  • Detection method:Infrared beam interruption detection (STANDARD MODEL) AX-100
  • Maximum detection range:20m (70ft.) 40m (130ft.) 60m (200ft.) 30m (100ft.) 60m (200f
  • Maximum arrival range:200m (700ft.) 400m (1300ft.) 600m (2000ft.) 300m (1000ft.) 6
  • Interruption period:Selectable between 50, 100, 250, and 500m sec. (ENHANCED MOD
  • Selectable beam frequency:4 channel
HKEZIT 提供原廠行貨保養。硬件連專業安裝、設定及使用教學一站式報價,無需自行研究安裝與設定。我們同時承接裝ALARM、裝防盜、裝警鐘工程,硬件與工程同一團隊負責。
查詢價格連安裝
AX-200TF Optex AX-70 / 130 / 200TN 產品圖片

詳細規格

Detection methodInfrared beam interruption detection (STANDARD MODEL) AX-100 / 200TF
Maximum detection range20m (70ft.) 40m (130ft.) 60m (200ft.) 30m (100ft.) 60m (200ft.)
Maximum arrival range200m (700ft.) 400m (1300ft.) 600m (2000ft.) 300m (1000ft.) 600m (2000ft.)
Interruption periodSelectable between 50, 100, 250, and 500m sec. (ENHANCED MODEL)
Selectable beam frequency4 channel
供電10.5 - 28V DC Current consumption (transmitter + receiver) 38mA (max.) 41mA (max.) 45mA (max.) 44mA (max.) 48mA (max.)
Alarm period2sec. (±1) nominal
警報輸出N.C. 28V DC, 0.2A (max.) N.C./N.O. 28V DC, 0.2A (max.)
D.Q. outputN.C. 28V DC, 0.2A (max.)
Tamper switchOpens when cover is removed at 28V DC, 0.2A max. -35°C to +60°C (-31°F to +140°F) Operating temperature Use the optional heating unit (HU-3) in conditions of -25°C (-13°F) or below.
工作濕度95% max.
Alignment angle± 90° Horizontal, ± 5° Vertical
MountingWall and pole mounting
Weight (transmitter + receiver)650g (22.9oz.) 700g (24.7oz.)
Housing protection (EN 00529)IP65 NOTE: These units are designed to detect an intruder and activate an alarm control panel. Being only a part of a complete system, we cannot accept responsibility for any damages or other consequences resulting from an intrusion. These products conform to the EMC Directive 89/336 ECC.
尺寸OPTIONS ■ HU-3 : Heating Unit Heating unit for severe low temperature conditions 24V DC/AC, 420mA max. 36 (1.4) 1 set (2 units) ■ BC-3 : Back Cover Can be used to cover mounting pole. 83.5 (3.3) 170 (6.7) 1 set (2 units) ■ PSC-3 : Pole Side Cover Cover for installing 2 units to 1 pole. 65 (2.6) 69.5 (2.7) 1 set (2 units) Dimensions : mm (inches) OPTEX CO., LTD. (ISO 9001 Certified by LRQA / ISO140
OPTEX INCORPORATED (USA)http://www.optexamerica.com
OPTEX (EUROPE) LTD. (UK)http://www.optexeurope.com "stable detection performance". OPTEX SECURITY SAS (FRANCE) OPTEX KOREA CO., LTD. (KOREA) http://www.optex-security.com http://www.optexkorea.com These features reduce false alarms drastically caused by outdoor severe environmental changes and
OPTEX SECURITY Sp. z o.o. (POLAND)provide a wide range of applications. “Take Care of the Environment” This catalogue uses recycled paper No. 75107-00-909-0612 AX-70 / 130 / 200TN (STANDARD MODEL)
The best short range photoelectricAX-100 / 200TF (ENHANCED MODEL) □ IP65 structure with high sealing rubber packing □ Anti-frost hood cover
detector from OPTEXRubber packing is used for all conceivable points where water or dust may penetrate, such as wiring holes, wire ports and the outer A hood is installed to prevent frost forming on lower beams. It also makes the maintenance easy because the surface of the cover is flat. □ Lightning protection
chassis. Prevention from dust, bugsAn improved Electro-Magnetic Interference surge absorber and high
and water delivers performance withsurge resistive relay has been installed to protect from lightning surges
higher reliability against false alarmsand maintain stable operation. and breakdowns.
RubberLightning Protection Level packing IP65 Will remain stable against over
Waterproof.Wiring Conventional 14kV of lightning surge.
Protected against water jets fromhole Detector any direction Dust-tight. AX Series No ingress of dust. 0 2 4 6 8 10 12 14
International Protection Code.Lightning Surge Voltage Level (kV) It shows the degress of protection provided by enclosures. □ Easy angle adjustment It allows the installer to finely adjust the beam easily. 5 degrees of water conditions were [ Horizontally ±90° with hand ]
used to evaluate the protection[ Vertically ±5° with screwdriver ] against water
Tests were conducted using a water□ High grade spherical lens
jet stream that applied 12.5The high grade spherical lens creates more sharply defined & precise liters/min of water at a distance of infrared beams compared to ordinary fresnel lenses. approximately 3 meters for roughly 3 minutes. This test was directly
applied to the chassis of the AX-TN□ A.G.C. (Automatic Gain Control) Circuit
and TF series.A.G.C. circuit continually monitors for gradual changes in the signal's strength caused by changing weather conditions. It adjusts the sensitivity accordingly to maintain the proper signal level for the current environmental conditions. The tests resulted with the AX-TN/TF
unit undamaged due to the highly□ 99% beam blocking stability durable IP65 rated structure. It aids
in the prevention of water damage toEnables stable operation with as much as 99% loss of beam energy
the unit while keeping the detectorcaused by heavy rain, dust storms, fog or snow. operating accurately in outdoor
environments.□ Adjustable beam interruption period The beam interruption time can be adjusted to fit any application. For example, when protecting a wall or fence, a longer interruption time will catch intruders. AX-100/200TF only
□ Selectable beam frequencies□ 4 step alarm indicator LED for fast & accurate optical alignment The selectable beam frequencies can be used to avoid unwanted The alignment condition crosstalk that can occur when using multiple photobeams for long is visually displayed on LED is "ON"
distance or beam stacking applications.the LED. It shows the Before alignment. alignment condition by 1. Long distance stacking using 4 different process
TRANSMITTERRECEIVER RECEIVER TRANSMITTER TRANSMITTER RECEIVER to achieve accurate and LED is "Fast Flickering" easy alignment before
Ch1Ch1 Ch1 Ch1 Ch3 Ch3
fine tuning.Under the beam alignment. LED indication changes by beam receiving level. 2. Two beam long distance
Ch3Ch3 Ch3 Ch3 Ch4 Ch4
under severe outdoor environments.□ D.Q. Circuit Ready for fine tuning D.Q. circuit (environmental disqualification) sends a trouble signal when snow or other changes in the installation site. The trouble signal output Fine Adjustment with voltmeter

