| Characteristic | Symbol Unit Condition |
|---|
| Min. | Typ. Max. Primary current, nominal measuring |
|---|
| IPN | A -1500 — 1500 — range (dc) |
|---|
| Supply voltage | VS V 6 12 18 — Supply voltage hysteresis: |
|---|
| maximum | VUP V — 18.5 — when VC increases |
|---|
| VUP | V — 18.0 — when VC decreases |
|---|
| minimum | VLOW V — 6.4 — when VC increases |
|---|
| VLOW | V — 5.9 — when VC decreases |
|---|
| Current consumption | IC mA 40 — 200 VS = 12 V, T = 25°C temperature range with |
|---|
| Ambient operating temperature | TA °C [°F] -40 [-40] — 85 [185] accuracy guaranteed T = -40°C to 85°C, |
|---|
| High precision channel offset at IP = 0 A | IOS A ±0.1 VS = 9 V to 16 V, ±3 sigma High precision channel total accuracy: |
|---|
| high at IP = 0 A to 20 A | IOS A -0.1 — +0.1 T = -40°C to 85°C, |
|---|
| high at 20 A < IP < 1500 A | XG — — ±0.5% of IP — VS = 9 V to 16 V, ±3 sigma Redundancy channel total accuracy: |
|---|
| low at IP = 0 A to 300 A | IOS A -15 — +15 T = -40°C to 85°C, |
|---|
| low at IP = 300 A to 1500 A | XG — — ±5% of IP — VS = 9 V to 16 V, ±3 sigma CSSV1500 Current Sensors Datasheet | sps.honeywell.com/ast | 2 TABLE 3. MECHANICAL SPECIFICATIONS |
|---|
| Housing material | PA66+GF25 (UL 94V - 0) M5, torque = 3,5 N m max. The installation bracket should have a flatness tolerance of ≤0,2 mm. The size tolerances of the |
|---|
| Mounting screws | installation bracket and nut, as well as the use of installation tools and fixtures, have an impact on the maximum installation torque of the product. If there are any relevant design or process changes, it is advisable to implement them after verification. |
|---|
| Mating electrical connector | TE MPN 1473672-1 |
|---|
| 重量 | 168 g ±5 g TABLE 4. CERTIFICATIONS |
|---|
| Automotive Safety Integrity Level | ASIL C |
|---|
| Pollution degree | PD2 |
|---|
| -1500 -1000 | -500 0 500 1000 1500 IP (A) CSSV1500 Series Current Sensors Datasheet | sps.honeywell.com/ast | 3 TABLE 5. ORDER GUIDE |
|---|
| Catalog Listing | Description CSSV1500N Series ASIL C current sensors, 1500 A, through-hole mounting with stainless steel CSSV1500N-154 bushing, 500 k baud rate, 3C4 CAN ID CSSV1500N Series ASIL C current sensors, 1500 A, through-hole mounting with stainless steel CSSV1500N-155 bushing, 500 k baud rate, 3C5 CAN ID CSSV1500N Series ASIL C current sensors, 1500 A, through-hole mounting with stainless steel CSSV1500N- |
|---|
| CS | S V 1500 N - 1 5 4 R |
|---|
| Rated | Fixture MCU Baud |
|---|
| 類型 | Principle Use CAN ID1 Customization |
|---|
| Current | Type Type Rate ASIL C |
|---|
| V Designed for | 1500 1500 A Through-hole 1 MCU1 5 500 k 4 3C4 R2 |
|---|
| vehicle | mounting with |
|---|
| applications | stainless 5 3C5 steel bushing 6 3C6 Custom CAN IDs are available. Contact Honeywell Customer Service for more information. Customization selection “R” indicates reverse current direction. CSSV1500 Current Sensors Datasheet | sps.honeywell.com/ast | 4 |
|---|
| Speed | See Figure 2 |
|---|
| Protocol | version 2.0A |
|---|
| Oscillator tolerance | 0.3125% |
|---|
| Byte order | big endian (Motorola) |
|---|
| StatusOutOf | StatusCurrent |
|---|
| Byte | SequenceCounterIP Error Information |
