| Module Specifications | PRO4200 Series Single Reader Module PRO4200 Series Dual Reader Module (PRO42R1) (PRO42R2/PRO42R2B) |
|---|
| Port | Reader port 12/24VDC @ 500mA, OSDP; Wiegand; 2 Reader port 12/24VDC @ 300mA, OSDP; Wiegand; |
|---|
| Date / Clock | Date / Clock |
|---|
| Keypad | Keypad multiplexed with card data Keypad multiplexed with card data |
|---|
| Wire Support | Two-wire or one-wire bi-color LED support Two-wire or one-wire bi-color LED support |
|---|
| Buzzer Support | Buzzer support only with one-wire LED control Buzzer support only with one-wire LED control |
|---|
| Alarm Inputs | 2 supervised, general purpose alarm inputs with 8 supervised, general purpose alarm inputs with program- |
|---|
| programmable circuit type | mable circuit type (only 6 supervised inputs available when using PRO22ENC1, PRO22ENC2 enclosures) |
|---|
| Output Relays (Door Strike(s)) | 1 output relay, form C, 5A 40 VDC 2 output relay, form C, 2A 30 VDC |
|---|
| Output Relays | 1 general purpose output relay, form C, 5A 30 VDC 2 general purpose output relay, form C, 5A 30 VDC |
|---|
| Mounting | Designed to be tile-mounted N/A Alarm Input Properties |
|---|
| Inputs | Inputs may be assigned to door related functions Inputs may be assigned to door related functions |
|---|
| or general purpose I/O | or general purpose I/O |
|---|
| Circuit Type | Circuit type - normally open, normally closed, Circuit type - normally open, normally closed, non-supervised, supervised (with standard 1K or non-supervised, supervised (with standard 1K or |
|---|
| custom end-of-line resistance 200-10K Ω) | custom end-of-line resistance 200-10K Ω) Output Control Properties |
|---|
| Outputs | Outputs may be assigned to door related functions or Outputs may be assigned to door related functions or |
|---|
| general purpose I/O | general purpose I/O |
|---|
| Relay Rating | The relay(s) are rated to handle the inductive loads of door The relay(s) are rated to handle the inductive loads of door |
|---|
| locking devices | locking devices |
|---|
| S-4 suppressor cable to the door opener | S-4 suppressor cable to the door opener |
|---|
| Configurable | Configurable as standard (energize to activate) or fail-safe Configurable as standard (energize to activate) or fail-safe (de-energize to activate) (de-energize to activate) |
|---|
| Pulse Time | 1-42,400 seconds, 1-255 for door relays 1-42,400 seconds, 1-255 for door relays |
|---|
| RS485 Port | RS485 port, 4,000 ft (1,250m) total bus length RS485 port, 4,000 ft (1,250m) total bus length |
|---|
| Standard Speed | 38.4 Kbps 38.4 Kbps |
|---|
| Output | All 16-relay outputs in the tile-mount configuration Both relay outputs are available for general purpose I/O 1 rack mount) are available for general purpose I/O |
|---|
| Dry Circuit Logic | The 5A relays are rated to handle dry circuit logic (Resistive) Both relay outputs are rated to handle dry circuit logic (Resistive) |
|---|
| Measurements | RS485 port, 4,000 ft (1,250m) total bus length per port RS485 port, 4,000 ft (1,250m) total bus length per port |
|---|
| Speed | 38.4 Kbps 38.4 Kbps Elements RS485 Max 32 (includes PRO42IC onboard I/O) PRO42IC |
|---|
| Door 1 and 2 | Door 1 and 2 |
|---|
| PRO42R2 | PRO42IN PRO42OUT |
|---|
| PRO22ENC1 | PRO22ENC3 |
|---|
| Module | Readers Inputs Outputs Inputs Outputs |
|---|
| PRO42R1 | 2 OSDP | 1 Wiegand N/A N/A 2 2 |
|---|
| PRO42R2/R2B | 4 OSDP | 2 Wiegand 6 4 10** 6 |
|---|
| PRO42OUT | 0 0 12 2* 16 |
|---|
| PRO42IN | 0 16 1 18* 2 |
|---|
| Dimensions / Boards | 2.75” H x 4.25” W x 1.0” D 9.0” H x 5.5” W x 1.0” D (70mm x 108mm 25mm) (230mm x 140mm x 25mm) |
|---|
| Dimensions / Enclosures | 13.9” H x 17” W x 9” D 13.9” H x 18.9” W x 9” D 14” H x 16” W x 4” D (353 mm x 432mm x 229 mm) (353 mm x 480 mm x 229 mm) (356 mm x 406 mm x 102 mm) |
|---|
| Temperature | 0°C to 49°C* operational; 0°C to 49°C* operational; 0°C to 49°C* operational; |
|---|
| -55°C to 85°C storage | -55°C to 85°C storage -55°C to 85°C storage |
|---|
| Humidity | 5 to 85% RHNC 5 to 85% RHNC 5 to 85% RHNC Wire Requirements |
|---|
| 供電 | Twisted pair, 18 AWG Twisted pair, 18 AWG Twisted pair, 18 AWG |
|---|
| Ethernet | F(S)TP/CAT7, 300 ft (100m) max F(S)TP/CAT7, 300 ft (100m) max F(S)TP/CAT7, 300 ft (100m) max |
|---|
| RS485 | 22- 24 AWG, 4,000 ft (1,200m) max, 22- 24 AWG, 4,000 ft (1,200m) max, 22- 24 AWG, 4,000 ft (1,200m) max, |
|---|
| two twisted pairs with shield | two twisted pairs with shield two twisted pairs with shield (F(S)TP/CAT7) (F(S)TP/CAT7) (F(S)TP/CAT7) |
|---|
| 警報輸入 | Twisted pair, 30 ohms max Twisted pair, 30 ohms max Twisted pair, 30 ohms max |
|---|
| PRO42IC | PRO42R2/R2B PRO42OUT PRO42IN |
|---|
| PRO4200 Controllers | PRO4200 Expansion Kits |
|---|
| PRO42E1D6 | 6 Door Kit: (2) PRO42R2B, |
|---|
| PRO42R2B | PRO4200 Dual Reader Module (4) S-4, and (1) PRO42E1EN |
|---|
| PRO42E1D10 | 10 Door Kit: (4) PRO42R2B, |
|---|
| PRO-Series Enclosures | Optional Accessories |
|---|
| and battery not included | PRO22ENC2 |
|---|
| PRO22ENC2 | (19" Rack-mount) Capacity: 9 modules. Power PRO42PSU120 Rack-mounted power supply for PRO22ENC1, |
|---|
| supply and battery not included | PRO22ENC2 Requires MPA2BAT7 |
|---|
| PRO22ENC3 | (Tile-mount) Capacity: 2 modules. Power supply |
|---|
| and battery included | MPA2BAT7 Battery, 7AH 12V Network Kits same as last line above |
|---|
| PRO42E1EN | Includes: PRO22ENC1, PRO42IC, PRO42PSU120, MPA2BAT7 and PRO22DCC |
|---|
| PRO42E2EN | Includes: PRO22ENC2, PRO42IC, PRO42PSU120, MPA2BAT7 and PRO22DCC |
|---|