| market, lower total system costs, and | using Hall-effect technology |
|---|
| • High accuracy and low temperature | PORTFOLIO |
|---|
| drift | Honeywell offers a variety of current |
|---|
| Honeywell provides global technical | • Operating temperature of sensors for potential use in many |
|---|
| assistance and engineering/service | -40°C to 125°C [-40°F to 257°F] applications. To view the entire |
|---|
| support. | • Analog voltage output product portfolio, click here. • CE and UKCA certification; REACH and RoHS compliant • AEC-Q100 qualified for higher reliability TABLE 1. ABSOLUTE MAXIMUM RATINGS (not operating) Parameter |
|---|
| Characteristic | Symbol Unit Condition |
|---|
| Min. | Typ. Max. |
|---|
| Supply voltage max. | VS max. V — — 10 — |
|---|
| Reverse supply voltage max. | VR max. V -0.3 — — — |
|---|
| Output voltage max. | VOUT max. V -0.3 — 10 VOUT reverse/forward voltage |
|---|
| Output current max. | IOUT max. mA -10 — 10 — |
|---|
| Ambient storage temperature | — °C -40 — 125 — |
|---|
| Electrostatic discharge voltage | VESD kV — — 8 — |
|---|
| RMS voltage for AC isolation test | VDWV kV — — 2.5 50 Hz, 1 min |
|---|
| Creepage distance | dCp mm 4.9 — — — |
|---|
| Clearance | dCl mm 4.9 — — — |
|---|
| Comparative tracking index | CTI — PLC3 — — — TABLE 2. OPERATING CHARACTERISTICS IN NOMINAL RANGE (IPN) Parameter |
|---|
| Primary current, nominal DC | IPN A -IPN — IPN — |
|---|
| Supply voltage | VS V 4.5 5 5.5 — |
|---|
| Output voltage | VOUT V VOUT = (G * IP + VOS) IP = (VOUT * 5 - VOS) / G 5 VS |
|---|
| Output voltage (at IP = 0) | VOS V — 2.500 — — |
|---|
| Electrical offset voltage | VOS, ELECT mV — ±3 — TA = 25°C, VS = 5 V |
|---|
| Magnetic offset voltage | VOS, MAG mV — ±2 — TA = 25°C, VS = 5 V |
|---|
| — | 13 — TA = 25°C, VS = 5 V |
|---|
| Current consumption | ISUPPLY mA |
|---|
| Load resistance | RL Ohm 10k — — — |
|---|
| Output impedance | Rout Ohm |
|---|
| Ratiometric error | εr % — ±0.5 — — |
|---|
| 靈敏度 | G mV/A — 2000/IPN — TA = 25°C Sensitivity error: |
|---|
| ±100 A to ±1200 A | εg % — ±0.6 — TA = 25°C, VS = 5 V |
|---|
| ±1500 A | — ±0.8 — TA = 25°C, VS = 5 V |
|---|
| Linearity error | εL % -1 — 1 % of full scale output |
|---|
| Ambient operating temperature | — °C -40 — 125 — |
|---|
| Average temperature coefficient | VOS, ELECT mV/°C — ±0.04 — — |
|---|
| Average temperature coefficient of G | — %/°C — ±0.02 — — |
|---|
| Step response time (10 % to 90 %) | tr µs — 2 6 — |
|---|
| Frequency bandwidth | BW kHz 45 — — -3 dB |
|---|
| Output RMS noise (RMS) | — mV — — 2 — See Table 4 for catalog listing specifics. |
|---|
| Housing material | PBT + GF30 % |
|---|
| Mounting screw | M4, 2,5 N m torque max. |
|---|
| Mating electrical connector | TE MPN 1473672-1 |
|---|
| 重量 | 58 g ±5 g |
|---|
| Measure | Offset Accuracy |
|---|
| Catalog Listing | Range (mV/A at VS = 5 V) (A) 25°C -40°C to 85°C 25°C -40°C to 85°C |
|---|
| CSHV100A-001 | ±100 20 ±7 mV ±25 mV ±1 % ±2 % |
|---|
| CSHV200A-001 | ±200 10 ±7 mV ±15 mV ±1 % ±2 % |
|---|
| -40°C to | -40°C to 25°C 25°C 125°C 125°C |
|---|
| CSHV300A-001 | ±300 6.667 ±7 mV ±18 mV ±1 % ±2 % |
|---|
| CSHV400A-001 | ±400 5 ±7 mV ±13 mV ±1 % ±2 % |
|---|