|---|
| RangeIndication | ValueIndication 0 7 6 5 4 3 2 1 0 1 15 14 13 12 11 10 9 8 2 23 22 21 20 19 18 17 16 3 31 30 29 28 27 26 25 24 4 39 38 37 36 35 34 33 32 5 47 46 45 44 43 42 41 40 6 55 54 53 52 51 50 49 48 7 63 62 61 60 59 58 57 56 |
|---|
| Signal Name | Description |
|---|
| SequenceCounterIP | Initial value is 0, plus 1 every frame. Reset to 0 when the counter reaches 14. 01: Power in Under Voltage, 10: Power in Over Voltage, 11: Internal Error, |
|---|
| ErrorInformation | 10 state, Current Value Output 0xFFFFFF/0xFFFF 11 state, Output Current value |
|---|
| StatusOutOfRange | 0: Normal, 1: Out of Measure Range |
|---|
| StatusCurrentValueInvalid | 0: Current Value is valid, 1: Current Value is invalid Unsigned number 24 bits, Unit: mA (offset 0x800000) When out of range occurs, becomes 0xFFFFFF, Ip_oc = 1550 A |
|---|
| -1500 ≤ Ip ≤ +1500 | signal = Ip accuracy = Spec |
|---|
| -Ip_oc ≤ Ip < -1500 | signal = Ip accuracy = ±2% (for reference) |
|---|
| +1500 < Ip ≤ Ip_oc | signal = Ip accuracy = ±2% (for reference) |
|---|
| Ip < -Ip_oc | signal = 0xFFFFFF accuracy = NA |
|---|
| Ip > Ip_oc | signal = 0xFFFFFF accuracy = NA Unsigned number 16 bits, Unit: A (offset 0x8000) When out of range occurs, becomes 0xFFFF, Ip_oc = 1550 A |
|---|
| Low Precision Current | -Ip_oc ≤ Ip < -1500 signal = Ip accuracy = ±10% (for reference) |
|---|
| Software Build | Software version 8 bit SAE J1850 CRC/AUTOSAR profile 1 DataId = Same as CAN ID; DataIdMode = E2E_P01_DATAID_BOTH CSSV1500 Series Current Sensors Datasheet | sps.honeywell.com/ast | 5 73,6 [2.90] 63,5 [2.5] ø24,22 [0.95] |
|---|
| [0.47] | 2X ø5,4 [0.21] 69,05 [2.72] [1.26] [1.22] 48,7 SEE DETAIL A |
|---|
| [1.92] | 29,8 [1.17] 6,45 [0.25] PINOUT 10,45 |
|---|
| Pin | Output [0.41] 1 CAN-L 2 CAN-H 3 GND 4 VS DETAIL A 2D Barcode includes: C S SV15 0 0 N -X X X : C ATALOG LISTING (E X AMPLE ) Y YDDD 0 0 N: SN CODE Y Y: PART PRODUCTION YE AR DDD: DAY OF THE YE AR 0 0 N: NUMBER (IN HE X ADECIMAL) OF DAILY PART PRODUCTION |
|---|
| All other versions | Customized version "R" CSSV1500 Current Sensors Datasheet | sps.honeywell.com/ast | 6 |
|---|
| Test Name | Standard Procedure According to CISPR 25:2008 Commission |
|---|
| CISPR 25 Conducted RF Emissions - Voltage | CISPR25 Form of Testing According to CISPR 25:2008 Commission |
|---|
| CISPR 25 Conducted RF Emissions - Current | CISPR25 Form of Testing According to CISPR 25:2008 Commission |
|---|
| CISPR 25 Radiated Emissions - ALSE Method | CISPR25 Form of Testing |
|---|
| Transient Conduction Emission | ISO 7637-2 According to ISO 7637-2 |
|---|
| Low Frequency Magnetic Field Emission | SAE J551-5 According to SAE J551-5 |
|---|
| Bulk Current Injection (BCI) Test | ISO 11452-4 According to ISO 11452-4 |
|---|
| Rf Anti-Interference - ALSE Method | ISO 11452-2 According to ISO 11452-2 |
|---|
| ISO 7637-3 | According to ISO 7637-3 |
|---|
| Low Frequency Field Interference | ISO 11452-8 According to ISO 11452-8 Unpowered direct contact discharge: ±15 kV Unpowered air discharge: ±15 kV |
|---|
| Electrostatic Discharge | ISO 10605 Powered-up direct contact discharge: ±8 kV Powered-up air discharge: ±15 kV |
|---|
