CAMBIUM 60GHZ 安裝、保養、維修

60GHZ

裝WIFI | 裝ROUTER | 裝FIREWALL — 硬件連工程一站式

產品簡介

Cambium 60GHZ 為60 GHZ cnWave™,HKEZIT 提供原廠行貨連保養、上門安裝、調試及使用教學一站式服務。詳細規格以下方原廠 Datasheet 欄位為準,歡迎聯絡我們查詢 60GHZ 香港價格連安裝報價。

  • V5000 Distribution Node:IEEE 802.3af/at, 25 W maximum
  • System Hardware:43
  • l:Distribution Node (DN) - DN connects with other DN for mesh
  • Cambium description:Radio node Cambium part number
  • Outdoor AC/DC PSU, 100W, 54V DC:V3000, V5000 N000000L179B
HKEZIT 提供原廠行貨保養。硬件連專業安裝、設定及使用教學一站式報價,無需自行研究安裝與設定。我們同時承接裝WIFI、裝ROUTER、裝FIREWALL工程,硬件與工程同一團隊負責。
查詢價格連安裝
60GHZ Cambium 60 GHZ cnWave™ 產品圖片

詳細規格

V5000 Distribution NodeIEEE 802.3af/at, 25 W maximum
System Hardware43
lDistribution Node (DN) - DN connects with other DN for mesh network
Cambium descriptionRadio node Cambium part number
Outdoor AC/DC PSU, 100W, 54V DCV3000, V5000 N000000L179B
Waterproof PSU Cable Joiner 14-16 AWGV3000, V5000 N000000L180A
DC to RJ45 Plug Power AdaptorV3000, V5000 C000000L184A
Cable Gland, Long, M25, Qty 5V3000, V5000 C000000L124A
AC power Injector 56V, 60WV3000, V5000 N000065L001C V5000
CABLE, UL POWER SUPPLY CORD SET, INDIAV1000, V3000, N000900L012A V5000 V5000
CABLE, UL POWER SUPPLY CORD SET, CHINAV1000, V3000, N000900L015A V5000 V5000 V5000 V5000 V5000 V5000
CategorySpecification
尺寸118 mm (4.64 in) x 43 mm (1.69 in) x 32.4 mm (1.27 in)
重量0.18 Kg (0.39 lbs)
Temperature0°C (32°F) to +50°C (140°F)
Humidity10% to 95 % non-condensing
AC Input90-264V AC, 47-63 Hz
DC Output Voltage56V
DC Output current0.25A
EfficiencyBetter than 84% at full load
Over Current ProtectionHiccup mode, recovers automatically after the fault condition is removed
Hold up timeAt least 10 milliseconds
RJ45 POE Port7,8 ------------- DC V- 5,6 ------------- DC V+ Note The Gigabit power injector is supplied with the cnWave V1000 CN. Order part N000900L017A to obtain spares. Warning Always use an appropriately rated and approved AC supply cord-set in accordance with the regulations of the country of use.
DC Output voltage56V
Part number andN000000L178A (60W) 171 mm (6.7 in) x 62 mm (2.4 in) x 37 mm
N000000L179A(100W)220 mm (8.7 in) x 68 mm (2.7 in) x 39 mm (1.5 in)
供電60W 100W
WaterproofingIP65/IP67
Power factorBetter than 0.95 Figure 33: Cable joiner Figure 34: DC to RJ45 plug power adapter
RadioPoE enabled Maximum cable length
V3000- 390m 25W 72m
V5000- 330m 25W Not supported
CAT6A outdoor cable, 305mN000082L172B
RJ45 connector for CAT6A cableN000082L174B
CAT6A outdoor cable, 100mN000000L155A
Cable gland for 4-6mm cable, M25, Qty 10C000000L176A
Cable gland for 6-9mm cable, M25, Qty 10C000000L123A
CAT5E Outdoor Cable, 100m drumN000082L016A
Cable gland Long, M25, Qty 5C000000L124A
DC to RJ45 plug power adapterC000000L184A Note One cable gland for 6-9mm cable size is included with each cnWave radio. Order additional cable glands as spares, where smaller cable size is to be used, or where the V3000 or V5000 Aux port is to be used.
Optical CABLE,MM, 1mN000082L215A
Optical CABLE,MM, 2.2mN000082L191A
Optical CABLE,MM, 10mN000082L192A
Optical CABLE,MM, 20mN000082L193A
Optical CABLE,MM, 30mN000082L194A
Optical CABLE,MM, 50mN000082L195A
Optical CABLE,MM, 80mN000082L196A
Optical CABLE,MM, 100mN000082L197A
Optical CABLE,MM, 150mN000082L198A
Optical CABLE,MM, 200mN000082L199A
Optical CABLE,MM, 300mN000082L200A
Optical CABLE,SM, 2.2mN000082L186A
Optical CABLE,SM, 10mN000082L187A
Optical CABLE,SM, 20mN000082L188A
Optical CABLE,SM, 30mN000082L139A
Optical CABLE,SM, 50mN000082L140A
Optical CABLE,SM, 80mN000082L141A