* 規格以原廠最新 Datasheet 為準。

外形尺寸

AX-200TF 外形尺寸圖 OPTIONS ■ HU-3 : Heating Unit Heating unit for severe low temperature conditions 24V DC/AC, 420mA max. 36 (1.4) 1 set (2

OPTIONS ■ HU-3 : Heating Unit Heating unit for severe low temperature conditions 24V DC/AC, 420mA max. 36 (1.4) 1 set (2

防盜報警安裝工程服務

HKEZIT 專營裝ALARM、裝防盜、裝警鐘工程,AX-200TF 由我們供貨、安裝、調試到使用教學一站式完成。無論裝ALARM、裝防盜或裝警鐘,均由自家工程團隊上門施工,品質有保證。

裝ALARM裝防盜裝警鐘

防盜報警適合邊類專業客戶

AX-200TF Optex AX-70 / 130 / 200TN亦適合以下專業服務機構使用,保安同合規要求同一般商鋪唔一樣,歡迎查詢度身方案。

私人銀行/財富管理

貴賓客戶室高保安等級佈點,配合監管合規存證,出入口身份記錄嚴謹。

WhatsApp 查詢 →

律師事務所

客戶機密文件與會議記錄保安需求高,門禁分級、CCTV存證、通話錄音缺一不可。

WhatsApp 查詢 →

信託公司/家族辦公室

私人會議室同資料保存區極高保密規格,保障客戶身份同資產私隱。

WhatsApp 查詢 →

眼科診所

精密激光同檢查儀器防盜,診症室私隱合規佈點,配合預約系統減少候診糾紛。

WhatsApp 查詢 →

心臟科診所

心電圖同貴重心臟監測儀器防盜,診症室私隱合規佈點,配合預約系統。

WhatsApp 查詢 →

牙科診所

診症室私隱合規佈點、X光及貴重牙科儀器防盜,配合預約系統減少候診糾紛。

WhatsApp 查詢 →

常見問題

AX-200TF 香港哪裡有代理?

HKEZIT 提供原廠行貨連保養,AX-200TF 原廠行貨連保養,提供上門評估、安裝、防區設定及使用教學一站式服務,全港 32 區均有服務。

此設備適合什麼場景?

詳細規格請參閱上方規格表;我們會按現場環境(商舖、辦公室、倉庫、住宅)設計防區及感應器布局,並提供整體方案報價。

觸發警報後如何通知?

可按需求配置本地警號、手機 App 推送或短訊通知;亦可與 CCTV 聯動,觸發時自動錄影存證。

AX-200TF 定 VXS-RAM-2 邊個好?

兩者主要規格分別:Alarm period方面,AX-200TF 係 2sec. (±1) nominal,VXS-RAM-2 係 2.0 ± 0.1 sec. 2.0 ± 0.1 sec.。實際邊個型號更適合,需視乎現場環境同需求而定,可先比較 VXS-RAM-2 詳細規格,或直接聯絡我們免費現場評估,由工程師建議最合適方案。

AX-200TF 保養、維修邊度做?

HKEZIT 提供 AX-200TF 原廠行貨連保養,安裝後如有故障可直接聯絡我們安排上門維修,毋須自行聯絡原廠。詳情請參閱防盜報警安裝工程頁面或聯絡我們查詢保養範圍。

香港安裝服務地區

HKEZIT 於全港各區提供 AX-200TF Optex AX-70 / 130 / 200TN供貨連專業安裝服務(裝ALARM、裝防盜、裝警鐘),熱門地區包括:九龍灣防盜報警系統安裝佐敦防盜報警系統安裝元朗防盜報警系統安裝北角防盜報警系統安裝土瓜灣防盜報警系統安裝大圍防盜報警系統安裝大埔防盜報警系統安裝大角咀防盜報警系統安裝。港島、九龍、新界全港 32 區均有上門安裝,歡迎聯絡我們查詢 AX-200TF 香港價格連安裝報價。

防盜報警適用場景

AX-200TF Optex AX-70 / 130 / 200TN適合多種場景使用,以下為部分常見安裝場景,歡迎查詢是否適合您的現場環境。

查看更多防盜報警適用場景,請參閱 防盜報警安裝工程

相關產品

如需整套防盜報警方案,請參閱 防盜報警安裝工程

查詢 AX-200TF 連安裝價格

免費上門評估,即日報價,原廠行貨保養

立即查詢