voltage dips andIEC 61000-4-11 IEC 61000-4-11 IEC 61000-4-11
Standards and protocols• RFC 4251 SSHv6 Architecture • RFC 4252 SSHv6 Authentication • RFC 1591 DNS (client) • RFC 4253 SSHv6 Transport Layer • SNMP RFC3411-3418 • RFC 4254 SSHv6 Connection • SSHv1/SSHv2 Secure Shell • RFC 4293 MIB for IP • IEEE 802.1D MAC Bridges • RFC 4419 Key Exchange for SSH • IEEE 802.1p Priority • RFC 4443 ICMPv6 • IEEE 802.1Q VLANs • RFC 4861 IPv6 Neighbor Discovery • IEEE 802.1s Multiple Spannin
• IEEE 802.3at Power over Ethernetieee8021BridgePortMrpJoinTime, ieee8021BridgePortMrpLeaveTime,
• IEEE 802.3az Energy Efficient Ethernetieee8021BridgePortMrpLeaveAllTime)
• IEEE 802.3x Flow Control• RFC 2737 Entity MIB
• RFC 768 UDP• RFC 2863 The Interfaces Group MIB
• RFC 783 TFTP Protocol (revision 2)• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
• RFC 792 ICMP• RFC 1098 A Simple Network Management Protocol
• RFC 793 TCP(SNMP)
• RFC 826 ARP• ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED) • RFC 1350 TFTP Protocol (revision 2) • SNMPv1/v2c/v3 • RFC 2131 DHCP client • RFC 2819 Four groups of RMON: 1 (statistics), 2 • RFC 4330 Simple Network Time Protocol (SNTP) v4 (history), 3 (alarm) and 9 (events)
• RFC 951 BOOTP (VLAN 1 Only)• RFC 1098 A Simple Network Management Protocol
• RFC 1542 BOOTP Extensions (VLAN 1 only)(SNMP)
• IGMPv2/IGMPv3• RFC 2474 DiffServ precedence, with 2/4/8 queues per port • IGMP/MLD Snooping • RFC 2475 DiffServ Architecture • RFC 8201 Path MTU Discovery for IPv6 • RFC 2597 DiffServ Assured Forwarding (AF) • RFC 2460 IPv6 Specification • RFC 2598 DiffServ Expedited Forwarding (EF) • RFC 2925 Remote Operations MIB (Ping only) • IEEE 802.1X Port Based Network Access Control • RFC 3315 DHCPv6 (client only) • RF

* 規格以原廠最新 Datasheet 為準。

下載完整PDF規格書

外形尺寸

DS-6000SERIES 外形尺寸圖 (H) 4.39 cm x (H) 4.39 cm (H) 4.39 cm (W) 44.25 cm x (W) 44.2 cm (W) 44.2 cm (D) 32.42 cm (D) 30.48 cm (D) 24.74 cm (1.7

(H) 4.39 cm x (H) 4.39 cm (H) 4.39 cm (W) 44.25 cm x (W) 44.2 cm (W) 44.2 cm (D) 32.42 cm (D) 30.48 cm (D) 24.74 cm (1.7

網絡 WiFi安裝工程服務

HKEZIT 專營裝WIFI、裝ROUTER、裝FIREWALL工程,DS-6000SERIES 由我們供貨、安裝、調試到使用教學一站式完成。無論裝WIFI、裝ROUTER或裝FIREWALL,均由自家工程團隊上門施工,品質有保證。

裝WIFI裝ROUTER裝FIREWALL

網絡 WiFi適合邊類專業客戶

DS-6000SERIES aruba HPE Aruba Networking亦適合以下專業服務機構使用,保安同合規要求同一般商鋪唔一樣,歡迎查詢度身方案。

建築工程顧問公司

圖則模型檔案室保密,配合工地現場監控延伸管理,項目資料防外洩。

WhatsApp 查詢 →

律師事務所

客戶機密文件與會議記錄保安需求高,門禁分級、CCTV存證、通話錄音缺一不可。

WhatsApp 查詢 →

企業秘書/稅務顧問公司

大量客戶公司機密檔案室保安,稅季外勤同事出入記錄管理清晰。

WhatsApp 查詢 →

保險經紀行

客戶會面室簽單過程存證,減少銷售爭議,配合保監局合規要求。

WhatsApp 查詢 →

信託公司/家族辦公室

私人會議室同資料保存區極高保密規格,保障客戶身份同資產私隱。

WhatsApp 查詢 →

知識產權/專利代理

未公開專利同商業機密文件保安要求極高,防止資料外洩爭議。

WhatsApp 查詢 →

常見問題

DS-6000SERIES 香港哪裡有代理?

HKEZIT 提供原廠行貨連保養,DS-6000SERIES 原廠行貨連保養,提供上門安裝、佈線及網絡設定一站式服務,全港 32 區均有服務。

此設備適合什麼工程場景?

詳細規格請參閱上方規格表;我們會按現場點位數量、距離及功率需求設計網絡架構,並提供整體方案報價。

安裝後有問題如何跟進?

原廠行貨保養,工程另設保養期;網絡設備我們會預先設定好即插即用,日後有問題可遠程協助或上門檢查。

DS-6000SERIES 定 DS-AS100SENSOR 邊個好?

兩者屬同系列產品,實際應該邊個型號更適合,需視乎現場環境同需求而定。歡迎直接聯絡我們免費現場評估,由工程師建議最合適方案。

DS-6000SERIES 保養、維修邊度做?

HKEZIT 提供 DS-6000SERIES 原廠行貨連保養,安裝後如有故障可直接聯絡我們安排上門維修,毋須自行聯絡原廠。詳情請參閱網絡 WiFi安裝工程頁面或聯絡我們查詢保養範圍。

香港安裝服務地區

HKEZIT 於全港各區提供 DS-6000SERIES aruba HPE Aruba Networking供貨連專業安裝服務(裝WIFI、裝ROUTER、裝FIREWALL),熱門地區包括:上水網絡佈線 WiFi 工程中環網絡佈線 WiFi 工程九龍城網絡佈線 WiFi 工程九龍灣網絡佈線 WiFi 工程佐敦網絡佈線 WiFi 工程元朗網絡佈線 WiFi 工程北角網絡佈線 WiFi 工程土瓜灣網絡佈線 WiFi 工程。港島、九龍、新界全港 32 區均有上門安裝,歡迎聯絡我們查詢 DS-6000SERIES 香港價格連安裝報價。

網絡 WiFi適用場景

DS-6000SERIES aruba HPE Aruba Networking適合多種場景使用,以下為部分常見安裝場景,歡迎查詢是否適合您的現場環境。

查看更多網絡 WiFi適用場景,請參閱 網絡 WiFi安裝工程

相關產品

如需整套網絡 WiFi方案,請參閱 網絡 WiFi安裝工程

查詢 DS-6000SERIES 連安裝價格

免費上門評估,即日報價,原廠行貨保養

立即查詢