  • FMM-1 Monitor Module:devices. Its compact design allows the FMM-101 to be mounted
  • identifies this device as a monitor:FlashScan loops; 01 – 99 on CLIP loops.
  • module to the control panel.:• LED flashes green during normal
  • • Powered directly by two-wire SLC loop.:operation (programmable option) and
  • No additional power required.:latches on steady red to indicate alarm • High noise (EMF/RF
HKEZIT 提供原廠行貨保養。硬件連專業安裝、設定及使用教學一站式報價,無需自行研究安裝與設定。我們同時承接裝ALARM、裝防盜、裝警鐘工程,硬件與工程同一團隊負責。
查詢價格連安裝
HCE-DOC-02-040 honeywell 1, FRM-1 Series 產品圖片

詳細規格

FMM-1 Monitor Moduledevices. Its compact design allows the FMM-101 to be mounted in a single-gang box behind the device it monitors. FZM-1 Interface Module is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a circuit. FCM-1 Addressable Control Module provides Notifier intelligent fire alarm control panels a circuit for Notification Appliances (horns, strobes, spea
identifies this device as a monitorFlashScan loops; 01 – 99 on CLIP loops.
module to the control panel.• LED flashes green during normal
• Powered directly by two-wire SLC loop.operation (programmable option) and
No additional power required.latches on steady red to indicate alarm • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. FMM-1 Monitor Module The FMM-1 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circ
FMM-1 ApplicationsFMM-1 Operation Use to monitor a zone of four-wire Each FMM-1 uses one of the available smoke detectors, manual normally module addresses on an SLC loop. It
opendry-contact alarm activation responds to regular polls from the control devices. May also be used to monitor panel and reports its type and the status (open/normal/short) of its Initiating Device
normally-opensupervisory devices Circuit (IDC). A flashing LED indicates that with special supervisory indication at the module is in communication with the the control panel. Monitored circuit control panel. The LED latches steady on may be wired as an typical 2-wire alarm (subject to current limitations on
initiatingcircuit configuration or the loop). 4-wire fault tolerant initiating circuit
configuration.A 47K Ohm End-of- Line Resistor (provided) terminates the circuit. No resistor is required for supervision of the circuit. FMM-1 Specifications
NOMRAL OPERATING15- 32 VDC VOLTAGE
MAXIMUM CURRENT DRAW5.0 mA (LED on)
AVERAGE OPERATING375 μA (LED flashing), 1 communication every 5 seconds,
CURRENT47k EOL
MAXIMUM IDC WIRING1500 Ohms RESISTANCE
MAXIMUM IDC VOLTAGE11 Volts
EOL RESISTANCE47k Ohms
TEMPERATURE RANGE0°C to 49°C
HUMIDITY RANGE10% to 93% non-condensing FMM-101 Mini Monitor Module The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting.The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides
FMM-101 ApplicationsFMM-101 Operation Use to monitor a single device or a Each FMM-101 uses one of the available zone of four-wire smoke detectors, module addresses on an SLC loop. It
manualfire alarm pull stations, responds to regular polls from the control waterflow devices, or other normally- panel and reports its type and the status (open/normal/short) of its Initiating Device open dry-contact devices. May also Circuit (IDC). be used to monitor normally-open
supervisorydevices with special supervisory indication at the control
panel.Monitored circuit/device is wired as an 2-wire initiating device circuit configuration. A 47k Ohm End- of-Line Resistor (provided) terminates the circuit. FMM-101 Specifications
尺寸3.302 cm high x 6.985 cm wide x 1.651 cm deep. FZM-1 Interface Module The FZM-1 Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one
FZM-1 ApplicationsFZM-1 Operation Use the FZM-1 to monitor a zone of two- Each FZM-1 uses one of the available wire smoke detectors. The monitored module addresses on an SLC loop. It circuit may be wired as an typical responds to regular polls from the control 2-wire initiating circuit configuration panel and reports its type and the status (open/normal/short) of its Initiating Device or 4-wire fault tolerant initi
MAXIMUM IFC WIRING25 Ohms RESISTNACE
Intelligent/ Addressable DevicesCURRENT seconds, 3.9k EOL
• Built-in type identification• High noise immunity (EMF/RFI).
automatically identifies these devices• The FCM-1 may be used to switch
to the control panel.24-volt NAC power, audio (up to 70.7
• Internal circuitry and relay poweredVrms).
directly by two-wire SLC loop. The• Wide viewing angle of LED. FCM-1 module requires power (for • SEMS screws with clamping plates for horns, strobes, etc.), or audio (for wiring ease. speakers). • Direct-dial entry of address 01– 159 for • Integral LED “blinks” green each time FlashScan loops, 01 – 99 for CLIP mode a communication is received from the loops. control panel and turns on in steady • Speaker, and audible/visual red w
FCM-1, FRM-1 ApplicationsFCM-1, FRM-1 Construction
FCM-1 is used to switch 24 VDC• The face plate is made of off-white
audible/visual power, high-levelheat-resistant plastic.
audio (speakers).FRM-1 may be • Controls include two rotary switches
programmed to operate dry contactsfor direct-dial entry of address (01-
for applications such as door holders159). or Air Handling Unit shutdown, and to • FCM-1 is configured for a single 2-wire
reset four-wire smoke detector power.or 4-wire fault tolerant Notification Appliance Circuit. • FRM-1 provides two Form-C dry contacts that switch together. FCM-1, FRM-1 Operation Each FCM-1 or FRM-1 uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit
MAXIMUM NAC LINE LOSS4 VDC
EXTERNAL SUPPLY VOLTAGEMaximum (NAC): Regulated 24 VDC; (BETWEEN TERMINAL T10
AND T11)Maximum (Speakers): 70.7 V RMS, 50W. 1.7 mA maximum using 24 VDC DRAIN ON EXTERNAL SUPPLY supply; 2.2 mA Maximum using 80 VRMS supply For class B wiring system, the current rating is 3A; For MAX NAC CURRENT RATINGS: class A wiring system, the current rating is 2A.
RATINGVOLTAGE DESCRIPTION APPLICATION 30 VDC Resistive Non-Coded 30 VDC Resistive Coded 110 VDC Resistive Non-Coded 0.9A 125 VDC Resistive Non-Coded 0.9A 30 VDC Inductive Coded 0.5A (L/R= 5ms) 30 VDC Inductive Coded (L/R= 2ms) 125 VAC Inductive Non-Coded 0.3A (PF= 0.35) 25 VAC Inductive Non-Coded 1.5A (PF= 0.35) 70.7 VAC Inductive Non-Coded 0.7A (PF= 0.35) 25 VAC Inductive Non-Coded (PF= 0.35) Note: Max
FMM-1-AUSMonitor module
FMM-101-AUSMonitor module, miniature
FZM-1-AUSMonitor module, two-wire detectors
FCM-1-AUSIntelligent Addressable Control Module
FRM-1-AUSIntelligent Addressable Relay Module
SMB500Optional surface-mount backbox. NOTE: For installation instructions, see the following documents:
FCM-1 - Installation Manual I56_3500_003 • FRM -1 - Installation Manual I56-3502-002 • FMM-1 - Installation Manual I56-3506-001 • FMM101 - Installation Manual I56-3508-001 • FZM-1 - Installation Manual I56-3504-002 www.notifier.com.au ISO9001 FS 520324
© 2021 Honeywell International Inc.DOC-02-040 / 10/21 | Rev B ENGINEERING & MANUFACTURING QUALITY SYSTEMS