Optical CABLE,SM, 100mN000082L142A
Optical CABLE,SM, 150mN000082L143A
Optical CABLE,SM, 200mN000082L189A
Optical CABLE,SM, 300mN000082L190A
System Planning56 Never mount equipment in Zone A. Mounting in Zone A may put equipment, structures and life at risk.
Type of ODUMax surface area (square meters) Wind speed (km/h Newtons) 200* 225 250 275 300 325
V10000.017544 67 85 105 127 151 177
v3000**0.1764 462 583 719 871 1036 1216
ItemSpecification
ChannelOpen/R protocol or manual selection selection
Manual powerSupports ATPC automatic transmit power control and maximum EIRP can be set
controllower than the default power limit.
Integratedl V3000 44.5 dBi gain and 40.5 dBi gain antenna type
Duplex schemesSymmetric 50:50 fixed and asymmetric fixed
Range100 m to 2 KMs, depends on the following factors:
Over-the-airAES 128-bit encryption
WeatherHighly sensitive due to rain range conditions. For more information in range, refer
靈敏度Rain and attenuation table.
FrequencyPower / Magnetic Field Band
c257 - 71 40 dBm E.I.R.P., 23 dBm/MHz E.I.R.P. density and maximum transmit power of 27
GHzdBm at the antenna port/ports.
c357-71 55 dBm E.I.R.P., 38 dBm/MHz E.I.R.P. density and transmit antenna gain ≥ 30 dBi. GHz
Site NameSite Location Radius of exclusion zone from the center of site location
Site 107° 23’ 36.6” W, 57° 21’ 3.6” N 6 Km
Site 204° 58’ 21” W, 51° 37’ 16.8” N 6 Km
Site 300° 36’ 22.8” W, 52° 38’ 1.8” N 6 Km
Where:Is:
Lfree_spaceFree Space Path Loss (dB)
LexcessExcess Path Loss (dB)
LfadeFade Margin Required (dB)
LseasonalSeasonal Fading (dB)
LcapabilityEquipment Capability (dB)
安裝74
BracketPole diameter ODU Bracket part number variants
V1000 pole mount40 mm to 77 mm (1.6 inches V1000 Included with V1000 to 3.0 inches)
V1000 wall mountWall mount V1000 Included with V1000
V1000 adjustable pole mount40 mm to 77 mm (1.6 inches V1000 N000900L022A to 3.0 inches)
V3000 precision bracket25 mm to 77 mm (1.0 inches V3000 C000000L125A to 3.0 inches)
V3000 tilt bracket assembly40 mm to 77 mm (1.6 inches V3000, N000045L002A
to 3.0 inches)V5000
with band clampsinches to 9.0 inches) V5000 party band clamps
V5000 pole mount25 mm to 77 mm (1.0 inches V5000 C000000L137A to 3.0 inches)
V5000 wall mountWall mount V5000 C000000L136A 1. Typical installation 2. ODU interface with LPU on the pole 3. SFP and Aux Ethernet interfaces
Figure 106: AC/DC PSUFigure 107: Cable joiner Figure 108: DC to (N000000L179B) RJ45 plug, Mini adaptor
Figure 109: AC/DC powering diagramFigure 110: AC/DC PSU Note Both short and long glands can be used to connect to outdoor PSU. 1. Connect the 56V Gigabit Data + power port to ODU and Gigabit data port to the network equipment.
Figure 111: V1000 power injectorFigure 112: V1000 powering diagram Figure 113: Connecting the V1000 power injector
OpticalCopper
Optical SFP+ moduleCopper SFP module 2. Insert the SFP module into the SFP receptacle with the label on the bottom. Figure 119: Inserting the SFP module
Configuring 60 GHz cnWave112 Internet > Network Connections > Local Area Connection. 2. Select Internet Protocol Version 4 (TCP/IPv4). Figure 130: The Ethernet Properties dialog box 3. Click Properties. 4. Enter an IP address that is valid for the 169.254.X.X/16 network, avoiding 169.254.1.1 (eg: 169.254.1.3).
ElementDescription
類型Displays type of the device. The device types are:
NameDisplays name of the device.
E2E Connection StatusDisplays the connection status of the E2E controller.
MAC addressDisplays the MAC address of the 60 GHz cnWave device.
