| ALL DIMENSIONS IN INCHES AND MILLIMETERS | Certification: UL listed for USA and Canada ULC listed for Canada Class 1 Div 1 Groups C & D and Class 1, Zone 1. 43/4" / 121mm 53/16" / 132mm UL Listing No. E186629 4 /8" / 105mm 37/16" / 87mm ULC Listing No. E320282 17/16" CSA Certification: 37mm I.S. Version – Class 1, Groups A-D. Exd Class I, Div 2 1/2 Group D. Enclosure type 4, Cert. No. 79120. ATEX approved: EN50014, EN50018. Cert. No. Basee |
|---|
| Voltage: | 24V a.c./d.c. |
|---|
| Rating: | 2 amp. (30mA max. with LED) |
|---|
| Switches: | 2 pole c/o, wired to terminals. |
|---|
| Terminals: | Will accept up to 14AWG cable. |
|---|
| Entries: | Up to 4 x 1/2" or 3/4" NPT /8" / 9.5mm DIA. |
|---|
| Optional | A red high intensity LED can be fitted |
|---|
| 指示燈 | for alarm indication. |
|---|
| 材質 | LM 25 TF Marine Grade Alloy. |
|---|
| 重量 | 5.5 lb/2.5kg (approx.). |
|---|
| Finish: | Epoxy paint finish as standard or to customer's specification. |
|---|
| Certified | UL/ULC –40°F to +158°F (–40°C to +70°C). |
|---|
| Temperature: | – 4°F to +131°F (–20°C to +55°C) LED version only. CSA: –58°F to +131°F (–50°C to +55°C) (Exd). –58°F to +104°F (–50°C to +40°C) (Exi). |
|---|
| Ordering Requirements | Ingress NEMA 4x and 6, IP66 & 67. |
|---|
| 防護等級 | SM87 PB IP68 (40m for 8 hours). |
|---|
| Duty | Tag |
|---|
| Unit Type | Model Material Certification Entries Label Label Features Finish |
|---|
| SM87 | PBL A |
|---|
| Certification | Code Entries Code Features Code |
|---|
| To order ATEX approved | UL Listed UL 1 |
|---|
| /2" NPT | 3 Not required N |
|---|
| version see European | ULC Listed UC 3 |
|---|
| /4" NPT | 4 LED A |
|---|
| data sheet. | CSA-Exd* DC Please specify Series Resistor †G |
|---|
| CSA-Exi* | IC Top *T EOL Resistor †H |
|---|
| *Other SM87 CSA Certified | Bottom *B Diode *D |
|---|
| models are available. | RHS *R Addressable Module ††M |
|---|
| See European data sheet for | LHS *L * Specify values. |
|---|
| details. | *prefix position with size code † d.c. and I.S. units only. |
|---|
| i.e. 3T 3B = 1/2" NPT Top | †† Not available on ULC |
|---|
| and Bottom | version † Max. 3 entries on ULC |
|---|
| versions. | Tag Label Code |
|---|
| Required | Y |
|---|
| Label | Code Not Required N |
|---|
| Push Button | 2 |
|---|
| Finish | Code |
|---|
| Fire-Push Button | 3 |
|---|
| ESDO-Abandon | 4 Red R |
|---|
| FIRE/FEU | 5** Blue B |
|---|
| NOTE: The units can be internally wired | Other O* Yellow Y |
|---|
| to suit customers specifications. | *Please specify Yellow/ |
|---|
| Please discuss your requirements | ** This option must be used Black Stripes X |
|---|
| with us. | when ordering a red callpoint Special Finish S for ULC Fire Alarm applications. All the above specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 05/09 |
|---|