| Portable Transmitter | ISO 11452-9 According to ISO 11452-9 10 V/m (80 MHz to 1 GHz), 3 V/m (1.4 GHz to |
|---|
| Radio Frequency Electromagnetic Field | IEC 61000-4-3 2 GHz), 1 V/m (2.0 GHz to 2.7 GHz) |
|---|
| Radio Frequency Continuous Conducted | IEC 61000-4-6 0.15 MHz to 80 MHz, 3 V 80% AM (1 kHz) |
|---|
| Radio Frequency Magnetic Field | IEC 61000-4-8 30 A/M CSSV1500 Series Current Sensors Datasheet | sps.honeywell.com/ast | 7 TABLE 10. ENVIRONMENTAL TEST SPECIFICATIONS |
|---|
| Low Temperature Storage | ISO16750-4 and VS nom. 48 hr, -40°C power off. Performance test before and after test at 25°C and |
|---|
| High Temperature Storage | ISO16750-4 VS nom. 120 cycles: one cycle contains -40°C (120 min soak) and 85°C (120 min |
|---|
| Thermal Cycle Test | ISO16750-4 soak). Transition time = 120 min. Performance test before and after test at 25°C and VS nom. |
|---|
| High Temperature and | 1000 hr, 85°C, 85% humidity, power on with 100 A primary current. ISO16750-4 |
|---|
| Humidity Endurance | Performance after test, from −40°C to 85°C, notify XG ≤1 % 5 Hz to 2000 Hz, 20 hr/axis, three axes with −40°C/85°C temperature |
|---|
| Vibration | IEC60068-2-64 cycle during test. Product power on with 100 A primary current. Performance test before and after test at 25°C and VS nom. 500 m/s, 2,20 each direction (60 total), half sine pulse. Product power |
|---|
| Mechanical Shock | ISO16750-3 on with 100 A primary current. Performance test before and after test at 25°C and VS nom. With final packaging, drop in direction at one corner, three edge, four ISTA-1A or GB/T |
|---|
| Package Drop | face > total nine drops, one m on concrete floor. Performance test before 4857.5 and after test at 25°C and VS nom. First fall of each DUT at a different dimensional axis. Second fall with the given DUT at the same dimensional axis but on the opposite side of the |
|---|
| Handling Drop | ISO 16750-3 housing, from 1 m on concrete floor. Performance test before and after test at 25°C and VS nom. Waterproof and Dust (and |
|---|
| ISO20653 | IP category: 40 other Solid Intrusion) CSSV1500 Current Sensors Datasheet | sps.honeywell.com/ast | 8 TABLE 11. ELECTRICAL TEST SPECIFICATIONS1 |
|---|
| Long Time Overvoltage Test | ISO 16750-2 Power supply at 18 V for 60 min. Test voltage UC max 16 V for 12 V systems; ac voltage (sinusoidal): |
|---|
| Superimposed Alternating Voltage | ISO 16750-2 Severity 2, UPP = 4 V Slow Decrease Fast Increase of |
|---|
| ISO 16750-2-4.5 | According to ISO 16750-2-4.5 testing standard and Fig Supply Voltage |
|---|
| Reset Behavior at Voltage Drop | ISO16750-2-4.6.2.2 See Fig. 6 |
|---|
| Transient Overvoltage Test | ISO16750-2 Power supply at 24 V for 10 min. |
|---|
| Momentary Drop in Supply Voltage | ISO 16750-2-4.6.1 U C min to 4.5 V. See Fig. 4 |
|---|
| Load Dump | ISO 16750-2-4.6.4 Pulse described in Table 6. See Fig. 9 |
|---|
| Reverse Voltage Test | ISO16750-2-4.7 Power supply at -24 V for 10 min. Connect sensor to 12 V power supply and power on the sensor. |
|---|
| Single Line Open Circuit Tests | ISO16750-2-4.9 Disconnect Us, GND, CAN-H, and CAN-L in sequence. Each open circuit time: 60 ±1 s Connect sensor to 12 V power supply and power on the sensor. |
