| SIZE | 5.8 x 3.3 x 1.6 in. / 14.8 x 8.5 x 4.0 cm STANDARD MEASURING |
|---|
| 重量 | 14.5 oz. / 411 g (with clip) |
|---|
| GASES | RANGE RESOLUTION |
|---|
| 工作溫度 | -4 to +131° F / -20 to +50° C |
|---|
| OXYGEN (O2) | 0-25% vol. 0.1% vol. |
|---|
| HUMIDITY | 5 - 95% RH (non‑condensing) continuous |
|---|
| COMBUSTIBLE GASES (LEL) | 0-100% LEL 1% LEL |
|---|
| 防護等級 | IP66/68 |
|---|
| COMBUSTIBLE GASES (IR)* | 0-5.00% vol. 0.01% vol. |
|---|
| ALARMS AND TYPE | Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit) |
|---|
| HYDROGEN SULFIDE (H2S) | 0-100 ppm 1 ppm / 0.1 ppm |
|---|
| SELF-TEST | Activated detectors automatically perform one internal diagnostic |
|---|
| CARBON MONOXIDE (CO) | 0-2,000 ppm 1 ppm test every 24 hours (sensors, battery, and circuitry). |
|---|
| CARBON MONOXIDE (LOW H2) | 0-1,000 ppm 1 ppm |
|---|
| TYPICAL BATTERY LIFE | 18 hours (14 hours with PID or IR sensor) @ -4° F / -20° C (CO-H) |
|---|
| PUMP DRAW | Sample from up to 75 ft. / 22.9 m |
|---|
| SULFUR DIOXIDE (SO2) | 0-100 ppm 0.1 ppm |
|---|
| CONNECTED WORKER | • Bluetooth™ Low Energy (BLE) – Ability to connect |
|---|
| HYDROGEN (H2) | 0-2,000 ppm 5 ppm to Honeywell’s Safety Communicator App • Honeywell TouchConnect™ – Easy ability to enter CARBON DIOXIDE (CO2) 0-50,000 ppm 100 ppm Bump or Calibration mode or change Set-Points AMMONIA (NH3) 0-100 ppm 1 ppm |
|---|
| EVENT LOGGING | 30 alarm events and 10 bump events VOLATILE ORGANIC 0-1,000 ppm 1 ppm |
|---|
| DATA LOGGING | 45 days based on 8 hour shifts every 15 seconds logging COMPOUNDS (VOC) ** |
|---|
| USER OPTIONS | • Adjust STEL period (5-15 minutes in 1 minute intervals) CHLORINE (CL2) 0-20 ppm 0.1 ppm |
|---|
| • Calibration span levels | NITROGEN DIOXIDE (NO2) 0-50 ppm 0.1 ppm • Calibration interval |
|---|
| • Bump test interval | HYDROGEN CYANIDE (HCN) 0-100 ppm 0.1 ppm • Select combustible gases measurement: 0-100% LEL NITROGEN MONOXIDE (NO) 0-200 ppm 1 ppm (Lower Explosive Limit) or Methane gas 0-5.0% v/v |
|---|
| • LEL and PID correction factors | * Caution – the LEL IR combustible gas sensor option used in • Calibration due date (1 to 365 days, or set to zero for off) Honeywell BW™ Ultra cannot detect certain combustible gases |
|---|
| • Individual sensor enable/disable | including hydrogen and acetylene. The application should |
|---|
| • Latching alarms | be reviewed to ensure the Honeywell BW™ Ultra can provide |
|---|
| • Stealth mode | adequate detection. For more information, please contact • Languages: English, French, German, Portuguese, Honeywell Analytics (www.honeywellanalytics.com). Spanish, Simplified Chinese and Russian ** Please contact Honeywell Analytics for availability. |
|---|
| CERTIFICATIONS AND | h: Class I, Div 1, Group A, B, C, D |
|---|
| APPROVALS | Class I, Zone 0, Group IIC |
|---|
| ATEX : | II 1G Ex ia IIC T4 Ga INTELLIDOX IECEx : Ex ia IIC T4 Ga DOCKING SYSTEM |
|---|
| X: | European Conformity For additional certifications, please review the manual or consult IntelliDoX combines |
|---|
| Honeywell Analytics. | smart-docking |
|---|
| WARRANTY | Instrument: 3 years modules with Sensors: 3 years (2 years NH3, 1 year PID and Cl2) |
|---|
| Battery: 2 years | our instrument management |
|---|
| WITHOUT NOTICE. | system to provide automated testing and record keeping. |
|---|
| US: ha.us.service@honeywell.com | Datasheet_Honeywell BW Ultra_DS01195-01_US-EN | 04/18 |
|---|
| AP: ha.ap.service@honeywell.com | © 2018 Honeywell International Inc. |
|---|