| FMM-1 Monitor Module | devices. Its compact design allows the FMM-101 to be mounted in a single-gang box behind the device it monitors. FZM-1 Interface Module is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a circuit. FCM-1 Addressable Control Module provides Notifier intelligent fire alarm control panels a circuit for Notification Appliances (horns, strobes, spea |
|---|
| identifies this device as a monitor | FlashScan loops; 01 – 99 on CLIP loops. |
|---|
| module to the control panel. | • LED flashes green during normal |
|---|
| • Powered directly by two-wire SLC loop. | operation (programmable option) and |
|---|
| No additional power required. | latches on steady red to indicate alarm • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. FMM-1 Monitor Module The FMM-1 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circ |
|---|
| FMM-1 Applications | FMM-1 Operation Use to monitor a zone of four-wire Each FMM-1 uses one of the available smoke detectors, manual normally module addresses on an SLC loop. It |
|---|
| open | dry-contact alarm activation responds to regular polls from the control devices. May also be used to monitor panel and reports its type and the status (open/normal/short) of its Initiating Device |
|---|
| normally-open | supervisory devices Circuit (IDC). A flashing LED indicates that with special supervisory indication at the module is in communication with the the control panel. Monitored circuit control panel. The LED latches steady on may be wired as an typical 2-wire alarm (subject to current limitations on |
|---|
| initiating | circuit configuration or the loop). 4-wire fault tolerant initiating circuit |
|---|
| configuration. | A 47K Ohm End-of- Line Resistor (provided) terminates the circuit. No resistor is required for supervision of the circuit. FMM-1 Specifications |
|---|
| NOMRAL OPERATING | 15- 32 VDC VOLTAGE |
|---|
| MAXIMUM CURRENT DRAW | 5.0 mA (LED on) |
|---|
| AVERAGE OPERATING | 375 μA (LED flashing), 1 communication every 5 seconds, |
|---|
| CURRENT | 47k EOL |
|---|
| MAXIMUM IDC WIRING | 1500 Ohms RESISTANCE |
|---|
| MAXIMUM IDC VOLTAGE | 11 Volts |
|---|
| EOL RESISTANCE | 47k Ohms |
|---|
| TEMPERATURE RANGE | 0°C to 49°C |
|---|
| HUMIDITY RANGE | 10% to 93% non-condensing FMM-101 Mini Monitor Module The FMM-101 Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting.The FMM-101 is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides |
|---|
| FMM-101 Applications | FMM-101 Operation Use to monitor a single device or a Each FMM-101 uses one of the available zone of four-wire smoke detectors, module addresses on an SLC loop. It |
|---|
| manual | fire alarm pull stations, responds to regular polls from the control waterflow devices, or other normally- panel and reports its type and the status (open/normal/short) of its Initiating Device open dry-contact devices. May also Circuit (IDC). be used to monitor normally-open |
|---|
| supervisory | devices with special supervisory indication at the control |
|---|
| panel. | Monitored circuit/device is wired as an 2-wire initiating device circuit configuration. A 47k Ohm End- of-Line Resistor (provided) terminates the circuit. FMM-101 Specifications |
|---|
| 尺寸 | 3.302 cm high x 6.985 cm wide x 1.651 cm deep. FZM-1 Interface Module The FZM-1 Interface Module is intended for use in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one |
|---|
