| 重設 | Reset button to reset the device to factory |
|---|
| 按鈕 | default 3 31-00424 | Rev.10-20 |
|---|
| TECHNICAL DATA | Table 5. Standards |
|---|
| System | The system transformer(s) must be |
|---|
| System Data | Transformer safety isolating transformers according to IEC 61558-2-6. In the U.S.A. and Canada, NEC Class 2 Table 2. System Data transformers must be used. Operating 19 to 29 Vac (50/60Hz) |
|---|
| Voltage (AC) | Operating Environment Operating 19 to 29 Vdc Table 6. Operating Environment Voltage (DC) |
|---|
| Overvoltage | Protected against overvoltages of Ambient 0 to 50 °C (32 to 122 °F) |
|---|
| 防護等級 | max. 29 Vac or 40 Vdc. Terminals are Operating |
|---|
| protected against short-circuiting. | Temperature |
|---|
| Ambient | 5 to 95% relative humidity (non- |
|---|
| 功耗 | Operating Humidity condensing) |
|---|
| Table 3. Power Consumption | Storage -28.9 to +70 °C (-20 to 158 °F) Temperature Power |
|---|
| Gateway | Ambient 5 to 95% relative humidity (non- 24 Vac 24 Vdc Storage condensing) Humidity |
|---|
| GW-1000-WE/GW- | Max. 35VA Max. 15W 1000-NWE Vibration 0.024” double amplitude (2 to 30 Hz), |
|---|
| Under | 0.6 g (30 to 300 Hz) Operation |
|---|
| Dust, Vibration | According to EN60730-1 Table 4. Current Consumption |
|---|
| RFI, EMI | Residential, commercial, and light- |
|---|
| 供電 | industrial environments Gateway 24 Vac 24 Vdc MTBF (Mean 11.5 years Time Between |
|---|
| Product | CAN/CSA-E60730-1:02, Ethernet |
|---|
| Standards | Protocol version IEEE 802.3 |
|---|
| Testing | IEC68 Electrical Components |
|---|
| Certification | • UL60730-1 |
|---|
| • | UL916 |
|---|
| Communication Baud Rates | Gateway Parameters |
|---|
| Table 7. Communication Baud Rates | Table 8. Gateway Parameters |
|---|
| Ethernet | 10/100/1000 Mbit/s, RJ45 Max number of points 3000 |
|---|
| BACnet MSTP | 9.6, 19.2, 38.4, 76.8, 115.2 Kbps Max trend retention 2 days (1 min samples) |
|---|
| WiFi | 802.11b: up to 11Mbps 802.11g: up to 54Mbps Max number of alarms retained 70000 Records 802.11n: up to 150Mbps |
|---|
| History push | Per Minute |
|---|
| 藍牙 | BR: up to 1Mbps |
|---|
| EDR: up to 3Mbps | GW OTA Upgrade check Once in 4 hours BLE: up to 1Mbps |
|---|
| Devices OTA Upgrade check | Once in 24 hours |
|---|
| Wi-Fi Range with | 100 ft |
|---|
| unobstructed | Max rumen of devices in Wifi 12 |
|---|
| line of sight | interface |
|---|
| Supported type | Wi-Fi Access Point - Providing |
|---|
| of Wi-Fi | access point to IO-10MIXR-WE/IO- Gateway Ordering Part Numbers |
|---|
| connections | 10MIXR-NWE Smart IO and |
|---|
| TC500A-N Commercial Thermostat | Table 9. Gateway Part Numbers devices |
|---|
| Part Number | Description |
|---|
| GW-1000-WE | Wireless Gateway with European and Latin American conformance |
|---|
| GW-1000-NWE | Wireless Gateway with North American conformance 5 31-00424 | Rev.10-20 Table 10. Accessories |
|---|
| Antenna Part Numbers | Vendor Name Type Gain |
|---|
| CA #ANTT935-4 | ADAM External 2.4 GHz: 2.9dbi |
|---|
| ANT-DB1-LCD-SMA | LINX External 2.4 GHz: 2.8dbi 145.8 mm (5.744") 110 mm 45 mm (4.331") (1.772") 135 mm 52 mm (5.315") (2.047") 59 mm (2.323") 7 31-00424 | Rev.10-20 |
|---|
| GENERAL SAFETY | Safety Information as per EN60730-1 |
|---|
| INFORMATION | The GW-1000-WE/GW-1000-NWE Gateway is intended for residential, commercial, and light-industrial environments. start-up), all manufacturer instructions and in The GW-1000-WE/GW-1000-NWE Gateway is an particular the Installation and Commissioning independently mounted electronic control system with Instructions (EN1B-0077IE10) are to be observed. fixed wiring. installed and mounted only by authoriz |
|---|
| personnel. | mounting in fuse boxes conforming with standard followed. modified in any way, except by the manufacturer, all panel rail (both horizontal and vertical rail mounting warranties concerning operation and safety are possible). |
|---|
| invalidated. | The GW-1000-WE/GW-1000-NWE is used for the purpose observed at all times. Examples of such regulations are non-safety controls for installation on or in appliances. VDE 0800 and VDE 0100 or EN 60204-1 for earth grounding. Table 12. Safety Information as per EN60730-1 been approved by Honeywell. temperature for at least 24 hours before applying Protection power. This is to allow any condensation re |
|---|
| Pollution Degree | Pollution Degree 2, suitable for use low shipping/storage temperatures to evaporate. in industrial environments. installed in a manner (e.g., in a lockable cabinet) Installation Class 3 ensuring that unauthorized persons have no access to |
|---|
| the terminals. | Overvoltage 24 V-powered controls: Category I 60730-1,UL-916, and UL60730-2-9. Standard(s) C22.2, No. 205-M1983 (CNL-listed). Voltage contains no user-serviceable parts inside! Automatic Type1.Y 2014/35/EU and EMC Directive 2014/30/EU. |
|---|
| Professional Installation | Enclosure IP20 according to EN-60529 |
|---|
| should be noted on grantee. | Test parts have been tested shall be used, which listed in “Remote applied with voltage-carrying parts, Antenna Part Numbers” on page 6. This device requires connectors, and terminals. a significant technology engineering expertise towards understanding of the tools and relevant technology, not Electromagnetic Tested at 230 Vac, with the readily available to average consumer. Only a person Interfe |
|---|
| public. | Transformer transformers according to IEC61558-2-6 U.S.A. and Canada: NEC Class-2 transformers ® U.S. Registered Trademark |
|---|
| customer.honeywell.com | © 2020 Honeywell International Inc. 31-00424 | Rev.10-20 |
|---|