| CSHV500A-001 | ±500 4 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV600A-001 | ±600 3.333 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV700A-001 | ±700 2.857 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV800A-001 | ±800 2.5 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV900A-001 | ±900 2.222 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV1000A-001 | ±1000 2 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV1100A-001 | ±1100 1.818 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV1200A-001 | ±1200 1.667 ±7 mV ±10 mV ±1 % ±2 % |
|---|
| CSHV1500A-001 | ±1500 1.333 ±7 mV ±10 mV ±2 % ±3 % |
|---|
| CS | H V 1500 A 001 |
|---|
| 類型 | Principle Use Rated Current Output Version Configuration |
|---|
| Current H Hall based | Designed 100 100 A A One channel 001 ASIC 1 |
|---|
| Sensor | V for vehicle |
|---|
| applications | 200 200 A 300 300 A 400 400 A 500 500 A 600 600 A 700 700 A 800 800 A 900 900 A 1000 1000 A 1100 1100 A 1200 1200 A 1500 1500 A CSHV Series Datasheet | sps.honeywell.com/ast | 3 POSITIVE PRIMARY CURRENT DIRECTION 24,35 [0.96] 38,4 SEE DETAIL A [1.51] 26,3 6 [0.12] |
|---|
| [1.04] | [0.24] 2,5 [0.10] |
|---|
| [0.40] | 5 [0.20] 2,5 20,5 [0.10] 3 |
|---|
| [0.71] | 6,15 [0.12] 40 [0.24] |
|---|
| [1.58] | 32,15 |
|---|
| ø4,15 | [1.27] [0.16] M4 NUT CAVITY 4,5 DEEP 7,1 [0.18] TABLE 5. PINOUT [0.28] |
|---|
| Pin | Output 1 VOUT 20,00 2 GND [0.79] 3 VS (5 V) 18,15 [0.71] 4 no connection |
|---|
| DETAIL A | Mating connector: TE MPN 1473672-1 2D Barcode includes: C SHV700A- 001: C ATALOG LISTING (E X AMPLE ) AY YDDD000N: SN CODE A : A S SEMBLY LINE CODE Y T: PAR T PRODUC TION YE AR DDD: DAY OF THE YE AR 000N: DAILY PAR T PRODUC TION NUMBER CSHV Series Sensor Magnetic core |
|---|
| C1: 100 nF, decoupling | NOTICE C2: 10 nF, EMC protection SENSOR ACCESSIBILITY |
|---|
| Busbar/ | Hall- • Ensure that the current sensor is installed in a suitable |
|---|
| primary | effect Amplification VOUT |
|---|
| conductor | element electrical enclosure which is only accessible with the GND |
|---|
| VS | use of special tools. |
|---|
| C2 | C1 |
|---|
| Test | Standard Procedure |
|---|
| CISPR25 | According to CISPR 25:2008 Commission Form of Testing |
|---|
| CISPR 25 Radiated Emissions | CISPR25 According to CISPR 25:2008 Commission Form of Testing |
|---|
| Bulk Current Injection (BCI) Test | ISO 11452-4 According to ISO 11452-4 |
|---|
| RF Radiated Immunity - ALSE | IEC 61000-4-3 According to ISO IEC 61000-4-3 Unpowered direct contact discharge: ±8 kV Unpowered air discharge: ±15 kV |
|---|
| Electrostatic Discharge | ISO 10605 Powered-up direct contact discharge: ±4 kV Powered-up air discharge: ±8 kV |
|---|
| Fast Transients Burst Immunity Test | IEC 61000-4-4 2 kV Power port, 1 kV signal port |
|---|
| Magnetic Field Emission Test | IEC 61000-4-8 20 kHz to 200 kHz |
|---|
| Conducted/Coupled Immunity | ISO 11452-4 According to ISO 11452-4, test CCC and ICC |
|---|
| ISO16750-2-4.9 | Disconnect Us, GND, Us & GND for twice. Each open circuit time :60 ±1 second & 10 ± 1 second Connect sensor to power supply and power on the sensor by 5 V. Apply short |
|---|
| Short Circuit Protection | ISO 16750-2-4.10 circuit between Vout & GND, Vout & Us. Each hold for 60 seconds |
