| Detection method | Infrared beam interruption detection (STANDARD MODEL) AX-100 / 200TF |
|---|
| Maximum detection range | 20m (70ft.) 40m (130ft.) 60m (200ft.) 30m (100ft.) 60m (200ft.) |
|---|
| Maximum arrival range | 200m (700ft.) 400m (1300ft.) 600m (2000ft.) 300m (1000ft.) 600m (2000ft.) |
|---|
| Interruption period | Selectable between 50, 100, 250, and 500m sec. (ENHANCED MODEL) |
|---|
| Selectable beam frequency | 4 channel |
|---|
| 供電 | 10.5 - 28V DC Current consumption (transmitter + receiver) 38mA (max.) 41mA (max.) 45mA (max.) 44mA (max.) 48mA (max.) |
|---|
| Alarm period | 2sec. (±1) nominal |
|---|
| 警報輸出 | N.C. 28V DC, 0.2A (max.) N.C./N.O. 28V DC, 0.2A (max.) |
|---|
| D.Q. output | N.C. 28V DC, 0.2A (max.) |
|---|
| Tamper switch | Opens when cover is removed at 28V DC, 0.2A max. -35°C to +60°C (-31°F to +140°F) Operating temperature Use the optional heating unit (HU-3) in conditions of -25°C (-13°F) or below. |
|---|
| 工作濕度 | 95% max. |
|---|
| Alignment angle | ± 90° Horizontal, ± 5° Vertical |
|---|
| Mounting | Wall and pole mounting |
|---|
| Weight (transmitter + receiver) | 650g (22.9oz.) 700g (24.7oz.) |
|---|
| Housing protection (EN 00529) | IP65 NOTE: These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. These products conform to the EMC Directive 89/336 ECC. |
|---|
| 尺寸 | OPTIONS ■ HU-3 : Heating Unit Heating unit for severe low temperature conditions 24V DC/AC, 420mA max. 36 (1.4) 1 set (2 units) ■ BC-3 : Back Cover Can be used to cover mounting pole. 83.5 (3.3) 170 (6.7) 1 set (2 units) ■ PSC-3 : Pole Side Cover Cover for installing 2 units to 1 pole. 65 (2.6) 69.5 (2.7) 1 set (2 units) Dimensions : mm (inches) OPTEX CO., LTD. (ISO 9001 Certified by LRQA / ISO140 |
|---|
| OPTEX INCORPORATED (USA) | http://www.optexamerica.com |
|---|
| OPTEX (EUROPE) LTD. (UK) | http://www.optexeurope.com "stable detection performance". OPTEX SECURITY SAS (FRANCE) OPTEX KOREA CO., LTD. (KOREA) http://www.optex-security.com http://www.optexkorea.com These features reduce false alarms drastically caused by outdoor severe environmental changes and |
|---|
| OPTEX SECURITY Sp. z o.o. (POLAND) | provide a wide range of applications. “Take Care of the Environment” This catalogue uses recycled paper No. 75107-00-909-0612 AX-70 / 130 / 200TN (STANDARD MODEL) |
|---|
| The best short range photoelectric | AX-100 / 200TF (ENHANCED MODEL) □ IP65 structure with high sealing rubber packing □ Anti-frost hood cover |
|---|
| detector from OPTEX | Rubber packing is used for all conceivable points where water or dust may penetrate, such as wiring holes, wire ports and the outer A hood is installed to prevent frost forming on lower beams. It also makes the maintenance easy because the surface of the cover is flat. □ Lightning protection |
|---|
| chassis. Prevention from dust, bugs | An improved Electro-Magnetic Interference surge absorber and high |
|---|
| and water delivers performance with | surge resistive relay has been installed to protect from lightning surges |
|---|
| higher reliability against false alarms | and maintain stable operation. and breakdowns. |
|---|
| Rubber | Lightning Protection Level packing IP65 Will remain stable against over |
|---|
| Waterproof. | Wiring Conventional 14kV of lightning surge. |
|---|
| Protected against water jets from | hole Detector any direction Dust-tight. AX Series No ingress of dust. 0 2 4 6 8 10 12 14 |
|---|
| International Protection Code. | Lightning Surge Voltage Level (kV) It shows the degress of protection provided by enclosures. □ Easy angle adjustment It allows the installer to finely adjust the beam easily. 5 degrees of water conditions were [ Horizontally ±90° with hand ] |
|---|
| used to evaluate the protection | [ Vertically ±5° with screwdriver ] against water |
|---|
| Tests were conducted using a water | □ High grade spherical lens |
|---|
| jet stream that applied 12.5 | The high grade spherical lens creates more sharply defined & precise liters/min of water at a distance of infrared beams compared to ordinary fresnel lenses. approximately 3 meters for roughly 3 minutes. This test was directly |
|---|
| applied to the chassis of the AX-TN | □ A.G.C. (Automatic Gain Control) Circuit |
|---|
| and TF series. | A.G.C. circuit continually monitors for gradual changes in the signal's strength caused by changing weather conditions. It adjusts the sensitivity accordingly to maintain the proper signal level for the current environmental conditions. The tests resulted with the AX-TN/TF |
|---|
| unit undamaged due to the highly | □ 99% beam blocking stability durable IP65 rated structure. It aids |
|---|
| in the prevention of water damage to | Enables stable operation with as much as 99% loss of beam energy |
|---|
| the unit while keeping the detector | caused by heavy rain, dust storms, fog or snow. operating accurately in outdoor |
|---|
| environments. | □ Adjustable beam interruption period The beam interruption time can be adjusted to fit any application. For example, when protecting a wall or fence, a longer interruption time will catch intruders. AX-100/200TF only |
|---|
| □ Selectable beam frequencies | □ 4 step alarm indicator LED for fast & accurate optical alignment The selectable beam frequencies can be used to avoid unwanted The alignment condition crosstalk that can occur when using multiple photobeams for long is visually displayed on LED is "ON" |
|---|
| distance or beam stacking applications. | the LED. It shows the Before alignment. alignment condition by 1. Long distance stacking using 4 different process |
|---|
| TRANSMITTER | RECEIVER RECEIVER TRANSMITTER TRANSMITTER RECEIVER to achieve accurate and LED is "Fast Flickering" easy alignment before |
|---|
| Ch1 | Ch1 Ch1 Ch1 Ch3 Ch3 |
|---|
| fine tuning. | Under the beam alignment. LED indication changes by beam receiving level. 2. Two beam long distance |
|---|
| Ch3 | Ch3 Ch3 Ch3 Ch4 Ch4 |
|---|
| under severe outdoor environments. | □ D.Q. Circuit Ready for fine tuning D.Q. circuit (environmental disqualification) sends a trouble signal when snow or other changes in the installation site. The trouble signal output Fine Adjustment with voltmeter |
|---|