Serial NumberDisplays the serial number of the 60 GHz cnWave device
Software versionDisplays the software version used in 60 GHz cnWave device.
韌體版本Displays the Firmware version used in 60 GHz cnWave device.
Wireless securityDisplays the security type. The types are:
Layer 2 BridgeDisplays bridge status.
System TimeDisplays current time. Figure 136: Dashboard - GPS
Fix TypeFix Type
Satellites trackedNumber of registered satellites
LatitudeDisplays latitude of the site
LongitudeDisplays longitude of the site
HeightDisplays height of the device Figure 137: Dashboard - Sectors
Sync modeDisplays the sync mode of the sectors
Active linksDisplays the number of active links in connected sectors
RX ThroughputDisplays RX Throughput of the individual sectors
TX ThroughputDisplays TX Throughput of the individual sectors Figure 138: Dashboard - Ethernet
StatusDisplays the speed of Ethernet ports
RX PacketsNumber of packets received
TX PacketsNumber of packets transmitted
ElementsDescription
TransmitTransmit power of the radio Power
AdaptiveSelect minimum and maximum coding scheme ranging from 2 to 12. Modulation
Sector 1l Select the frequency channel and polarity.
Sector 1 LinkGolay codes help in avoiding inter-sector interference. In rare scenarios, individual links (s) Golay might require separate Golay codes. In most scenarios, all the links belonging to a sector are configured same Golay code. The controller automatically sets the Golay code. To manually override, select the check box and set the Golay from the drop- down. Override All button helps in setting the sa
Sector 2Select the frequency channel and polarity.
Sector 2 LinkGolay code. (s) Golay
GPSIf enabled then, the radio uses internal sync rather than the GPS sync. In some scenarios like lab setups, it may be necessary to disable GPS. Caution 60 GHz cnWave V1000 and V3000 devices has only Sector 1. Figure 160: The Antenna section Caution Small dish is supported only for 60 GHz cnWave V3000.
IPv4Static IPv4 address of the individual node. Node’s GUI /CLI can be opened using
Addressthis IP address when directly connected over Ethernet. For Over the air access, L2 Bridge should be enabled. Its predominantly used on PoP nodes with the onboard controller.
SubnetSubnet mask for the IPv4 address. Mask
GatewayIPv4 Gateway address. IP Address 2. Under PoP Configuration, select the options for PoP Routing, PoP Interface, and click Generate to generate PoP Interface IP Address.
PoPPoP nodes connect to the upstream IPv6 router in one of two ways: Routing
接口when the L2 bridge is enabled.
IPv6Gateway address. Can be left empty when the L2 bridge is enabled and no IPV6
E2E IPv6 AddressAddress of E2E Controller. When using the onboard controller on the same node, can be left empty and GUI automatically fills the POP IPv6 address.
E2E Network PrefixSeed Prefix in the CIDR format followed by a comma and the prefix length. Should be specified when BGP is used. Otherwise, optional.
IPv6 CPE InterfaceIPv6 SLAAC provides IP prefix to downstream CPE devices. Keep it disabled when L2 Bridge is active. 4. Select required BGP configuration. Figure 163: The BGP Configuration section Table 39: Elements in the BGP Configuration section
Local ASNLocal ASN
Neighbour ASNUpstream router's ASN
Neighbour IPv6Upstream router's IPv6 address
Specific Network prefixesSpecifically allocated network prefixes to be advertised via BGP 5. Enable the required Ethernet ports. Individual Ethernet ports can be turned off with this configuration.