|---|
| ISO 16750-2-4.12 | 500 Vdc ±10 Vdc for 60 s; Resistance criteria: ≥100 MOhm |
|---|
| dc & ac Voltage | Test voltage: 2500 Vdc & 2500 Vac. Frequency: dc & 50~60 Hz. Test |
|---|
| Insulation Test | duration: 60 seconds |
|---|
| ISO16750-4 | 48 hour, 85°C. Performance test before and after test from −40°C to 85°C |
|---|
| Thermal Cycle Test | ISO16750-4 soak). Transition time = 270 minutes. Performance test before and after test from −40°C to 85°C 10 Hz to 200 Hz, 10.95 hour/axis, 3 axis. Performance test before and after |
|---|
| Vibration | SAE J2380 test from −40°C to 85°C 500 m/s, 20 each direction (60 total), half sine pulse. Performance test |
|---|
| Mechanical Shock | ISO16750-3 before and after test from −40 °C to 85 °C 1st fall of each DUT at a different dimensional axis, 2nd fall with the given DUT at the same dimensional axis but on the opposite side of the housing, |
|---|
| Handling Drop | ISO 16750-3 from 1 m on concrete floor. Performance test before and after test from −40°C to 85°C |
|---|
| High Temperature | 3000 hour, 85°C. Performance test before and after test from −40°C to ISO16750-4 |
|---|
| Durability Test | 85°C CSHV Series Datasheet | sps.honeywell.com/ast | 5 m WARNING |
|---|
| Honeywell warrants goods of its | PERSONAL INJURY manufacture as being free of defective DO NOT USE these products as safety |
|---|
| materials and faulty workmanship | or emergency stop devices or in any |
|---|
| during the applicable warranty period. | other application where failure of the |
|---|
| Honeywell’s standard product warranty | product could result in personal injury. |
|---|
| applies unless agreed to otherwise by | Failure to comply with these |
|---|
| Honeywell in writing; please refer to | instructions could result in death or |
|---|
| your order acknowledgment or consult | serious injury. your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the m WARNING |
|---|
| period of coverage, Honeywell will | MISUSE OF |
|---|
| repair or replace, at its option, without | DOCUMENTATION |
|---|
| charge those items that Honeywell, | • The information presented in this |
|---|
| in its sole discretion, finds defective. | product sheet is for reference only. Do not use this document as The foregoing is buyer’s sole remedy a product installation guide. |
|---|
| and is in lieu of all other warranties, | • Complete installation, operation, |
|---|
| expressed or implied, including those | and maintenance information |
|---|
| of merchantability and fitness for a | is provided in the instructions |
|---|
| particular purpose. In no event shall | supplied with each product. |
|---|
| Honeywell be liable for consequential, | Failure to comply with these |
|---|
| special, or indirect damages. | instructions could result in death or serious injury. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this writing. Howeve |
|---|
| USA/Canada | +1 302 613 4491 |
|---|
| Latin America | +1 305 805 8188 |
|---|
| Europe | +44 1344 238258 |
|---|
| Japan | +81 (0) 3-6730-7152 |
|---|
| Singapore | +65 6355 2828 |
|---|
| Greater China | +86 4006396841 005999-6-EN | 6 | 01/24 |
|---|
| www.honeywell.com | © 2024 Honeywell International Inc. All rights reserved. |
|---|