|---|
| Connector Open Circuit Tests | ISO16750-2 Disconnect connector. Each open circuit time: 10 ±1 s |
|---|
| Insulation Resistance Test | ISO 16750-2-4.12 500 Vdc for 60 s; Resistance criteria: >500 MOhm Test Voltage: 5000 Vdc and ac. Frequency: dc and 50~60 Hz. Test |
|---|
| dc and ac Voltage Insulation Test | — Duration: 60 s See the applicable standard for all table and figure references. CSSV1500 Series Current Sensors Datasheet | sps.honeywell.com/ast | 9 |
|---|
| NOTICE | m WARNING |
|---|
| PRELIMINARY | Honeywell warrants goods of its PERSONAL INJURY manufacture as being free of defective |
|---|
| DOCUMENTATION | DO NOT USE these products as safety |
|---|
| materials and faulty workmanship | or emergency stop devices or in any The information contained in this |
|---|
| during the applicable warranty period. | other application where failure of the document is preliminary and for |
|---|
| reference only. Preliminary means | Honeywell’s standard product warranty product could result in personal injury. |
|---|
| that the product described has not | applies unless agreed to otherwise by Failure to comply with these |
|---|
| been or is currently being formally | Honeywell in writing; please refer to instructions could result in death or |
|---|
| tested. Specifications are subject to | your order acknowledgment or consult serious injury. change without notice. Reliance on the your local sales office for specific information contained herein is at the warranty details. If warranted goods reader’s own risk. are returned to Honeywell during the m WARNING |
|---|
| period of coverage, Honeywell will | MISUSE OF |
|---|
| repair or replace, at its option, without | DOCUMENTATION |
|---|
| charge those items that Honeywell, | • The information presented in this |
|---|
| in its sole discretion, finds defective. | product sheet is for reference only. Do not use this document as The foregoing is buyer’s sole remedy a product installation guide. |
|---|
| and is in lieu of all other warranties, | • Complete installation, operation, |
|---|
| expressed or implied, including those | and maintenance information |
|---|
| of merchantability and fitness for a | is provided in the instructions |
|---|
| particular purpose. In no event shall | supplied with each product. |
|---|
| Honeywell be liable for consequential, | Failure to comply with these |
|---|
| special, or indirect damages. | instructions could result in death or serious injury. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer’s sole responsibility to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is |
|---|
| For more information | believed to be accurate and reliable |
|---|
| Honeywell Sensing & Safety | as of this writing. However, Honeywell |
|---|
| Technologies services its customers | assumes no responsibility for its use. |
|---|
| USA/Canada | +1 302 613 4491 |
|---|
| Latin America | +1 305 805 8188 |
|---|
| Europe | +44 1344 238258 |
|---|
| Japan | +81 (0) 3-6730-7152 |
|---|
| Singapore | +65 6355 2828 |
|---|
| Greater China | +86 4006396841 006007-4-EN | 4 | 01/24 |
|---|
| www.honeywell.com | © 2024 Honeywell International Inc. All rights reserved. |
|---|