Layer 2It has three options: Bridge
CPEIPv6 SLAAC provides IP prefix to downstream CPE devices. Disable this if the L2 bridge is active. Select the CPE interface:
Aux PoEEnable PoE out (25 W) on V5000/V3000 aux port. 802.3af and 802.3at compliant devices could be powered up, passive PoE devices cannot be powered up. Note that the aux port cannot power another V5000/V3000.
Relay PortSpecify the Ethernet interfaces on which OpenR is running. It is needed in two cases:
Operation149 After selecting the software image, the upload status is displayed. Figure 185: The Images page A pop-up message is displayed after the upload.
Link NameLink name
A-NodeInitiator Node
Z-NodeResponder Node
RSSIReceiver Signal Strength Indicator
信噪比 SNRSignal to Noise Ratio
MCSModulation Coded Scheme
TX Power IndexTransmitter power index
RX FramesReceiver frames
RX ErrorsReceiver errors
RX PERReceiver packer error rate
RX Beam IndexReceiver beam index
TX FramesTransmitter frames
TX ErrorsTransmitter errors
TX PERTransmitter packer error rate
TX Beam IndexTransmitter beam index Figure 192: The Ethernet page
Device NameName of the device
RX BytesReceiver bytes
TX BytesTransmitter bytes
RX DroppedReceiver dropped
TX DroppedTransmitter dropped
RX PPSReceiver Packets Per Second
TX PPSTransmitter Packets Per Second
DeviceName of the device
MACMAC address of the device
SatellitesThe number of satellites tracked tracked
MAC AddressMAC address of the device
Sync Model GPS sync: l Entry condition: Valid samples from GPS have been received for a few consecutive seconds (typically 2 seconds).
安全Security type
ErrorError Association
Channel LastChannel Last State
MCS IndexModulation and Coding Scheme (MCS) Index Values can be used to determine the likely data rate of your wireless connection. The MCS value essentially summarizes the number of spatial streams, the modulation type and the coding rate that is possible when connecting your wireless access point.
Packet ErrorPacket error ratio. It is the ratio, in percent, of the number of Test Packets not
Ratiosuccessfully received by the node to the number of Test Packets sent to the node by the test set.
ReceivedThe number of frames received at the node.
TransferredThe number of frames transferred from the node. Figure 196: RSSI graph
RegionSpecification
USAUL 62368-1, UL 60950-22
CanadaCSA C22.2 No.62368-1, CSA C22.2 No. 60950-22
EuropeEN 62368-1, EN 60950-22
InternationalCB certified IEC 62368-1 Edition 2 IEC 60950 -22
Regulatory Information170
Europe/InternationalEN 301 489-1 V2.2.3, EN 301 489-17 V3.2.4
ProductCountries EIRP EIRP Maximum power density Compliance distance (dBm) (W) (W/m2) (m)
AccessoriesRadio nodes Cambium Part Number 60 GHz cnWave™ V5000 Distribution Node V5000 C6000500A004A 60 GHz cnWave™ V3000 Client Node radio only V3000 C600500C024A 60 GHz cnWave™ V1000 Client Node with no cord V1000 C600500C14A 60 GHz cnWave™ V1000 with US cord V1000 C600500C001A
Troubleshooting177 Figure 222: Saving the log files 1. Click Configuration on the left pane, navigate to Network > Basic > Layer 2 Bridge and verify Enable Layer 2 bridge is selected.
User Guideshttp://www.cambiumnetworks.com/guides
Technical traininghttps://learning.cambiumnetworks.com
Support websitehttps://support.cambiumnetworks.com
Main websitehttp://www.cambiumnetworks.com
Sales enquiriessolutions@cambiumnetworks.com
Support enquirieshttps://support.cambiumnetworks.com Telephone number list http://www.cambiumnetworks.com/contact-us/
Cambium Networks187