| FZM-1 Applications | FZM-1 Operation Use the FZM-1 to monitor a zone of two- Each FZM-1 uses one of the available wire smoke detectors. The monitored module addresses on an SLC loop. It circuit may be wired as an typical responds to regular polls from the control 2-wire initiating circuit configuration panel and reports its type and the status (open/normal/short) of its Initiating Device or 4-wire fault tolerant initi |
|---|
| MAXIMUM IFC WIRING | 25 Ohms RESISTNACE |
|---|
| Intelligent/ Addressable Devices | CURRENT seconds, 3.9k EOL |
|---|
| • Built-in type identification | • High noise immunity (EMF/RFI). |
|---|
| automatically identifies these devices | • The FCM-1 may be used to switch |
|---|
| to the control panel. | 24-volt NAC power, audio (up to 70.7 |
|---|
| • Internal circuitry and relay powered | Vrms). |
|---|
| directly by two-wire SLC loop. The | • Wide viewing angle of LED. FCM-1 module requires power (for • SEMS screws with clamping plates for horns, strobes, etc.), or audio (for wiring ease. speakers). • Direct-dial entry of address 01– 159 for • Integral LED “blinks” green each time FlashScan loops, 01 – 99 for CLIP mode a communication is received from the loops. control panel and turns on in steady • Speaker, and audible/visual red w |
|---|
| FCM-1, FRM-1 Applications | FCM-1, FRM-1 Construction |
|---|
| FCM-1 is used to switch 24 VDC | • The face plate is made of off-white |
|---|
| audible/visual power, high-level | heat-resistant plastic. |
|---|
| audio (speakers). | FRM-1 may be • Controls include two rotary switches |
|---|
| programmed to operate dry contacts | for direct-dial entry of address (01- |
|---|
| for applications such as door holders | 159). or Air Handling Unit shutdown, and to • FCM-1 is configured for a single 2-wire |
|---|
| reset four-wire smoke detector power. | or 4-wire fault tolerant Notification Appliance Circuit. • FRM-1 provides two Form-C dry contacts that switch together. FCM-1, FRM-1 Operation Each FCM-1 or FRM-1 uses one of 159 possible module addresses on a SLC loop (99 on CLIP loops). It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit |
|---|
| MAXIMUM NAC LINE LOSS | 4 VDC |
|---|
| EXTERNAL SUPPLY VOLTAGE | Maximum (NAC): Regulated 24 VDC; (BETWEEN TERMINAL T10 |
|---|
| AND T11) | Maximum (Speakers): 70.7 V RMS, 50W. 1.7 mA maximum using 24 VDC DRAIN ON EXTERNAL SUPPLY supply; 2.2 mA Maximum using 80 VRMS supply For class B wiring system, the current rating is 3A; For MAX NAC CURRENT RATINGS: class A wiring system, the current rating is 2A. |
|---|
| RATING | VOLTAGE DESCRIPTION APPLICATION 30 VDC Resistive Non-Coded 30 VDC Resistive Coded 110 VDC Resistive Non-Coded 0.9A 125 VDC Resistive Non-Coded 0.9A 30 VDC Inductive Coded 0.5A (L/R= 5ms) 30 VDC Inductive Coded (L/R= 2ms) 125 VAC Inductive Non-Coded 0.3A (PF= 0.35) 25 VAC Inductive Non-Coded 1.5A (PF= 0.35) 70.7 VAC Inductive Non-Coded 0.7A (PF= 0.35) 25 VAC Inductive Non-Coded (PF= 0.35) Note: Max |
|---|
| FMM-1-AUS | Monitor module |
|---|
| FMM-101-AUS | Monitor module, miniature |
|---|
| FZM-1-AUS | Monitor module, two-wire detectors |
|---|
| FCM-1-AUS | Intelligent Addressable Control Module |
|---|
| FRM-1-AUS | Intelligent Addressable Relay Module |
|---|
| SMB500 | Optional surface-mount backbox. NOTE: For installation instructions, see the following documents: |
|---|
| • | FCM-1 - Installation Manual I56_3500_003 • FRM -1 - Installation Manual I56-3502-002 • FMM-1 - Installation Manual I56-3506-001 • FMM101 - Installation Manual I56-3508-001 • FZM-1 - Installation Manual I56-3504-002 www.notifier.com.au ISO9001 FS 520324 |
|---|
| © 2021 Honeywell International Inc. | DOC-02-040 / 10/21 | Rev B ENGINEERING & MANUFACTURING QUALITY SYSTEMS |
|---|