| • | Optional modem. • Remote site upload/download capability (with DACT-UD). |
|---|
| FEATURES | • 99 software zones. |
|---|
| SLC Loop: | User Interface: detectors and 159 monitor, control, or relay modules), able monitor modules, ACS Series annunciators or LCD- including the new addressable dual-monitor module, heat 80F remote annunciator. detectors, and duct detector. • EIA-232 printer/PC interface (variable baud rate) on main (3.31 mm²). Requires twisted, shielded wire (3,000 ft./914.4 • Integral 80-character LCD display with bac |
|---|
| Notification Appliance Circuits (NACs): | • History file with 1,000-event capacity. output control modules (CMF-300 or CMF-300-6). • EIA-485 supporting up to 32 LCD-80F annunciators. main circuit board NACs with two-stage capability. • Automatic device type-code verification. printout. |
|---|
| Advanced Fire Technology: | • Point trouble identification. |
|---|
| • Automatic drift compensation. | • Waterflow (nonsilenceable) selection per monitor point. |
|---|
| Programming and Software: | • System alarm verification selection per detector point. point (NFPA 72 compliant). or PC via PK-Plus Windows® utility. DF-52395:A • 11/26/07 — Page 1 of 6 Distance in |
|---|
| Wire Requirements | Typical Wire Size Feet (m) 10,000 feet 12 AWG (3.31 mm²): Belden 9583, Genesis (3,048 m) 4410, Signal 98230, WPW D999. 8,000 feet 14 AWG (2.08 mm²): Belden 9581, Genesis (2,438 m) 4408, Signal 98430, WPW D995. 4,875 feet 16 AWG (1.31 mm²): Belden 9575, Genesis (1,486 m) 4406 and 4606, Signal 98630, WPW D991. 3,225 feet 18 AWG (0.821 mm²): Belden 9574, Genesis 52395d1.wmf (983 m) 4402 and 4602, Sig |
|---|
| Untwisted, unshielded | 12 – 18 AWG (3.31 – 0.821 mm²). (915 m) box transmitter). |
|---|
| Controls and Indicators | Specifications |
|---|
| LED INDICATORS | AC Power – TB1: 120 VAC, 60 Hz, 3.0 A. Wire size: minimum 14 AWG (2.08 mm²) with 600 V insulation. 1 AC POWER (green) Battery (lead acid only) – TB2: Maximum charging circuit: 2 FIRE ALARM (red) Normal flat charge 27.6 VDC @ 1.0 A. Maximum battery charger capacity: 25 AH. MS-9600 cabinet holds maximum of 3 SUPERVISORY (yellow) two 18 AH batteries. For 25 – 120 AH batteries, use the CHG- 4 ALARM SI |
|---|
| Field-Programming Features | Form-C relays. Four-Wire Resettable Smoke Detector Power (24 VDC nominal) – TB3, Terminals 1(+) & 2(–): Maximum ripple volt- age: 10 mVrms. Up to 3.0 A for powering four-wire smoke detectors. Power-limited circuit. Refer to Fire•Lite Device Com- patibility Document for listed compatible devices. Nonresettable Power #1 (24 VDC Nominal) –TB3, Termi- nals 3 (+) & 4 (–): Maximum ripple voltage: 10 mVr |
|---|
| ual. | (Receive), 3 (DTR), 4 (Ground). (2.74 cm) deep. Backbox: 18.50" (47.0 cm) high x 15.50" |
|---|
| Maintenance Alert | Product Line Information DACT-UD: Optional modem for remote site upload/download and/or remote monitoring. ACM-8RF: Optional plug-in relay module provides 8 Form-C |
|---|
| ble. | dows®-based PC computer (cable not included). SLC-2: Optional expander module, enables second SLC loop. DF-52395:A • 11/26/07 — Page 3 of 6 |
|---|
| MS-9600 cabinet. | ditions (required for Style 7 operation). |
|---|
| DP-9600: Dress panel for MS-9600. | SMB500: Used to mount all modules except the MMF-301 and |
|---|
| FC-TR: Trim Ring for semi-flush mounting. | M301. |
|---|
| ments. | MMF-302-6: Six-zone interface module. Mount one or two ules on a CHS-6 chassis in a BB-6F. modules on a CHS-6 chassis in a BB-6F. |
|---|
| greater than 25 AH batteries. | two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F. NOTES: 1) Compatible with legacy Fire•Lite 300 Series |
|---|
| cable. | ous 300 Series devices: CP300/CP350, SD300(T)/SD350(T), D350(R)P, M300, M301, M302, C304, and BG-10LX. 2) “A” suffix should be included only when ordering ULC listed units (e.g., SD355A, MMF-300A). 3) For more information on Com- |
|---|
| Compatible Addressable Devices | patible Addressable Devices for use with the MS-9600, see CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), |
|---|
| with thermal sensor. | 300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF- 52356), SD355/SD355T (DF-52384). Compatible Annunciators modules and detectors. For more information, refer to data LDM Graphic Series: Lamp Driver Module series for use with playing English-language text. Up to 32 LCD-80F annunciators |
|---|
| provides two Style B (Class B) only IDCs. | face on the MS-9600 motherboard. For more information, |
|---|
| smoke detectors. | 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH(non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful |
|---|
| to power notification appliances. | a normal room temperature of 15 – 27°C/60 – 80°F. Supervisory). 4XTMF). (requires 4XTMF). and Sprinkler Supervised). • UL: S624 • ULC CS68 (except DACT-UD) • FM approved • CSFM 7165-0075:191 • MEA 72-01-E/341-03-E DF-52395:A • 11/26/07 — Page 5 of 6 Windows® is a registered trademark of Microsoft Corporation. ©2007 by Honeywell International Inc. All rights reserved. Unauthorized use of this docum |
|---|