* 規格以原廠最新 Datasheet 為準。

下載完整PDF規格書

外形尺寸

60GHZ 外形尺寸圖 118 mm (4.64 in) x 43 mm (1.69 in) x 32.4 mm (1.27 in)|重量 0.18 Kg (0.39 lbs)|Unit: mm

118 mm (4.64 in) x 43 mm (1.69 in) x 32.4 mm (1.27 in)|重量 0.18 Kg (0.39 lbs)|Unit: mm

網絡 WiFi安裝工程服務

HKEZIT 專營裝WIFI、裝ROUTER、裝FIREWALL工程,60GHZ 由我們供貨、安裝、調試到使用教學一站式完成。無論裝WIFI、裝ROUTER或裝FIREWALL,均由自家工程團隊上門施工,品質有保證。

裝WIFI裝ROUTER裝FIREWALL

網絡 WiFi適合邊類專業客戶

60GHZ Cambium 60 GHZ cnWave™亦適合以下專業服務機構使用,保安同合規要求同一般商鋪唔一樣,歡迎查詢度身方案。

心臟科診所

心電圖同貴重心臟監測儀器防盜,診症室私隱合規佈點,配合預約系統。

WhatsApp 查詢 →

脊醫/物理治療中心

治療室私隱同貴重儀器防盜,配合預約系統管理,減少候診糾紛。

WhatsApp 查詢 →

會計師行

審計旺季外勤同事考勤管理、財務資料室保安,同會計師行嘅合規要求相符。

WhatsApp 查詢 →

測量師行/則師樓

現場勘察資料同客戶物業圖則屬機密,辦公室網絡同門禁保安係基本要求。

WhatsApp 查詢 →

建築工程顧問公司

圖則模型檔案室保密,配合工地現場監控延伸管理,項目資料防外洩。

WhatsApp 查詢 →

律師事務所

客戶機密文件與會議記錄保安需求高,門禁分級、CCTV存證、通話錄音缺一不可。

WhatsApp 查詢 →

常見問題

60GHZ 香港哪裡有代理?

HKEZIT 提供原廠行貨連保養,60GHZ 原廠行貨連保養,提供上門安裝、佈線及網絡設定一站式服務,全港 32 區均有服務。

此設備適合什麼工程場景?

詳細規格請參閱上方規格表;我們會按現場點位數量、距離及功率需求設計網絡架構,並提供整體方案報價。

安裝後有問題如何跟進?

原廠行貨保養,工程另設保養期;網絡設備我們會預先設定好即插即用,日後有問題可遠程協助或上門檢查。

60GHZ 定 80211AC 邊個好?

兩者主要規格分別:CABLE, UL POWER SUPPLY CORD SET, INDIA方面,60GHZ 係 V1000, V3000, N000900L012A V5000 V5000,80211AC 係 N000900L012;重量方面,60GHZ 係 0.18 Kg (0.39 lbs),80211AC 係 0.7 kg (1.5 lbs) without brackets;Temperature方面,60GHZ 係 0°C (32°F) to +50°C (140°F),80211AC 係 -30°C to +60°C (-22°F to 140°F) PAGE 1-7。實際邊個型號更適合,需視乎現場環境同需求而定,可先比較 80211AC 詳細規格,或直接聯絡我們免費現場評估,由工程師建議最合適方案。

60GHZ 保養、維修邊度做?

HKEZIT 提供 60GHZ 原廠行貨連保養,安裝後如有故障可直接聯絡我們安排上門維修,毋須自行聯絡原廠。詳情請參閱網絡 WiFi安裝工程頁面或聯絡我們查詢保養範圍。

香港安裝服務地區

HKEZIT 於全港各區提供 60GHZ Cambium 60 GHZ cnWave™供貨連專業安裝服務(裝WIFI、裝ROUTER、裝FIREWALL),熱門地區包括:中環網絡佈線 WiFi 工程九龍城網絡佈線 WiFi 工程九龍灣網絡佈線 WiFi 工程佐敦網絡佈線 WiFi 工程元朗網絡佈線 WiFi 工程北角網絡佈線 WiFi 工程土瓜灣網絡佈線 WiFi 工程大圍網絡佈線 WiFi 工程。港島、九龍、新界全港 32 區均有上門安裝,歡迎聯絡我們查詢 60GHZ 香港價格連安裝報價。

網絡 WiFi適用場景

60GHZ Cambium 60 GHZ cnWave™適合多種場景使用,以下為部分常見安裝場景,歡迎查詢是否適合您的現場環境。

查看更多網絡 WiFi適用場景,請參閱 網絡 WiFi安裝工程

相關產品

如需整套網絡 WiFi方案,請參閱 網絡 WiFi安裝工程

查詢 60GHZ 連安裝價格

免費上門評估,即日報價,原廠行貨保養