* 規格以原廠最新 Datasheet 為準。

下載完整PDF規格書

防盜報警安裝工程服務

HKEZIT 專營裝ALARM、裝防盜、裝警鐘工程,HCE-DOC-02-040 由我們供貨、安裝、調試到使用教學一站式完成。無論裝ALARM、裝防盜或裝警鐘,均由自家工程團隊上門施工,品質有保證。

裝ALARM裝防盜裝警鐘

防盜報警適合邊類專業客戶

HCE-DOC-02-040 honeywell 1, FRM-1 Series亦適合以下專業服務機構使用,保安同合規要求同一般商鋪唔一樣,歡迎查詢度身方案。

知識產權/專利代理

未公開專利同商業機密文件保安要求極高,防止資料外洩爭議。

WhatsApp 查詢 →

企業秘書/稅務顧問公司

大量客戶公司機密檔案室保安,稅季外勤同事出入記錄管理清晰。

WhatsApp 查詢 →

珠寶鑑定/拍賣行

高值品鑑定過程近攝存證,配合保險公司要求,防止調換或盜取。

WhatsApp 查詢 →

私人銀行/財富管理

貴賓客戶室高保安等級佈點,配合監管合規存證,出入口身份記錄嚴謹。

WhatsApp 查詢 →

律師事務所

客戶機密文件與會議記錄保安需求高,門禁分級、CCTV存證、通話錄音缺一不可。

WhatsApp 查詢 →

信託公司/家族辦公室

私人會議室同資料保存區極高保密規格,保障客戶身份同資產私隱。

WhatsApp 查詢 →

常見問題

HCE-DOC-02-040 香港哪裡有代理?

HKEZIT 提供原廠行貨連保養,HCE-DOC-02-040 原廠行貨連保養,提供上門評估、安裝、防區設定及使用教學一站式服務,全港 32 區均有服務。

此設備適合什麼場景?

詳細規格請參閱上方規格表;我們會按現場環境(商舖、辦公室、倉庫、住宅)設計防區及感應器布局,並提供整體方案報價。

觸發警報後如何通知?

可按需求配置本地警號、手機 App 推送或短訊通知;亦可與 CCTV 聯動,觸發時自動錄影存證。

HCE-DOC-02-040 定 MODEL-811FM-TWO-WIRE-GAGE-ABSOLUTE-PRESS 邊個好?

兩者屬同系列產品,實際應該邊個型號更適合,需視乎現場環境同需求而定。歡迎直接聯絡我們免費現場評估,由工程師建議最合適方案。

HCE-DOC-02-040 保養、維修邊度做?

HKEZIT 提供 HCE-DOC-02-040 原廠行貨連保養,安裝後如有故障可直接聯絡我們安排上門維修,毋須自行聯絡原廠。詳情請參閱防盜報警安裝工程頁面或聯絡我們查詢保養範圍。

香港安裝服務地區

HKEZIT 於全港各區提供 HCE-DOC-02-040 honeywell 1, FRM-1 Series供貨連專業安裝服務(裝ALARM、裝防盜、裝警鐘),熱門地區包括:沙田防盜報警系統安裝油麻地防盜報警系統安裝深水埗防盜報警系統安裝灣仔防盜報警系統安裝筲箕灣防盜報警系統安裝紅磡防盜報警系統安裝荃灣防盜報警系統安裝葵涌防盜報警系統安裝。港島、九龍、新界全港 32 區均有上門安裝,歡迎聯絡我們查詢 HCE-DOC-02-040 香港價格連安裝報價。

防盜報警適用場景

HCE-DOC-02-040 honeywell 1, FRM-1 Series適合多種場景使用,以下為部分常見安裝場景,歡迎查詢是否適合您的現場環境。

查看更多防盜報警適用場景,請參閱 防盜報警安裝工程

相關產品

如需整套防盜報警方案,請參閱 防盜報警安裝工程

查詢 HCE-DOC-02-040 連安裝價格

免費上門評估,即日報價,原廠行貨保養

立即查詢